5334V110-UK
5
Effect of supply voltage variation .................... < 0.005% of span / VDC
Vibration ...................................................................... IEC 60068-2-6 : 2007
2...25 Hz .................................................................. ±1.6 mm
25...100 Hz ............................................................ ±4 g
Max. wire size ............................................................ 1 x 1.5 mm
2
stranded wire
Screw terminal torque ........................................... 0.4 Nm
Humidity ...................................................................... < 95% RH (non-cond.)
Dimensions ................................................................. Ø 44 x 20.2 mm
Protection degree (enclosure / terminal) ....... IP68 / IP00
Weight .......................................................................... 50 g
Electrical specifications, input:
Max. offset ................................................................. 50% of selec. max. value
TC input:
Basic values
Input type
Basic
accuracy
Temperature
coefficient
Volt
≤
±10 µV
≤
±1 µV / °C
TC type:
E, J, K, L, N, T, U
≤
±1°C
≤
±0.05°C / °C
TC type: B, R, S,
W3, W5, LR
≤
±2°C
≤
±0.2°C / °C
EMC immunity influence ................................................ < ±0.5% of span
Extended EMC immunity:
NAMUR NE
21, A criterion, burst ............................... < ±1% of span
Type
Min.
temperature
Max.
temperature
Min.
span
Standard
B
E
J
K
L
N
R
S
T
U
W3
W5
LR
+400°C
-100°C
-100°C
-180°C
-100°C
-180°C
-50°C
-50°C
-200°C
-200°C
0°C
0°C
-200°C
+1820°C
+1000°C
+1200°C
+1372°C
+900°C
+1300°C
+1760°C
+1760°C
+400°C
+600°C
+2300°C
+2300°C
+800°C
100°C
50°C
50°C
50°C
50°C
50°C
100°C
100°C
50°C
50°C
100°C
100°C
50°C
IEC584
IEC584
IEC584
IEC584
DIN 43710
IEC584
IEC584
IEC584
IEC584
DIN 43710
ASTM E988-90
ASTM E988-90
GOST 3044-84