Parameter Description 

(c)

P04) 

Select degrees Celsius (°C) or Fahrenheit (°F).

P05) T/C Type

 - Select thermocouple types J or K.

P06) Over-temp. Alarm Limit 

- Alarm when process temp. is over setpoint value as set 

in parameter.

P07) Under-temp. Alarm Limit 

 - Alarm when process temp. is under setpoint value as 

set in parameter.

P08) T/C Pinched

 - Time, in seconds, that the controller will take to detect a pinched or 

shorted thermocouple. (There is current, no rise in temperature)

P09) Open TRIAC/Heater 

- Time, in seconds, that the controller will take to detect an 

open TRIAC, open heater, or open wire. (No current and no rise in temperature)

P10) APO Enable

 - In the event of a T/C break and the controller is at set point, the 

controller uses the last average output power (APO) to maintain temperature. (Automatic 
Bumpless Transfer). T/C must be repaired as soon as possible.

P11) Boost Time setting

 - Time (in seconds) desired for boost mode.

P12) Auto Mode Boost Temp.

 - Boost temperature over setpoint. (Boost temp. + set-

point)

P13) Manual Mode Boost Power

 - Manual percentage power output during boost mode 

for a set time (P15).

P14) Manual Mode Standby Power

 - Manual percentage power output during standby 

mode.

P15) Auto Mode Standby temp.

 - Standby/idle setpoint value.

P16) Soft-Start Time

 - Time duration, in minutes, that the controller is in Soft-Start. 

(Bake Out)

P17) Soft-Start Lock

 - Prevents users from changing mode while in soft-start.

P18) Audible Alarm Enable/Disable

 - controller audible alarm.

P19) Keypad Lock

 - 

YES:

 Disables all keys, except for the *PMTR* key, to prevent 

unwanted changes. 

NO:

 All keys enabled.

P20) Frequency

 - AC line frequency (Display only).

P21) Tuning Stabilization

 - Adjustment for heaters with lagging thermocouple or low 

mass (quick heat dissipation heaters). If there is fl uctuation of temperature, adjust higher 
(recommended maximum of 75).

7

Summary of Contents for BTC15

Page 1: ...44056 U S A 216 367 7000 Toll Free 800 321 0562 Fax 216 367 7022 Order Fax 800 223 8305 6385 Montessouri Street Las Vegas Nevada 89113 702 433 6385 800 258 8877 Fax 702 433 6388 11218 Challenger Avenue Odessa Florida 33556 727 834 8888 800 282 6783 Fax 727 834 8873 www ppe com e mail sales ppe com PPE WEST PPE SOUTH Toll Free USA Canada Mexico 800 362 0706 ...

Page 2: ...incorrect fuse type is used application of High Voltage rated over the system s required specifications or application of High Voltage to thermocouple inputs PPE accepts no responsibility or liablity for the APPLICATION by the customer of temperature controllers This liability is assumed by the customer Upon inspection if the returned product does not meet our warranty requirements customer may be...

Page 3: ... displayed When decimal is lit temp is displayed in Celsius User Input Keypad Mode Indicator LEDs SOFT Soft Start MAN Manual Open loop AUTO Auto Closed loop STBY Standby Mode BST Boost Mode Up down keys For adjustment of setpoint parameters Mode Select key Manual Auto Standby and Boost Parameter key Scroll through parameters Enter key Save changes Amps Volt key View Current and voltage Figure 1 Co...

Page 4: ...he desired temperature then press ENTER The minimum and maximum values for temperature and setpoint are 32 999 Fahrenheit 5 650 Celsius Mode There are 4 running modes available manual open loop automatic closed loop standby idle and boost A solid lit LED indicates the mode the controller is in To change mode Press the MODE SELECT key until the blinking LED is over the desired mode then press the E...

Page 5: ...meter P12 MANUAL BOOST controller goes to the preset power set in parameter P13 Controller will remain in BOOST mode until preset time has elapsed set in parameter P11 Error Reset Upon detection of TOH TSH or HIA the controller must be powered off then on to clear the error once the issue has been corrected Refer to Pg 8 for error codes Parameter Changes 1 Press the PMTR key until the desired para...

Page 6: ...Temperature 5 250 Fahrenheit 5 120 Celsius 75 P13 Manual Boost Power 5 100 25 P14 Manual Standby Power 5 100 10 P15 Standby Temperature 50 350 Fahrenheit 50 175 Celsius 250 P16 Soft Start Time 0 20 minutes 5 P17 Soft Start Lock YES or NO YES P18 Audible Alarm YES or NO YES P19 Keypad Lock YES or NO NO P20 Frequency Hertz DISPLAY ONLY P21 Tune Stabilization 50 100 60 P01 Auto Power On After a power...

Page 7: ... T C must be repaired as soon as possible P11 Boost Time setting Time in seconds desired for boost mode P12 Auto Mode Boost Temp Boost temperature over setpoint Boost temp set point P13 Manual Mode Boost Power Manual percentage power output during boost mode for a set time P15 P14 Manual Mode Standby Power Manual percentage power output during standby mode P15 Auto Mode Standby temp Standby idle s...

Page 8: ... inserting into mainframe Display Codes Displayed on PRT process temperature display Display Code Description Explaination Hi High Temperature Process temp over setpoint value Lo Low Temperature Process temp under setpoint value OTC Open Thermocouple Thermocouple is open or break RTC Reverse Thermo couple Thermocouple wire reversed PTC Pinched Thermo couple Thermocouple has been shorted pinched TO...

Reviews: