15
INSTRUCTIONS PL600/PL1000
5). Breach the three holes at the bottom and mark the points by the holes as reference.
6). Drill the holes in the wall and fix the bottom to the wall by three screws. See
Figure 3.3.4 (5)
.
7). Connect the electric wires to the terminals as shown in
Figure 3.3.4(6)
, and it
’s not required to distinguish any
polarity. The terminals can be removed for connecting the wires easily.
8). Turn the key and insert the shell on the bottom. Turn the key back to the center position and the shell will be fixed
to the bottom.
9). Tighten the lock body with the two screws and insert the round cover by pressing it to attach to the whole unit.
Figure 3.3.4 (5)
Figure 3.3.4 (6)
3.3.5 PPB-1 Push Button
1). PPB-1 push button is installed indoors at the height of about 100cm, so that it could be used by most people.
2). Remove the round cover (A) by prizing it out with a screwdriver. See
Figure 3.3.5 (1)
.
3). Unscrew the two screws beside the button.
4). Separate the upper shell with the bottom. See
Figure 3.3.5 (2)
.
5). Breach the three holes at the bottom and mark the points by the holes as reference.
6). Drill the holes in the wall and fix the bottom to the wall by three screws. See
Figure 3.3.5 (3)
.
Figure 3.3.5 (1)
Figure 3.3.5 (2)
A
Figure 3.3.5 (3)
3.4 Power Supply Connections
Please kindly notice that the operation of power connection should be carried out by a qualified electrician with
following steps:
1). Make sure the gearmotor is not connected to the power supply before the installation is done.
2). Make sure all the wires are firmly connected.
3). Supply the gearmotor with the power.