Solution Tank:

The solution tank is located under the lid, at

the front of the machine, with the filling-funnel 

M1

in an acces-

sible position for easy re-filling.

Note:

Always empty the dirty water collection tank, as described

in the next paragraph, before refilling the tank with the diluted
detergent solution. The solution tank has a maximum capacity
of 20 gallons (73 liters). Always use the products and the dilu-
tion quantities recommended by the seller.  Never use foamy
detergents. Use defoamer if excess foam develops.

Water collection tank:

The dirty water collection tank should

be emptied, preferably each time after use, so that the dirt does
not settle there.  To do this, open the ball valve 

M2,

emptying

dirty water into the proper drain conforming to local regula-
tions. For sludge clean-out, open the port by loosening both
knobs.

Squeegee:

The squeegee has the final task of completing the

drying of the floor and it is very important for it to be in the
correct position.  Lower the squeegee to the working position
by pressing pedal 

M3

.  Adjust the position of the squeegee by

means of the knobs 

M4

so that the black rubber bar is about 

1

32

" (the thickness of a business card)

from the floor. The

squeegee behind this is in para rubber and must press on the
floor with a certain amount of force.  

After the first few

hours the squeegee adjusts itself to the correct angle
and drying becomes even better.

Squeegee pressure is

adjusted by knob 

M14

. An additional squeegee blade may be

added for use on very rough concrete to improve drying and
eliminate squeegee vibration.

Battery installation and charging:

The batteries are sup-

plied separately and must be inserted in the special compart-
ment provided under the lid.  Apply a layer of vaseline to the
terminals and connect in series as shown on page 12. Make
sure that the terminals are correctly tightened.  The battery
charger must be installed in the place set aside for charging the
machine.  The charger is provided with a cable for connection
to the mains, normally 

120v/60HZ.

Check that the voltage cor-

responds to the voltage indicated on the battery charger.
To charge the batteries, connect the connector of the machine
batteries 

M5

to the connector of the battery charger.  The

battery charger will automatically regulate the voltage to the
batteries and will switch itself off when the batteries have been
fully charged.

CAUTION: A)

Make sure key switch is turned “OFF” and bat-

tery connector is unplugged from machine before peforming
any maintenance procedures.  

B)

Battery acid can cause burns.

When working on or around batteries, wear protective clothing and
safety glasses.  Remove metal jewelry.  Do not lay tools or metal
objects on top of batteries.

C)

Charging batteries generate

explosive gases. 

NO SMOKING OR OPEN FLAMES OR SPARKS.  

Make sure

the charger has turned off before disconnecting it from the
batteries.  Charge batteries in a well-ventilated area with the
tanks in the raised and locked position.

120 Volt

60 Hz

To Order Parts Call 1-888-702-5326 - https://monsterfloorequipmentparts.com

Summary of Contents for PAS8

Page 1: ...ERATING THIS EQUIPMENT Predator Automatic Scrubber 28 OPERATORS MANUAL AND PARTS LIST Model PAS28 Contains drawings for all PAS28 models to date PAS202 T o O r d e r P a r t s C a l l 1 8 8 8 7 0 2 5...

Page 2: ...present Do not use or pick up flammable chemicals or liquids with this machine CAUTION Make sure all caution warning and instructional decals are in place and legible Replace damaged or missing label...

Page 3: ...t chemical resistance and styling features 14 Design prevents solution contamination with serviceable access to the solution recovery tanks 15 Curved aluminum squeegee body with reversible rubber sque...

Page 4: ...n additional squeegee blade may be added for use on very rough concrete to improve drying and eliminate squeegee vibration Battery installation and charging The batteries are sup plied separately and...

Page 5: ...arry out the operations of scrubbing and drying at the same time CAUTION Make sure key switch is in the OFF position before installing pad Particularly dirty floors Certain floors or areas may require...

Page 6: ...re available on request together with floor pads recommended for use with the pad driver Black for stripping Green for deep scrub Blue for cleansing and Red for light scrub Water collection tank This...

Page 7: ...expose open flames or sparks in the vicinity of the batteries portable grinders welders etc Do not take current from the batteries using ad hoc clips or other forms of temporary connections Do not re...

Page 8: ...PAS 266 Split pin 24 PAS 264 Support 25 500 193 Pin 26 850 078 Spring 27 430 115 Tie rod 28 700 028 Sulky support 29 850 035 Sulky 30 700 030 Square 31 700 031 Squeegee pedal 32 PAS 265 Cross member 3...

Page 9: ...ter Steel Housing 23 500 212 Split pin 24 PAS 31 Spring 25 PAS 63 Pin Tie Rod 26 PAS 176 Nut 27 PAS 176 Nut 30 700 030 Washer 31 PAS 33 Ring Nut 32 PAS 34 Regulator 33 PAS 280 Support 34 PAS 195 Suppo...

Page 10: ...101 Key machine 70 PAS 65 Screw 71 PS 6A Support with short spring 72 PAS 67 Poly Scrub brush 2 brushes per set 72 PAS 68 Nylo Grit 2 brushes 72 PAS 130 Strata Grit 2 brushes 72 PAS 94 Scrub Grit II...

Page 11: ...PAS 102 Motor seal Pos Part No Description 113 F909 Screen Filter 115 500 068 Float support 116 500 094 Float 117 PAS 103 Seal PAS 17 Complete float 118 PAS 80 Intake hose 119 PAS 191 Hose clamp 120 4...

Page 12: ...tion Valve 148 500 056 Split pin 149 PAS 146 Washer 150 500 051 Lever 151 500 053 Washer 152 500 054 Screw 153 PAS 84 Lid support Hinge 154 700 154 Screw 155 700 155 Screw 156 PAS 110 Hinge Pos Part N...

Page 13: ...118 Washer 191 850 454 Yoke 192 850 496 Handle right support 193 PAS 56 Micro switch 194 850 447 Spacer 195 430 168 Nut 196 430 171 Washer 197 430 173 Screw 198 PAS175 Handle frame 199 PAS 197 Screw...

Page 14: ...PAS 59 Connector 234 430 299 Screw 235 PAS 59 Connector 236 430 297 Washer 237 430 296 Nut Pos Part No Description 238 650 328 Yoke 239 430 072 Screw 240 PAS 54 Vac switch 241 PAS 54 Brush switch 242...

Page 15: ...gauge 244 PAS 53 Master switch Microprocessor Diagnostic Signals The Model PAS28 with serial numbers above 05 97 01616 have an on board diagnostic system as standard equipment The number of light fla...

Page 16: ...W 3 PINK 4 WHITE BLACK 5 WHITE GREEN 6 RED BLACK 1 BLACK 2 WHITE BLUE 3 WHITE YELLOW 4 RED BLACK 7 WHITE GREEN 8 PINK 9 BLUE 10 WHITE RED Model PAS28 with serial number 05 97 01616 and under BRUSH REL...

Page 17: ...INK RED RED GREEN GREEN BLACK WHITE BLACK ORANGE RED GREEN VIOLET KEY START FORWARD SWITCH REVERSE SWITCH SAFETY SWITCH SAFETY SWITCH FUSE 6 3 AMP VACUUM MOTOR BATTERY 30 30 30 30 VAC RELAY BRUSH RELA...

Page 18: ...A Tacony Company 3101 Wichita Court Ft Worth TX 76140 1710 T o O r d e r P a r t s C a l l 1 8 8 8 7 0 2 5 3 2 6 h t t p s m o n s t e r f l o o r e q u i p m e n t p a r t s c o m...

Reviews: