Chapter 5 Function parameter
25
Ch
ap
ter
5
setting
1
d0.00
Running frequency
Actual output frequency
0.01Hz
2
d0.01
Set frequency
Actual set frequency
0.01Hz
3
d0.02
DC bus voltage
Detected value for DC bus voltage
V
4
d0.03
output voltage
Actual output voltage
V
5
d0.04
output current
Effective value for Actual motor current
0.01A
6
d0.05
output power
Calculated value for motor output power
0.1kW
7
d0.07
DI input status
DI input status
-
8
d0.08
DO output status
DO output status
-
9
d0.09
AI1 voltage (V)
AI1 input voltage value
0.01V
10
d0.10
AI2 voltage (V)
AI2 input voltage value
0.01V
11
d0.11
AI3 voltage (V)
AI3 input voltage value
0.01V
12
d0.14
Actual operating speed Motor actual running speed
-
13
d0.15
PID setting
Reference value percentage when PID runs
%
14
d0.16
PID feedback
Feedback value percentage when PID runs
%
15
d0.18
High-speed pulse
input frequency
High-speed pulse input frequency display, nit:
0.01Khz
0.01kHz
16
d0.20
Remaining run time
Remaining run time display, it is for timing
run control
0.1Min
17
d0.22 Current power-on time Total time of current inverter power-on
1Min
18
d0.23
Current run time
Total time of current inverter run
1Min
19
d0.24
HDI(DI5) impulse
frequency
HDI(DI5) High-speed impulse input
frequency display, unit: 1Hz
1Hz
20
d0.25
Communication set
value
Frequency, torque or other command values
set by communication port
0.01%
21
d0.27
Master frequency
display
Frequency set by F0.03 master frequency
setting source
0.01Hz
22
d0.29
Command torque (%)
Observe the set command torque under the
torque control mode
0.1%
23
d0.36
Inverter type
G type (constant torque load type)
-
24
d0.37
AI1 voltage before
correction
Input voltage value before AI1 linear
correction
0.01V
25
d0.38
AI2 voltage before
correction
Input voltage value before AI2 linear
correction
0.01V
26
d0.39
AI3 voltage before
correction
Input voltage value before AI3 linear
correction
0.01V
27
d0.41
Motor temperature
inspection function3
PT100 inspect motor temperature value
0
℃
5-1-2.F0 Group -Basic function group
Code
Parameter
name
Setting range
Factory
range
Change
Limit
F0.00
Motor control
manner
Vector control W/O PG
0
2
★
Reserved
1
Summary of Contents for PI500-S 004G1