PPG SEMKIT Use Instruction Download Page 1

1.    Wear safety glasses, gloves and  
other appropriate protection during  
all operations.  Review the relevant  
Technical Data Sheet (TDS) and    
Safety Data Sheet (SDS) before using  
any chemicals. Contact your site 
Health and Safety supervisor for more 
details on appropriate PPE and safety  
precautions. 
 

2.    For optimum mixing properties and
ease of mixing, the kit should be condi-
tioned at 70 °F ± 5 °F (21 °C ± 3 °C) prior to
mixing and use. When not in use, the kit
should be stored as directed on the prod-
uct label or relevant material specification 
to ensure retention of properties and
maintain the product certification. Store 
the kit in the upright position to minimize 
the potential for leakage. Do not open 
or puncture the outer Mylar

®

 bag until 

the cartridge is ready to be mixed. The 
outer Mylar

®

 bag is purged with an 

inert atmosphere which preserves the 
cartridge during storage.

 
3.    Inspect the label on the bag and 
verify that the shelf life is within the listed 
expiration date. Verify that the sealant is 
the correct product for your application. 
Open the outer Mylar

®

 bag and gently 

empty the contents of the bag. The bag 
may contain a glass vial of adhesion  
promoter if required for use with the 
sealant; take care not to damage or break 
the glass vial. 

4.    Hold the cartridge firmly in one 
hand, with your other hand holding the 
dasher rod handle.  Pull the dasher rod  
forward approximately 1/4 of the way 
up the cartridge (away from the plunger 
so that the dasher rod is not in contact 
with the plunger).

5.    Insert the ramrod into the hollow  
hole in the handle of the of dasher rod;  
push the dasher rod so that it moves 
the dasher piston, and inject approxi-
mately 1/3rd of the contents of the dasher 
rod (accelerator component) into the 
cartridge. 

    
  
  

CAUTION: 

Use firm but even pressure 

when pushing the ramrod Do not use 
excessive force, tap, pound, or jolt the 
ramrod if the piston does not move 
readily. The dasher piston may be difficult 
to move at first, but will move with 
continued even force from the ramrod.  
 

6.    Repeat steps 3 and 4, working your  
way up the cartridge and advancing  
the dasher rod toward the neck end of 
the cartridge until all of the contents are 
emptied into the cartridge, so that the 
accelerator is injected in approximately 
1/3rd intervals throughout the cartridge. 
Do not inject all of the accelerator at 
once or in one area, as this will lead 
to a non-uniform mix, and may impact 
application and performance properties 
of the sealant.  

Catalyst in dasher rod with base in cartridge 

Step 3

Step 4

Step 5 A

Base

Accelerator

Semkit components

Step 5 B

Injection style PPG SEMKIT

®

 package

Manual use instructions  

Step 6 A, B, C

Reviews: