SyMBOL IDENTIFICATION

 

Triangle with an exclamation mark:

 Warning / demand. 

 

Potentially lethal situations.

 The 

CE mark

 proves the compliance of the device with the essential

 

requirements of the directives.

 

 The 

double insulation

 symbol shows that the device is protected by

 

 

double or reinforced insulation.

 

 

Ex devices

 have been approved for use in connection with

 

 

installations in explosive areas.

SAFETy INSTRUCTIONS

DEFINITIONS
Hazardous voltages

 have been defined as the ranges: 75 to 1500 Volt DC, and 

50 to 1000 Volt AC.

Technicians 

are qualified persons educated or trained to mount, operate, and also 

troubleshoot technically correct and in accordance with safety regulations.

Operators

, being familiar with the contents of this manual, adjust and operate the 

knobs or potentiometers during normal operation.

RECEIPT AND UNPACKING

Unpack the device without damaging it. The packing should always follow the 
device until this has been permanently mounted. Check at the receipt of the device 
whether the type corresponds to the one ordered.

ENVIRONMENT

Avoid direct sunlight, dust, high temperatures, mechanical vibrations and shock, as 
well as rain and heavy moisture. If necessary, heating in excess of the stated limits 
for ambient temperatures should be avoided by way of ventilation.
All devices fall under Installation Category II, Pollution Degree 1, and Insulation 
Class II.

MOUNTING

Only technicians who are familiar with the technical terms, warnings, and 
instructions in the manual and who are able to follow these should connect the 
device.

Summary of Contents for 5131A

Page 1: ...5 1 3 1 P r o g r a m m a b l e T r a n s m i t t e r N o 5 1 3 1 V 1 0 4 U K S e r n o 0 4 0 1 1 2 0 0 1 1 9 1 0 9 1 0 0 0...

Page 2: ...electronics A S offre une large gamme de produits pour le traite ment des signaux analogiques et num riques dans tous les domaines industriels La gamme de produits s tend des transmetteurs de temp rat...

Page 3: ...identification 3 Safety instructions 3 How to demont system 5000 5 Application 6 Technical characteristics 6 Input types 6 Output 7 Sensor error detection 7 Configuration 7 Electrical specifications 8...

Page 4: ...rer the protection provided by the equipment may be impaired WARNING Until the device is fixed do not connect hazardous voltages to the device The following operations should only be carried out on a...

Page 5: ...y regulations Operators being familiar with the contents of this manual adjust and operate the knobs or potentiometers during normal operation Receipt and unpacking Unpack the device without damaging...

Page 6: ...ff the voltage to the device Production year can be taken from the first 2 digits of the serial number Calibration and Adjustment During calibration and adjustment the measuring and connection of exte...

Page 7: ...rail as shown in picture 1 Then by lifting the upper lock and pulling the front plate simultaneously the PCB is removed as shown in picture 2 Switches and jumpers can now be adjusted By opening the fr...

Page 8: ...aracteristics The unit is based on a microprocessor core with an efficient program operation The basic calibration data and present set up are stored in an EEPROM thereby avoiding the loss or change o...

Page 9: ...Standard loop 4 20 mA current output The output signal is proportional and linear to the value of the input signal Special set ups can be selected in the configuration program for instance a customis...

Page 10: ...rface Loop Link Signal noise ratio Min 60 dB 0 100 kHz Signal dynamics input 22 bit Signal dynamics output 16 bit Updating time Temperature input 115 ms mA V mV input 75 ms Response time 0 90 100 10 p...

Page 11: ...109 x 23 5 x 130 mm DIN rail type DIN 46277 Protection degree IP20 Weight 195 g EMC immunity influence 0 5 of span Extended EMC immunity NAMUR NE 21 A criterion burst 1 of span Basic values Input type...

Page 12: ...of sensor cable resistance 3 4 wire 0 002 Sensor error detection Yes Type Min value Max value Min span Standard Pt100 Ni100 Lin R 200 C 60 C 0 850 C 250 C 5000 25 C 25 C 30 IEC 751 DIN 43760 Type Min...

Page 13: ...C Max offset 50 of selec max value Input resistance 2 5 VDC Nom 10 M 2 5 VDC Nom 5 M Electrical specifications OUTPUT Signal range span 4 20 mA Min signal range span 10 mA Max offset 50 of selec max v...

Page 14: ...D 2006 95 EC EN 61010 1 PELV SELV IEC 364 4 41 and EN 60742 ATEX 94 9 EC EN 50014 EN 50020 and EN 50281 1 1 Of span Of the presently selected range Order Note For TC inputs with internal CJC remember...

Page 15: ...Pt100 DIN IEC 0 00 50 00C 3 wire 1 00sec Inputrange C onnection C old junction comp Response time Tag no Disconnectwhen online loopcommunicationisused Loopcommunication Vsupp Black Red Yellow Green 4...

Page 16: ...4 20 m A 0 16 m A 0 16 m A 53 5 M 52 Input Input 2 5 V Channel 2 Channel 1 mV TC Front comm Front comm RTD and lin R Conn wire Input gnd Analogue switch Analogue switch Accessories 5910 CJC connector...

Page 17: ...lvanic isolators for analog and digital signals as well as HART signals A wide product range with both loop powered and universal isolators featuring linearization inversion and scaling of output sign...

Page 18: ...it prelectronics com www prelectronics se sales se prelectronics com www prelectronics co uk sales uk prelectronics com www prelectronics com sales us prelectronics com www prelectronics cn sales cn...

Reviews: