7 Simple Fault Diagnosis and Trouble Shooting 

WARNING: There is high voltage inside the machine! Do not open and 

try to repair or maintenance, high voltage may cause shock or death! 

Failure  

Possible reason 

solution 

 
 

    unit 

won’t charge 

A/C in breaker not on 

Make sure that the 

Breaker is fully on 

Fuse Blown 

Change fuse in 10A 

port 

Improper charge 

procedure 

Ensure to turn on 

battery and A/C 

breakers and power on 

unit before plugging in 

 

Won’t Power on 

The mains input cable or 

the battery cable is 

poorly connected 

 

Check and reconnect 

 

Boot alarm 

The battery is low 

Make  sure  that  the 
battery is fully charged 

Load overload 

Removal of noncritical 

loads 

The buzzer buzzes 

for 2 seconds then 1 

second 

The internal temperature 

is too high alarm 

Check the fan and 

cooling holes are 

blocked 

Short Run Time 

Battery not 
charged or 

overloaded 

Make sure battery is 

fully charged and does 

not have too high of 

load 

The "PV" indicator 

does not light when 

there is a sun-lit PV 

module 

 

Solar cable connection 

Please check whether 

the wiring of the Solar 

array is correct and the 

contact is reliable 

When you contact the service staff, please provide the following information: 

Type of unit / date of issue / complete description of the problem (including 

the relevant indicator display status, battery configuration, connection). 

 
 
 
 
 

 

-22- 

8  Technical Data Sheet 

 

Model 

3KW 

Battery rated voltage

vdc

 

51.2 

 
 
 
 

Inverter 

Rated power

w

 

3000 

Input voltage range

vac

 

85-138VAC 

Input frequency

Hz

 

45-65 

Output voltage

vac

 

110 

Output frequency

Hz

 

50/60 

Output wave 

Pure Sine Wave 

Specification of built-in battery 

1*100Ah 

 

 

MPPT 

Solar 

input 

MPPT Voltage Range 

60V~150VDC 

PV Power 

2600W 

Rated charge current 

50A(Max) 

MPPT efficiency 

≥99% 

Floating charge voltage 

56.8VDC 

 
 

DC 

output 

Low voltage recovery voltage 

53.6VDC 

Low voltage protection voltage 

44.8VDC 

5VDC USB output 

2 units / MAX 2A 

12VDC output ports 

2 units /MAX 10A 

Heat dissipation/Cooling 

Temperature control by intelligent 

exhaust fan 

Operating ambient temperature 

-20 - +50

 

Storage ambient temperature 

-25 - +55

 

Operating/Storage ambient 

0-90% No condensation 

External size

W*D*H

mm

 

613*275*511 

Package size

W*D*H

mm

 

730*710*670

 

Note: We reserve the right of modifying this user manual without any notification. 

 
 
 
 
 

-23- 

Summary of Contents for PT-3000

Page 1: ...User Manual PT 3000 Powertronics Inc 370 Mountain St Willimantic CT 06226 844 241 1046 www powertronics us ...

Page 2: ...w voltage protection overload protection short circuit protection over temperature protection Intelligent MPPT solar controller with over charge over discharge protection and current limiting charging protections 2 Installation Storage Instructions 2 1 Out of Package Inspection 2 1 1 Open and inspect the equipment for damage please ensure the Quick Start and user manual are present 2 1 2 If the eq...

Page 3: ...Guide 5VDC Output USB sockets AC Outlets 12VDC Output Guide AC Input Socket AC charger Cooling Fan Solar Input Breaker Battery Input Breaker AC Input Breaker AC Output Breaker External Battery Input Terminals Solar Input Terminals Solar Charger AC Input Terminals AC Output Terminals ...

Page 4: ... 2 3 ...

Page 5: ... Scroll down set key Under the main screen click to view the unit parameters and set the decrements Function keys Press and hold to enter unit mode settings Under settings screen press to confirm the parameters and return to the main screen 4 3 3 3 LED Status Description LED display Description PV Green Light PV start charging OFF PV stop charging LINE Green Light AC is connected and the output is...

Page 6: ...3 3 4 2 Main Menu From the main screen press and hold Function key for 5 seconds to enter the main menu press DOWN or UP to view the sub menu The function of P0 P1 P2 P3 P4 when flashing is as follows Main Menu Functions P4 Buzzer mode P3 Inverter charging current P2 P1 Inverter operating mode P0 Save Exit 7 ...

Page 7: ... UP key and press the Function key to save and exit On Indicates that the buzzer is on 0FF Indicates that the buzzer is off 3 3 5 2 Inverter AC Charging Settings In the main screen press and hold the Function button for 5 seconds to enter the main menu Press the DOWN button to select inverter charging information P3 Press the Function button to enter the setting interface through DOWN or UP keys i...

Page 8: ... When the grid power is back to normal the unit will transfer back to grid power bypassing 03 Battery priority mode Under working mode 03 grid power is not charging the battery The unit can be charged via Solar charger only as Solar and battery are the main power sources Solar charge the batteries and supply the power to the loads through the inverter When the battery is discharged to the low volt...

Page 9: ...ion Battery The external battery s voltage must be consistent with the unit s internal battery voltage 51 2V Make sure the positive and negative terminals are wired correctly Reversing polarity may damage the unit 4 5 Instructions for AC Input The unit has 2 ways for AC input wiring AC Input Socket and AC input terminals Please check below for details 13 WARNING VERY IMPORTANT DO NOT connect AC In...

Page 10: ...AC input terminals is 30A 14 When you want to use the unit as an uninterrupted backup power to your loads you are suggested to wire the AC input with terminals Use the correct size of AC power cable 2 5mm or bigger make sure the AC power voltage is in the range of unit allowance Turn on AC input breaker and battery breaker THEN wire AC power source to the AC input terminals VERY IMPORTANT NOTE DO ...

Page 11: ...ds are connected to the 5VDC Output USB souckets on the front panel The total 5VDC USB output current is 2A The 12VDC loads is connected to the 12VDC Output on the front panel The total 12VDC output current is 2A Make sure the positive and negative of the DC loads are wiring correctly before plug in DC output short circuit may cause the unit damage 17 AC Output MAX 15A AC Output MAX 12VDC LOAD 5VD...

Page 12: ...l relay action the unit AC output is off LCD screen turned off turn off all the breakers 5 4 Battery protection table When the AC output is turned on the relevant protections must beexecuted when the battery voltage reaches the value in the table below Inverter protection voltage parameters Overvoltage protection Overvoltage recovery Low voltage alarm Low voltage protection 71 6VDC 68 2VDC 46 0VDC...

Page 13: ...ies of product requires little maintenance battery only needs to maintain its charge for full life expectancy 6 2 If you do not use the equipment for a long period of time it is recommended it be charged every 4 6 months Under normal circumstances the battery s life will be 3 5 years if found in poor condition you must replace the battery early Replacement of the battery must be carried out by qua...

Page 14: ...ether the wiring of the Solar array is correct and the contact is reliable When you contact the service staff please provide the following information Type of unit date of issue complete description of the problem including the relevant indicator display status battery configuration connection 22 8 Technical Data Sheet Model 3KW Battery rated voltage vdc 51 2 Inverter Rated power w 3000 Input volt...

Reviews: