4.Keyboard Description

Diagram 4-1:Operation panel display

4.1 Keyboard Indicators

Indicator flag

Name

St

at

us

la

m

p

RUN

Running indicator light

*ON: the inverter is working *OFF: the inverter is stops

LOCAL/

REMOTE

Command indicator light ,That is the indicator for keyboard operation,

terminal operation and remote

operation(communication control)

*ON: terminal control working status

*OFF: keyboard control working status

*Flashing: Remote control working status

FWD/REV

Forward/reverse running light

*ON: in forward status *OFF: in reversal status

TUNE/TC

Motor self-learning/Torque control/Fault indicator

*Slow flashing: in the motor tunning status

*Quick flashing: in the fault status

U

ni

ts

C

om

bi

na

tio

n

in

di

ca

to

r

HzAV

Hz

Frequency unit

A

Current unit

V

Voltage unit

RPM

Speed unit

%

Percentage

4.2 Description of operation panel keys

Sign

Name

Function

Parameter

Setting/Esc

Key

* Enter into the modified status of main menu

* Esc from functional parameter modification

* Esc submenu or functional menu to status menu

Shift Key

* Choose displayed parameter circularly under running or stop

interface; choose parameter’s modified position when modify parameter.

Increasing Key

* Parameter or function number increasing, set by parameter F6.18.

Decreasing Key * Parameter or function number decreasing, set by parameter F6.19.

Running Key

* For starting running in the mode of keyboard control status.

Stop/Reset Key * For stopping running in the running status; for resetting the operation

in the fault alarm status .the function of the key is subject to F6.00

Enter Key

* Enter the menu screen step by step, set the parameter confirmation

Quick

Multifunction

Key

*This key function is determined by the function code F6.21

Keyboard

Encoder

* F0.03 setting to 4, and the keyboard potentiometer setting the

operating frequency.

5.Standard specifications

Items

Specifications

Po

w

er

In

pu

t

Rated voltage

AC 1PH 220V(-15%)

220V(+10%)

AC 3PH 220V(-15%)

220V(+10%)

AC 3PH 380V(-15%)

380V(+10%)

AC 3PH 480V(-10%)

480V(+10%)

Input AC voltage

frequency

50Hz/60Hz

Allowing DC

voltage fluctuations

G1/G2

DC 150

450V

G3

DC 250

800V

G4

DC 400

900V

C

on

tro

ls

ys

te

m

Control system

High performance vector control inverter based on DSP

Control method

V/F control, vector control W/O PG

Automatic torque

boost function

Realize low frequency (1Hz) and large output torque control under the V/F

control mode.

Acceleration/deceler

ation control

Straight or S-curve mode. Four times available and time range is

0.0~6500.0s.

V/F curve mode

Linear, square root/m-th power, custom V/F curve

Over load capability

G type: rated current 150% - 1 minute, rated current 180% - 2 seconds

Maximum frequency

1.Vector control:0~300Hz;

2.V/F control:0~3200Hz

Carrier Frequency

0.5~16kHz; automatically adjust carrier frequency according to the load

characteristics.

Input frequency

resolution

Digital setting: 0.01Hz Analog setting: maximum frequency×0.025%

Start torque

G type: 0.5Hz/150% (vector control W/O PG)

Speed range

1:100 (vector control W/O PG)

Steady-speed precision Vector control W/O PG: ≤ ± 0.5% (Rated synchronous speed)

Torque response

≤ 40ms (vector control W/O PG)

Torque boost

Automatic torque boost; manual torque boost 0.1%~30.0%

Jogging control

Jog Frequency Range: 0.00Hz~max. frequency;

Jog Ac/deceleration time: 0.0s~6500.0s

Summary of Contents for PI500A-S 004G1

Page 1: ...PI500A S Series Special Solar Inverter For Water Pump English Manual www powtran com...

Page 2: ...y period please fill out the warranty card and fix it to our authorized dealer 2 Instructions on nameplate Model Designation Powtran Inverter PI 500A S 2R2 G 3 Rated Output Power 2R2 2 2kW 004 4kW Ser...

Page 3: ...63 185 90 146 154 65 174 5 72 5 1 6 PI500A S 0R7G2 0 75 PI500A S 1R5G2 1 5 PI500A S 2R2G2 2 2 163 185 90 166 174 65 174 5 72 5 1 8 PI500A S 004G2 4 238 260 120 182 190 90 250 5 2 7 PI500A S 5R5G2 5 5...

Page 4: ...ey is subject to F6 00 Enter Key Enter the menu screen step by step set the parameter confirmation Quick Multifunction Key This key function is determined by the function code F6 21 Keyboard Encoder F...

Page 5: ...panel control terminals and serial communication port They can be switched through a variety of ways Frequency source Total 8 frequency sources digital analog voltage multi speed and serial port They...

Page 6: ...ments of all terminals select accessories correctly such as voltmeter input power supply etc 5 Please check the wiring correctly after completion and power on after confirmation 7 The load is a single...

Page 7: ...motor nameplate Note If the starting current is too large or the motor does not run check whether the V and W phases are connected then check E8 29 3 and then restore the factory value y0 00 3 U V W...

Page 8: ...24 HDI DI5 pulse frequency HDI DI5 High speed pulse input frequency display unit 1Hz 1Hz d0 25 Communication set value Frequency torque or other command values set by communication port 0 01 d0 27 Mas...

Page 9: ...cked at the time the parking process of motor is not controlled by the inverter This way is same as the principle of free stop described in F3 07 9 Fault reset RESET The function makes use of terminal...

Page 10: ...to the function code F7 26 F7 27 s instructions 26 Frequency 1 reaches output Please refer to the function code F7 28 F7 29 s instructions 27 Frequency 2 reaches output Please refer to the function c...

Page 11: ...0 F4 10 V F overexcitation gain 0 200 80 F4 11 V F oscillation suppression gain 0 100 0 F4 12 V F Separated voltage source 0 9 0 F4 13 Voltage Digital Setting 0V motor rated voltage 0V F4 14 Voltage r...

Page 12: ...eleration time 2 0 00Hz F0 19 Maximum frequency 0 00Hz F7 15 Switching frequency point between deceleration time 1 and deceleration time 2 0 00Hz F0 19 Maximum frequency 0 00Hz F7 16 Forward reverse r...

Page 13: ...momentary power cut 0 00s 100 00s 0 50s F8 29 Judgment voltage of momentary power cut action 50 0 100 0 Standard bus voltage 80 F8 30 Load drop protection selection 0 Invalid 1 Valid 0 F8 31 load drop...

Page 14: ...valid after E0 03 awakens the delay time frequency inverter to start E0 04 Upper limit of MPPT search voltage 0 0 1000 0V Confirmed model typ Search value of upper limit voltage in MPPT search proces...

Page 15: ...tion Same as E1 19 0 E1 34 8 stage running time T8 0 0s h 6500 0s h 0 0s h E1 35 8 stage ac deceleration time selection Same as E1 19 0 E1 36 9 stage running time T9 0 0s h 6500 0s h 0 0s h E1 37 9 st...

Page 16: ...motor 0 b0 01 Rated power 0 1 1000 0kW Confirmed model typ b0 02 Rated voltage 1 2000V Confirmed model typ b0 03 Rated current 0 01A 655 35A Inverter power 55kW 0 1A 6553 5A Inverter rate 55kW Confirm...

Page 17: ...15 Current of the second fault y1 16 Bus voltage of the second fault y1 17 Input terminal status of the second fault y1 19 Output terminal status of the second fault y1 20 Power on time of the second...

Page 18: ...s high 1 Cancel the external force or install braking resistor 2 Set the voltage to the normal range 8 Err 08 Control power failure 1 The range of input voltage is not within the specification 2 frequ...

Page 19: ...an the set value of E2 11 Check PID feedback signal or set E2 11 to an appropriate value 40 Err 40 Quick current limiting fault 1 Whether the load is too large or the motor stall occurs 2 The type sel...

Page 20: ...ing of PI500 PI500A S keyboard installation opening Opening size of external mounting panel T 1 0 1 5mm 126 5 0 2 Mounting panel Opening panel126 5 82 82 0 2 Dimension drawing of keyboard installation...

Reviews: