background image

 

 

 

 

 

 

 

 

 

 

Inverter SW Series 

User Manual

 

 

 

IMPORTANT SAFETY INFORMATION   

(SAVE THESE INSTRUCTIONS)

 

This manual contains important safety instructions. Please read and follow all instructions carefully 

during installation and operation of the unit. Read this manual thoroughly before attempting to unpack, 

install, or operate the unit 

Insure the wall outlet and inverter are located near the equipment being attached for proper accessibility. 

To reduce risk of damage and injury, please use batteries with good quality. 

Provide adequate ventilation for the battery compartment. The battery enclosure should be designed to 

prevent accumulation and concentration of hydrogen gas at the top of the compartment. 

DO NOT

 expose the unit to rain, snow or liquids of any type. The unit is designed for indoor use only. 

DO NOT

 obstruct the ventilation openings. 

DO NOT 

connect

 neutral of the power distribution box

 on the wall to the 

output neutral of Inverter.

 

Otherwise the reversed polarity will damage the Inverter and the connected equipment. 

 

 

CAUTION!

 Risk of electric shock, do not remove cover. No user serviceable parts inside. 

The battery can energize hazardous live parts inside even when the AC input power is disconnected. 

To avoid electrical shock, turn off the Inverter and unplug it from the AC power source before servicing 

the battery. Servicing the battery can only be performed by trained personnel. 

 

INSTALLING YOUR Inverter SYSTEM   

 

UNPACKING 

 

Inspect the unit upon receipt. The box should contain the following: 

Inverter

1; User Manual

1; Power cord

 

HOW TO DETERMINE THE POWER REQUIREMENTS OF YOUR EQUIPMENT 

 

1.  Insure that the equipment plugged into the AC outlet does not exceed the Inverter unit’s rated 

capacity (refer to TECHNICAL SPECIFICATIONS ). If rated unit capacities are exceeded, an 

overload condition may occur and cause the Inverter unit to shut down or the circuit fuse burn down. 

 

2.  If the power requirements of your equipment are listed in units other than Volt-Amps (VA), convert 

Watts (W) or Amps (A) into VA by doing the calculations below. Note: The below equation only 

calculates the maximum amount of VA that the equipment can use, not what is typically used by the 

equipment at any one time. Users should expect usage requirements to be approximately 60% of 

below value. 

 

HARDWARE INSTALLATION GUIDE 

 

Before installation, please read and understand the following instructions: 

 

1. 

Placement 

The Inverter must be installed in a protected environment away from heat- emitting appliances 

such as a radiator or heat register. Do not install this product where excessive moisture is present. 

 

2. 

Ventilation 

The location should provide adequate air flow around the Inverter with 10 CM minimum clearance 

on all sides for proper ventilation. 

 

3. 

Connect the Battery 

Connect the external battery pack with the DC cables from the back of the Inverter. Follow battery 

polarity guide located near battery cables as below.   

     “+” Red cable for battery positive polarity; 

“-” Black cable for battery negative polarity.   

 

 

 

 

 

 

4. 

Connect to AC and Charge the Battery 

Connect the Inverter to a wall outlet. Avoid using extension cords and adapter plugs. Charging the 

battery for at least 8 hours is recommended to insure that the battery is fully charged. To recharge 

the battery, simply leave the unit plugged into a wall outlet. To maintain optimal battery charge, 

leave the Inverter plugged into an AC outlet at all times. 

This Inverter can be charged even when Inverter is not turned on

.

 

     

5. 

Connect the Load 

Connect the equipment to the Inverter outlet. Please make sure that the total loads of your 

equipments are less than the maximum total power load of the Inverter. 

 

BASIC OPERATION 

 

DESCRIPTION 

 

 

 

 

 

 

 

 

 

1. 

Power Switch 

Press the power switch to turn the Inverter ON or OFF.

 

 

2. 

AC Mode LED 

The green LED will light when utility power is normal. 

 

3. 

Battery Mode LED 

The yellow LED will light when power mains are abnormal and the unit will work in battery mode. 

 

4. 

Fault LED 

The red LED will light when fault or over load occurs. 

 

5. 

AC outlet** 

The unit provides one outlet for connected equipment to insure temporary uninterrupted operation 

during a power failure and against surges and spikes. 

**Note: 2 outlet types available,

 including Schuko and FR, type. 

 

6. 

AC Inlet

   

Connect to utility power through the input power cord. 

 

7. 

Input Voltage Range Selector 

Input voltage range is defined in specification section. Output voltage is the same as input voltage 

in AC mode. 

 

A. Select

  “Narrow” 

setting for general electrical appliance such as TUBE LIGHT, ENERGY 

SAVING LAMP, TV, JUICER & MIXER etc. It is not suitable for high-power motor or inductive 

load, such as the fridge of 1KW, the motor of 800W, AIR COOLER

having risk of rebooting

and so on. In this mode, the Inverter operating voltage in AC mode is within 190~260Vac with 

the same output voltage. The line sensitivity is higher. 

 

B. Select 

“Wide”

  setting to save energy. In this mode the operating range of voltage for the 

Inverter  is 100-290Vac. Therefore the output voltage will be the same as the MAINS input 

voltage. The Inverter  unit in this mode has  a lower sensitivity with a longer transfer time for 

switching from AC mode to battery mode in the event of power failure. You can safely connect 

and use home appliances which are not sensitive to transfer time limitations such as florescent 

tubes, bulbs, TV etc. 

 

8. 

DC Input Cable (Red) 

Connect to battery positive polarity. 

 

9. 

DC Input Cable (Black) 

Connect to battery negative polarity. 

 

  Functional Test

 

 

AC Mode 

The Inverter delivers power to the load derived from the utility and maintains proper battery charge. 

 

On-Battery Mode 

The Inverter operates on battery when the utility voltage has fallen outside the limits. Local users are 

alerted to this mode of operation by visual and audible indicators. The Inverter provides power to the 

load from the battery and the output voltage of the Inverter are regulated within a narrow range 

 

1. 

Switch On 

Press the power switch then the status LED will

 

light up. 

 

2. 

Switch Off 

Press again the power switch, the status LED will go off. 

 

3. 

Cold Start / Start on Battery:   

     This Inverter can be turned on even when AC is not present. 

 

Press the power switch then the status LED will

 

light up. 

ROUTINE MAINTENANCE AND STORAGE

 

 

ROUTINE MAINTENANCE

 

1. 

Use dry soft clothes to clean the panel and plastic parts. Do not use any detergent that contains 

alcoholic ingredient.   

Summary of Contents for 650 SW

Page 1: ...Avoid using extension cords and adapter plugs Charging the battery for at least 8 hours is recommended to insure that the battery is fully charged To recharge the battery simply leave the unit plugged into a wall outlet To maintain optimal battery charge leave the Inverter plugged into an AC outlet at all times This Inverter can be charged even when Inverter is not turned on 5 Connect the Load Con...

Page 2: ...eps every 0 5 seconds TROUBLE SHOOTING Problem Possible Causes Remedy No LED display 1 Battery Weak 1 Re charge battery 2 Battery defective 2 Battery replacement 3 Power switch is not pressed 3 Press and hold power switch Mains normal but not works in AC mode 1 AC Input missing 1 Check AC input connection 2 Input Fuse is blown 2 Unplug the power cord of the Inverter then replace the blown fuse Ala...

Page 3: ...pełną wydajność Bateria będzie ładowana jeśli urządzenie jest podłączone do sieci Rekomendujemy pozostawienie urządzenia podłączonego do sieci permanentnie Inwerter ładuje baterie nawet gdy jest wyłączony 5 Podłącz urządzenie Podłącz urządzenia do wyjścia inwertera Upewnij się że nie spowodują przekroczenia maksymalnego dopuszczalnego obciążenia PODSTAWOWE OPERACJE OPIS 1 Przycisk on off Naciśnij ...

Page 4: ...iśnij przycisk Napięcie wejściowe normalne ale inwerter nie działa 1 Źle podłączona wtyczka 1 Sprawdź wtyczkę Przepalony Bezpiecznik 2 Odłącz urządzenie I wymieć bezpiecznik Ciągły dźwięk alarmu Przeciążenie Odłącz nadmiarowe odbiorniki Zbyt krótki czas podtrzymania na baterii Przeciążenie Odłącz część odbiorników Napięcie baterii jest zbyt niskie Naładuj baterię do pełna W przypadku wyżej nieopis...