![PPA DZ 1500 Technical Manual Download Page 7](http://html1.mh-extra.com/html/ppa/dz-1500/dz-1500_technical-manual_1592703007.webp)
7
6 - REQUIRED TOOLS FOR INSTALLATION
Below are some tools necessary to install the operator:
PLIERS
SAW
NUT DRIVER
SCREWDRIVER
FIXED WRENCH
STAIRS
SQUARE
DRILL
PENCIL
SANDER
WELDING MACHINE
HAMMER
LEVEL
MEASURING TAPE
7 - ELECTRICAL INSTALLATION
This equipment must be wired with 120V as specified in the table below (assuming max current consumption).
IMPORTANT
Be sure that the circuit breaker in the electrical panel is in the OFF
position before proceeding with the installation.
A separated power disconnect switch may be needed in your area.
Check your local building codes before installing this equipment.
The gate operator must be properly grounded, check your local
electrical codes before installing this equipment.
Install the earth ground rod as near as possible to the operator.
AC power
Wire Size (American Wire Gauge) / Max Distance in Feet
DZ PREDIAL
DZ CONDOMINIUM
DZ 1500
14 AWG
12 AWG
14 AWG
12 AWG
14 AWG
12 AWG
120 VAC Single Phase
115
182
115
182
64
101