DCM000000054 Rev Q
2-1
Chapter 2
Operation
2 Introduction
This chapter contains information for the standard operation of the LNKA Modules.
2.1 Software Set-Up
The LNKA modules is shipped with the following factory set options:
Table 3 LNKA Factory Set Options
OPTION
RANGE OF VALUES DEFAULT VALUE
Frequency
See Model Chart
Order Specific
Gain
+34 to +84 dB
+34 dB
AGC
+15 to +30 dBm or Disabled
+30 dBm
Module Enabled
On / Off
On
Default values may be changed when an order is placed. Check your order confirmation (shipped
with modules) for customized values.
2.2 Configuration
In line with the versatility of the LinkNet
TM
Platform, it is possible to reconfigure the LNKA module
in the field, either with a Personal Computer (PC) or via the optional Control Module. To use a PC
it is necessary to have a Powerwave CAB000000057 control cable to connect between the
appropriate module's DB15 connector on the back of the card-cage and the standard DB9 RS232
connector on the PC. On the PC a terminal emulation program such as
HyperTerminal
is used to
communicate to the LinkNet Module. The settings are 9600 baud, 8 bits, no parity, and 1 stop bit.
Commands are one or two words followed by pressing
Return
. Commands may be given in upper
or lower-case. Available commands are:
ACCESS USER:
Required as a simple password to gain access to customer settable
parameters and diagnostics. This will time-out after 10 minutes, and may
have to be re-typed.
HELP or ?:
Displays a list of available commands.
LIST:
Displays current settings and status faults, etc.
VER:
Display the current version of software.
ENABLE 1 or 0:
Enables or disables the module.
GAIN ###:
Displays or sets the module gain (in tenths of a dB).
AGCTHRESH ###:
Displays or sets the AGC level (in tenths of a dBm).
AGCEN 1 or 0:
Enables or disables AGC.
Please consult Powerwave Technologies Inc. for further support.