3
INSTALLATION LOCATION
The location where the barrier will be installed must be previously analyzed,
including the entire site infrastructure, floor conditions, electrical power
supply, passageway width, ceiling height (if any), vehicle flow and the need
to use optional accessories.
Once it is analyzed, the equipment that best fits the needs of the place
should be chosen.
NOTE:
Using articulated barriers is usually recommended in places with
low ceilings. In this case, contact the factory to have a barrier with the
proper size for installation in the specific location supplied.
IMPORTANT
Check if any obstacles could interfere with the complete barrier
opening and closing. If so, the equipment installation will be impaired,
and repairs to the local infrastructure will be necessary. Carefully
choose the model according to its technical features and where it will
be installed. Notice the need for optional accessories. Calculate the
flow of vehicles on site.
NOTE:
If the floor does not meet the above specifications, a concrete
base plate respecting the cabinet base dimensions must be provided to
fix the cabinet. The concrete base plate should be installed at a minimum
height of 100 mm from the ground.
Preparing the location:
1. Run a 3/4" conduit pipe through the floor or concrete base plate from
the center of the base to the circuit breaker box installed from where the
equipment's electrical supply will come.
2. Run the power and pushbutton cables through this pipe to where the
equipment will be operated. Check the table below to choose the cables
according to the NBR 5410 standard.
TABLE OF CONTENTS
Installation location .......................................................................................................................................................................................................3
General features................................................................................................................................................................................................................4
Technical Specifications ............................................................................................................................................................................................5
Equipment dimensions ..............................................................................................................................................................................................5
Building the base plate to install the cabinet .........................................................................................................................................6
Installing the barrier .....................................................................................................................................................................................................7
Balancing the barrier and checking the belt ........................................................................................................................................12
Adjusting the magnet bars ..................................................................................................................................................................................13
Operation ............................................................................................................................................................................................................................14
TRIFLEX CONNECT AC control board ..................................................................................................................................................14
Encoder system (Digital Reed) .........................................................................................................................................................................14