Version 1.3-130603
14
low-input voltage warnings and shutdowns. This is due to the DC voltage
drop in the cables from the battery to the inverter.
The longer and narrower the cables, the greater the voltage drops.
WARNING!
DC wiring terminations.
Ensure all the DC connections and terminations are
secure and tight. Loose connection can cause
overheating and fire.
The following table recommends the cable size for optimum inverter
performance.
SU Series
Wire AWG Inline Fuse
Description
MI5703
#12
25A
Black 1M + Red 1M
MI5702
#10
25A*2
MI5704
#6
30A*4
MI5712
#4
25A*6
MI5706
30A*6
MI5708
#2
30A*8
MI5710
#1
25A*12
Lay the flexible earth cable from the earthing point of the vehicle to the
earthing point of the inverter.
If cables are to be fed through metal walls or walls with sharp edges, use
glands or proper bushings to prevent cable damage.
Do not lay cables that are loose or bent next to electrically conductive
materials.
Summary of Contents for MI5700
Page 1: ...Version 1 3 130603 0 Pure Sine Wave DC TO AC Power Inverter User s Manual ...
Page 10: ...9 5 3 Rear Panel Operations SONDAR R SONDAR R SONDAR R SONDAR R ...
Page 16: ...15 6 Mechanical Drawings SONDAR R SONDAR R I N V PO W ER O VER LO AD O VER TEM P ...
Page 17: ...Version 1 3 130603 16 SONDAR R ...
Page 18: ...17 SONDAR R ...
Page 19: ...Version 1 3 130603 18 ...