PowerTech MP3743 User Manual Download Page 3

 

3

I.

 

Matters

 

needing

 

attention

 

1.

 

Keep

 

the

 

product

 

out

 

of

 

reach

 

of

 

children

 

to

 

avoid

 

using

 

it

 

as

 

a

 

toy

 

and

 

causing

 

personal

 

injury.

 

Note!

 

2.

 

Only

 

use

 

the

 

accessories

 

approved

 

by

 

the

 

company

 

or

 

fully

 

comply

 

with

 

the

 

requirements

 

of

 

the

 

company

 

for

 

the

 

specifications

 

of

 

the

 

accessories,

 

or

 

else

 

it

 

may

 

cause

 

danger.

 

3.

 

Operating

 

voltage

 

range

 

of

 

the

 

charger:

 

12/24V

 

battery;

 

it

 

will

 

damage

 

the

 

internal

 

discharge

 

circuit

 

if

 

the

 

voltage

 

exceeds

 

33V,

 

so

 

do

 

not

 

use

 

batteries

 

over

 

36V,

 

or

 

else

 

it

 

may

 

damage

 

the

 

charger.

 

4.

 

The

 

maximum

 

open

 

circuit

 

voltage

 

of

 

PV

 

is

 

100V.

 

Do

 

not

 

exceed

 

the

 

range

 

during

 

use,

 

or

 

else

 

the

 

charger

 

may

 

be

 

damaged.

 

5.

 

Do

 

not

 

touch

 

the

 

heat

 

sink

 

in

 

the

 

process

 

of

 

product

 

operation

 

to

 

avoid

 

hot

 

hands.

 

It

 

is

 

recommended

 

to

 

use

 

the

 

product

 

on

 

the

 

wall.

 

6.

 

Operating

 

temperature:

 ‐

10~+40°C.

 

7.

 

It

 

is

 

strictly

 

forbidden

 

to

 

use

 

in

 

an

 

environment

 

that

 

may

 

be

 

exposed

 

to

 

rain,

 

which

 

may

 

cause

 

danger.

 

 

Summary of Contents for MP3743

Page 1: ...1 12V 24V 30A MPPT Solar Charge Controller for Lithium or SLA Batteries MP3743 User Manual ...

Page 2: ...t picture 4 5 III Description of basic functions 5 6 III Description of LCD screen 7 8 IV Operation of machine buttons and function introduction 8 9 V Wire diameter requirements 9 VI Electrical parameters 10 VII Troubleshooting 11 VIII Specifications 11 ...

Page 3: ...rger 12 24V battery it will damage the internal discharge circuit if the voltage exceeds 33V so do not use batteries over 36V or else it may damage the charger 4 The maximum open circuit voltage of PV is 100V Do not exceed the range during use or else the charger may be damaged 5 Do not touch the heat sink in the process of product operation to avoid hot hands It is recommended to use the product ...

Page 4: ...ter OK button 5 Green LED light off when no charging flashing during charging stay on when fully charged 6 Red LED light off when no error error alarm when the light is long on lithium battery only has 12V gear other gear flashing red light error 7 2 5V 3A USB output 8 LCD screen Remark The operations of panel items 1 4 are explained below 8 6 7 5 4 3 2 1 ...

Page 5: ...l input a The maximum open circuit voltage of PV is 100V b PV integrates anti reverse reverse connection alarm E8 no charging please eliminate the fault c 12V battery PV input voltage range is 16 80V d 24V battery PV input voltage range is 32 80V 2 Battery output function a Identify 12 24Vbattery automatically the maximum charging current is 30A b Anti reverse connection E1 alarm 3 Load output fun...

Page 6: ...t external analog resistance 100K 10 C 3 12V battery charging temperature 20 C 5 C 13 5 0 3 VDC test external analog resistance 39K 30 C 4 24V battery floating charge temperature 0 C 40 C 28 2 0 3 VDC test external analog resistance 430K 20 C 5 24V battery floating charge temperature 0 C 20 C 5 C 27 6 0 3 VDC test external analog resistance 100K 10 C 6 24V battery floating charge temperature 20 C 5 C...

Page 7: ...ntering the setting parameters and turn off when exit D WIFI icon WIFI ON OFF optional default ON F Battery level icon display the corresponding icon according to the battery voltage I Load icon turn on when the load is turned on synchronized with the load switch ON J Connector three up corresponding to PV middle corresponding to battery down corresponding to load K Currently identified battery ty...

Page 8: ...n Switch among ery voltage load voltage PV voltage and me interface in turn b Press and hold MENU to enter the parameter interface Then press to switch among the 8 interfaces in turn 1 type selec on S STD default level L LI A AGM 2 WIFI switch ON OFF default ON 3 Load undervoltage range of 12V b ies 10 11 5V default 10V s range of 24V b ies 20 23V default 20V 4 Load undervoltage recovery range of ...

Page 9: ...d on the screen 2 UP button description Enter the parameter setting interface press UP time plus 1 voltage plus 0 1V press and hold time load voltage values can be accumulated Press in default interface after power on switch among battery voltage current load voltage current and PV voltage current 3 Down button description Enter the parameter setting interface and press DOWN time minus 1 voltage m...

Page 10: ...3 4A Max Standby current Battery input 12V Separate MPPT charger 60 mA MPPT charger WIFI module 160 mA Protective function PV battery input high low voltage protection Yes PV battery reverse connection protection Yes Load overcurrent short circuit protection Yes Temperature protection Yes 90 C Mechanical dimensions Length X width X height mm 238 177 63 Weight 1 5 KG General data Operating temperat...

Page 11: ...00V E7 Over temperature protec stop charging when heat sink temperature 90 C resume when temperature 60 C E8 PV reverse conne on please correct ery over and under voltage range Capacity 12V 24V low voltage pr LCD display E2 8 18V Capacity 12V 24V Over voltage protec on LCD display E5 15 31V Remark Please eliminate the fault according to the error code If the machine s does not respond the error is...

Reviews: