![PowerTech MB3910 Instruction Manual Download Page 11](http://html.mh-extra.com/html/powertech/mb3910/mb3910_instruction-manual_1591604011.webp)
8
PRODUCT FEATURES:
OPERATION:
Step 9: Analyse
Tests if the battery can hold charge. Batteries that cannot hold charge may
need to be replaced.
Step 10: Maintenance
Continuously monitors the battery voltage to determine if a maintenance
charge should be initiated. If the terminal voltage falls below 12.8V (12V)
and 25.6V (24V), the charger will start the Maintenance cycle until voltage
reaches 13.6V (12V) and 27.2V (24V) and then discontinues the charge cycle.
The cycle between Trickle and Maintenance is repeated indefinitely to keep
the battery at full charge, without overcharging. The battery charger can be
left connected indefinitely.
WARNING!
Before you carry out any work on the battery charger
always pull the mains plug out of the mains socket.
WARNING!
DANGER OF ELECTRIC SHOCK! DANGER OF DAMAGE
TO PROPERTY! DANGER OF INJURY!
Ensure that you do not strike electrical cables, gas or water
pipes when you are drilling into the wall. If necessary, check
the wall using a suitable detector before you drill.