F10R REFLECTIVE PHOTOCELL DETECTOR

INSTRUCTION MANUAL

COMFORT AND SECURITY

INSTALLATION

X

F10R Reflective 

photocell detector

PHOTOCELL DETECTOR FEATURES:

P04985 - Rev. 2

PRECAUTIONS

SPECIFICATIONS

- Max range: 08 meters (~26.25 feet) 

- Operating voltage: 12Vdc - 24Vdc;

- Current drain: 80mA;

- NO and NC outputs;

- Immediate triggering;

- Pulsed output for PPA Control boards.

Round Reflector

Connection terminal

( + ) ( - ):

 The device must be powered 

by a 12Vdc - 24Vdc auxiliary power 

supply;

P:

 Pulsed output for PPA Control 

boards;

NA, C and NF: 

Relay dry contact 

outputs. Used for circuit keying 

when the photocell is used in 

normal mode, either open or closed.  

Step 1: Attach the photocell detector the same side the control 

board is installed, since it will both receive commands from it and 

power it up. The receiver is attached the opposite side, with the 

transmitter and receiver facing each other. When attaching the 

round reflector, mind the (Installation) Position Indicator, it must 

face up.

 (    ). The photocell detector must be attached so 

that the opening for the wiring faces down, in order to 

avoid accidental water entering.

A installation diagram can be seen on the previous page. 

- Make sure the 

wiring is facing down;

- Install the photocell 

away from obstacles 

which could block the 

beam.

LED Indicator

Transmitter

Receiver

Wiring

Position indicator

(for installation)

The height indicated by an “X” refers to the height of the 

possible objects which will be detected by the device, such as 

vehicles, people and pets. For example, for a 50cm (~1.65f) high 

vehicle, the photocell detector must be installed over this 

height, otherwise it will not detect the vehicle. One must 

observe the minimum height (30 cm - ~0.99f), in order to both 

ensure a proper operation and avoid false alarms.

Note:

 There is no maximum height for installing the photocell 

detector.