background image

 

 
 

Standard Timer1

 

&

 

Timer2

 

setup, with NLF=OFF 

If you set NLF=OFF, then you can program the standard load control 
functionality with Timer1 and Timer2. Press

 

“menu”

 

button

 

6

 

times 

from the default window, taking you

 

to NLF setup

 

interface. Press 

“enter” button once, choose NFL OFF via ‘Pageup/Pagedown’

 

button, 

and then confirm by “enter”. 
 
 

Press

 

“menu”

 

button once from NLF window, Window

 

will

 

switch

 

to

 

Timer1 setup

 

interface.

 

Press

 

“enter”

 

button

 

once, you

 

can

 

adjust

 

‘Hour’

 

via

 

‘Pageup/Pagedown’

 

button. After

 

‘Hour’

 

setup

 

press

 

‘enter’

 

button

 

for

 

confirmation

 

and

 

switch

 

to

 

‘Minute’

 

adjustment. You

 

can

 

use

 

‘Pageup/Pagedown’

 

button to

 

adjust

 

it. This

 

can

 

be

 

confirmed

 

by

 

pressing

 

‘enter’

 

button. Through

 

‘Pageup/Pagedown’

 

button,

 

choose

 

‘ON’

 

or

 

‘OFF’ or ‘ON/OFF’ and then

 

confirm

 

by

 

‘enter’

 

button. 

 

Press

 

‘menu’

 

button again,

 

window

 

will

 

switch

 

to

 

Timer2

 

setup

 

interface.

 

Similar

 

operation

 

for

 

time

 

and

 

ON/OFF

 

setup

 

as

 

mentioned above. 

 

NOTE for programming Timer1 & Timer2

 

Setting either Timer to ON

 

sets the

 

time

 

when

 

you

 

want

 

to

 

turn the

 

load

 

on.

   

Setting either Timer to OFF

 

sets the

 

time

 

when

 

you

 

want

 

to

 

turn the

 

load

 

off.

   

Setting either Timer to “ON/OFF” will disable the timer, and the

 

load

 

output will revert to manual load 

control.

 

 

 

 

 

 

Functional Explanations

 

 
 

1.

  

PWM

 

Charge

 

control 

Depending

 

on

 

the

 

actual

 

battery

 

level,

 

various

 

charging

 

procedures,

 

float

 

charging,

 

boost

 

charging

 

and

 

equalization

 

charging

 

are

 

automatically

 

performed.  The

 

final

 

charging

 

voltage

 

is

 

temperature

 

compensated. 

 
2.

  

Deep

 

discharging

 

protection 

If

 

the

 

battery

 

falls

 

below

 

a

 

specified

 

charge

 

level

 

or

 

battery

 

voltage,

 

the

 

load

 

output

 

is

 

disconnected

 

and

 

the

 

discharge

 

of

 

the

 

battery

 

is

 

prevented.

 

The

 

set

 

points

 

of

 

the

 

deep

 

discharging

 

protection

 

are

 

predefined

 

and

 

cannot

 

be

 

reset. 

 

3.

  

MPPT

 

function 

MP-3735 uses the

 

latest

 

MPPT

 

technology

 

at

 

all

 

times

 

which gives

 

the maximum

 

available

 

output

 

of

 

the

 

solar

 

module. 

 

4.

  

5V

 

USB

 

output 

Provide

 

5Vdc/500mA

 

power

 

supplier. 

 

5. 

 

2

 

timers,

 

control the load output

 

automatically. 

Summary of Contents for MP-3735

Page 1: ...1 Operating Manual MP 3735 ...

Page 2: ...V or 24V nominal voltage solar PV array 4 Do not connect any defective or damaged measuring equipment 5 Follow general safety and accident prevention regulation 6 Never alter or remove the factory plates and identification labels 7 Keep children away from PV systems 8 Never open the device 9 Only one solar array can connect with one controller only 10 Never touch bare cables ends Other risks Dange...

Page 3: ...Compensation Manual load switch with automatic re start Two timer schedule programmable MPPT technology capturing more energy from sun What is MPP tracking MPPT MPPT stands for Maximum Power Point Tracking This describes a process by means of which the solar module is always operated at the point of maximum possible power The point of maximum power can vary depending on the operating mode local co...

Page 4: ...ming Default window The default window will show battery voltage capacity volume of the battery and an overview of the system operation Manual load control At the default display window press the enter button to control the load ON or OFF The load icon will turn display to indicate if the load is turned on or off Charge current Press menu button once to check charging current one press from defaul...

Page 5: ...nce it s done press enter button for final confirmation Bulk charge voltage Press menu button 4 times from the default window Window will switch to BULK voltage programmable setup interface Press enter button once you can program charge voltage via the Pageup Pagedown button 12V Battery 13 8V 14 8V 24V Battery 27 6V 29 6V Float charge voltage Press menu button 5 times from the default window Windo...

Page 6: ...n button and then confirm by enter Timer 2 NLF OFF Press menu button again from Time1 window will switch to Timer2 setup interface Press enter button once you can adjust the Hour 1 12hours via Pageup Pagedown button and then confirm by enter NOTE Timer1 hour setting controls the time the load is turned ON after entering night mode Timer2 hour setting controls the time the load is turned OFF after ...

Page 7: ...tup as mentioned above NOTE for programming Timer1 Timer2 Setting either Timer to ON sets the time when you want to turn the load on Setting either Timer to OFF sets the time when you want to turn the load off Setting either Timer to ON OFF will disable the timer and the load output will revert to manual load control Functional Explanations 1 PWM Charge control Depending on the actual battery leve...

Page 8: ...erature Installation Danger of explosion from sparking Danger of electric shock Only install the controller near the battery on a suitable surface This surface should be solid stabile even dry and nonflammable The battery cable should be as short as possible 1 2m and have a suitable cable diameter size for minimum loss Recommended cable for MP 3735 is 25 sq mm and 2 m length Do not install MP 3735...

Page 9: ...charge controller 2 1 Mark the position of controller fix holes on the walls 2 2 Drill 4pcs Ø6mm holes and insert dowels 2 3 Fix the controller to the wall with the cable openings facing downwards using 4 oval head screws M4x35 DIN 7996 Grounding Grounding MP 3735 is not technically required when installing a stand alone solar system However if required common grounding of the negative of the PV a...

Page 10: ...ttery is allowed to absorb current at a constant voltage The constant voltage regulation prevents overheating and battery gassing this stage terminates when the battery current is below 3 Amp or after 3 hours entered in absorption mode Float Maintenance After the battery is fully charged the controller reduces the battery voltage to a float charge providing minimal current Protection functions Ove...

Page 11: ...t the second error code is displayed after remedying the more significant error The following meaning is assigned to the different error codes 1 Meaning Battery polarities reverse warning Remedy Reconnect cable of battery in proper way 2 Meaning Battery is wrong Remedy Check battery voltage it might be too low or too high Recharge battery manually if necessary If battery can t be recharged it migh...

Page 12: ... it gets higher voltage when charging due to the depreciation of the capacity Replace the battery system to see if the problem still exists Electrical products should not be disposed with household waste Please recycle where available Check with your local authority or retailer for recycling advice Specifications are subject to change without prior notice ...