Fixed Installations
The units must be installed by a qualified Electrician in accordance with current I.E.E. Wiring
Regulations or, where these do not apply, in accordance with applicable Local Wiring Regulations.
•
Select a suitable location that is away from doors, windows air-conditioning vents, is not beneath
pipe work on which condensation forms and allows free air-flow all around the unit.
•
It is recommended that if possible the base of the unit should be at least 2mtrs above the level of
the floor.
Programming the Unit
Control Panel
The Multi-Scent
1 is equipped with 1 fragrance cartridge “channel” that can be operated.
The Multi-Scent
2 is equipped with 2 fragrance cartridge “channels” that can be operated
independently of each other or simultaneously in order to alternate fragrance type in a single unit or
boost the overall intensity of a single fragrance.
The Multi-Scent
3 is equipped with 3 fragrance cartridge “channels” that can be operated
independently of each other or simultaneously in order to alternate fragrance type in a single unit or
boost the overall intensity of a single fragrance.
Whilst each channel can be operated independently, the Fragrance Intensity, Fan Speed and
Day/Night/24hour option settings are common to all three “channels”.
The programmability of Multi-Scent
systems is designed to enable the user to match fragrance intensity and
dispersal to room volume and location requirements. A certain amount of trial and error may be required
and it is always advisable to begin with lower intensity and fan speed settings increasing these until the
desired intensity and dispersal are achieved. (It should be noted that fragrance dispersal is not
instantaneous and that the unit should be left to operate for 15-30 minutes before adjustments are made).
Intensity Control
Cartridge Usage
Indicators
Fan Output Speed
Power On Indicator
On / Off
Switches
Day/Night
24 Hour Selector