7. Software Installation on your PC 

Connected  by  USB  to  a  PC  or  notebook,  the  Software  enables 

communication  between  the  UPS  and  the  computer.  The  UPS  software 

monitors  the  status  of  the  UPS,  shuts  down  the  system  before  the  UPS  is 

exhausted  and  can  remotely  observe  the  UPS  via  the  Network  (enabling 

users  to  manage  their  system  more  effectively).  Upon  AC  failure  or  UPS 

battery  low,  UPS  takes  all  necessary  actions  without  intervention  from  the 

system  administrator.  In  addition  to  automatic  file  saving  and  system 

shut-down functions, it can also send warning messages via SMS, e-mail etc. 

 

Use  the  bundled  CD  and  follow  the  on-screen  instructions  to  install  the 

software. 

 

Enter the following serial No. to install software: 

511C1-01220-0100-478DF2A 

 

After the software is successfully installed, the communication with UPS 

has been established and a green icon will appear in the system tray.     

 

 

Double-click the icon to use the monitoring software (as above).         

 

You  can  schedule  UPS  shutdown/start-up  and  monitor  UPS  status 

through PC. 

 

Detail instructions please refer to the e-manual in the software.   

 

 

 

 

 

  Check 

www.powerwalker.com/winpower.html

 from time to time to 

get the latest version of monitoring software. 

Summary of Contents for VI 1000T/HID

Page 1: ...Line Interactive UPS PowerWalker VI 500T HID PowerWalker VI 750T HID PowerWalker VI 1000T HID PowerWalker VI 1500T HID Quick Start Guide EN...

Page 2: ...EN...

Page 3: ...Introduction 4 2 Description of Features 4 3 Package Contents 4 4 Product Overview 5 5 Installation and Initial Startup 7 6 Functions Operation 10 7 Software Installation on your PC 11 8 Maintenance 1...

Page 4: ......

Page 5: ...lt in shock hazard as well as violate local electrical codes To reduce risk of overheating the UPS do not cover the UPS cooling vents This unit intended for installation in a controlled environment te...

Page 6: ...device please cut off the power supply quickly and contact the distributor The UPS contains one two large capacity batteries So the shell shall not be opened otherwise such dangers as electric shock...

Page 7: ...th disconnection of this unit from the mains hazardous voltage still may be accessible through supply from battery The battery supply should be therefore disconnected in the plus and minus pole of the...

Page 8: ...longer and more reliability 2 Description of Features Easy to use and install utilized microprocessor control to maximize the reliability and efficiency Equipped with built in boost and buck AVR func...

Page 9: ...Rear Panel VI 500T 750T VI 1000T 1500T AC input RJ11 RJ45 LAN Modem phone line protection USB port IEC outlet AC input RJ11 RJ45 LAN Modem phone line protection USB port IEC outlet Fan ON OFF button S...

Page 10: ...no activity for 3 minutes 1 In low sensitivity mode Lo UPS will tolerate more fluctuations in power and will go on battery power less often If the connected load is sensitive to power disturbances ke...

Page 11: ...ve contaminants Please place the UPS away from other units at least 20 cm to avoid interference Do NOT operate the UPS where the temperature exceeds 0 40 C and the humidity is over 0 90 RH II Connect...

Page 12: ...line for Surge Protection Connect for example a single modem or phone line into surge protected IN outlet on the back panel of the UPS unit Connect from OUT outlet to the computer with another phone l...

Page 13: ...PS unit by pressing the On Off button Turn off the UPS unit by pressing again the On Off button NEVER connect a laser printer or scanner to the UPS unit because in rush current generated by motor s de...

Page 14: ...it will automatically shut down after 5 minutes for energy saving while running on battery mode Disable by default The UPS will restart while AC recovery The green power function can be enable only b...

Page 15: ...saving and system shut down functions it can also send warning messages via SMS e mail etc Use the bundled CD and follow the on screen instructions to install the software Enter the following serial...

Page 16: ...ype Never short circuit batteries When working with batteries remove watches rings and other metal objects and only use insulated tools III Battery module replacement Battery tray removal on tower mod...

Page 17: ...ure safety and high performance use only batteries supplied by BLUEWALKER Take care to firmly press together the two parts of the connector during remounting C Remove the metal protection cover in fro...

Page 18: ...he UPS Verify that the load matches the UPS capability specified in the specs 2 Power cord is loose Reconnect the power cord properly When power failure back up time is shorten 1 Overload of the UPS 1...

Page 19: ...to 40 C non condensing Noise Level Less than 40dB Less than 40dB Line mode Less than 45dB Battery mode Software Monitoring Software WinPower included CAPACITY 500VA 350W 750VA 500W 1000VA 700W 1500VA...

Page 20: ...16 EN 614 01858 00...

Reviews: