![PowerXtreme XS20s User Manual Download Page 41](http://html1.mh-extra.com/html/powerxtreme/xs20s/xs20s_user-manual_1592312041.webp)
User manual MPPT Solar charge controller PowerXtreme XS20s
E18-XS20s-EN00
www.emergoplus.com
Page 41 of 49
the charging. When the sun goes
down, the opposite takes place.
1 to
14
Light + time control 1
to 14 hours
When sunlight appears, the voltage
of the solar panel will be higher than
where there is no light, and after a
delay the charger will activate the
charging. The load will be turned off
after a pre-set time.
15
Manual mode
In this mode, the user can activate
or deactivate charging by use of the
buttons, regardless whether it is day
or night. This mode was designed
for some specially intended loads,
and is also used during the
debugging process.
16 Troubleshooting mode
Used for the debugging of the
system. The charging is deactivated
with light signals, the charging is
activated without light signals. This
mode makes it possible to quickly
check the proper functioning of the
installation during troubleshooting.
17
Normal on mode
The charger keeps providing voltage
continuously. This mode is suitable
for loads that require current 24
hours per day.
10.4.2 Activating and deactivating of charging manually
Manual operation only works when the charge-mode is set to manual
mode (15). In the main menu press the Set button on activate or
deactivate the charging.