background image

 

 
Rear View 
 

a)

 

LED light 

 ON/OFF Switch 

b)

 

Inverter 

 Switch on to use inverter output 

c)

 

12VDC Socket 

 For connecting 12VDC appliances/loads up to 144W (rated at 12A- Non 

regulated). Also used with lighting adapter. (See Section 4 a) 

d)

 

Inverter Green LED light- Indicates Inverter is ON 

e)

 

Battery Low Green LED light 

 Indicates Internal battery (or internal and external if 

connected) is low. 

f)

 

Load 80% red LED light 

 Indicates inverter is at 80% of max rating (400 watts) 

g)

 

Charging Red LED light 

 Indicates the batteries are being charged either from the AC 

charger or from solar panel input 

h)

 

100% Green LED light 

 Indicates the batteries are fully charged 

i)

 

Charger Input 

 connection for AC charger. Only suitable to charge internal battery. 

 

                                                   

                                                                                     

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for Powerpack 400

Page 1: ...1 PPT Powerpack 400 User Manual Please Read this Manual carefully before using ...

Page 2: ...fully before use and retain them for future reference If any modification is made it may damage the product and void any warranty Content 1 Introduction and Overview 3 2 Features and Functions 4 3 Using the Power Inverter Function 7 4 Using the Supplied Accessories 7 5 Maintenance and Warnings 8 6 Warranty 9 7 Troubleshooting 9 8 Contact 9 ...

Page 3: ...tery Fuse This can be found by sliding down the side panel Then clip on fuse covers supplied in bag over each fuse marked Internal and External Specifications Inverter Output Power 400W Inverter Output Voltage 230Vac AC outlet 1 x universal socket DC outlet 12Vdc 10A unregulated USB outlet 5V 1A Battery 18AH SLA Battery Solar Regulator 10A Fuses 40A blade Dimensions W 410 D 110 H 370mm Weight 12KG...

Page 4: ... ON position b USB Output Connect a USB cable not supplied to charge mobile phones and other portable devices c Battery Check Press the black switch to check the battery status The coloured LED s light up accordingly to show the battery status d 2 Watt LED Light Integrated to front panel ON OFF switch on rear side ...

Page 5: ...Inverter is ON e Battery Low Green LED light Indicates Internal battery or internal and external if connected is low f Load 80 red LED light Indicates inverter is at 80 of max rating 400 watts g Charging Red LED light Indicates the batteries are being charged either from the AC charger or from solar panel input h 100 Green LED light Indicates the batteries are fully charged i Charger Input connect...

Page 6: ...s 3 pin input connector as supplied with PPT Powerpack 400 The maximum input is 10 Amps See Section 3 b 2 for more info c External Battery Fuse Protects external batteries if connected d Internal Battery Fuse Protects internal battery NOTE This fuse must be inserted for the unit to operate properly e EXT Battery External battery connection Using the supplied cable a further external battery can be...

Page 7: ...he supplied lighting adapter is designed for connection to the 12VDC socket See section 2 2 c to provide simple and safe connection of lights to the PPT Powerpack 400 The Lighting Adapter will accommodate up to five of the PPT light strips These LED light strips are supplied separately and are available to order from Portable Power Technology The 30 LED light strips are designed at 7 Watts each to...

Page 8: ...ernal battery of the powerpack 400 is 18AH By connecting a further battery using the External battery cable essentially puts this battery in parallel to it to further increase the AH rating eg Internal battery 18AH External battery 60AH 78AH The connection to the external battery is made using the supplied cable One end is terminated with a large connector that connects to the EXT Battery connecto...

Page 9: ...et the switch inverter OFF then ON again Battery not charging Check connection to solar panel AC charger Check external battery fuse Unit is clicking when AC charger is connected or solar panel is connected Check internal battery fuse see section 2 4d Unit has been left on and is fully discharged the unit will not recharge Connect external battery cable to a known charged battery Leave 10 mins Dis...