SPECIFIC SAFETY RULES FOR AIR FILTRATION SYSTEM

2

Be aware of general power tool safety. Make sure all the 
safety rules are understood.
•  Disconnect the machine from power source whenever 

adjusting or replacing any parts.

•  Do not plug air filtration system in unless switch is in the 

“OFF” position.

•  Keep hands away from all moving parts.
•  Wear eye protection or face shield during operation.
•  Make sure all mobile parts move freely and are free 

from interference.

•  If ceiling mounted, bottom of air filtration system must 

be at least 7 feet above the floor.

•  If ceiling mounted, mounts must be anchored to building 

structure which will support a minimum of at least 
100 pounds. Never mount to surfaces such as dry wall 
or false ceiling grinds, etc.

ASSEMBLY

UNPACKING

Refer to Figure 1

The air filtration system is shipped assembled and 
requires minimum assembly and installation.
•  Examine shipping carton for freight damage before 

opening. If shipping carton is damaged file a claim with 
the carrier immediately.

•  Carefully remove all contents from shipping carton. The 

shipping carton contains:

  1 -  Air Filtration System (with 5-Micron pleated-type 

outer filter and 1-Micron bag-type inner filter)

  1 - Remote Control (with two AA batteries)
  4 - Mounting Brackets
  8 -  3 in 1 M6 Bolts (include bolt, flat washer and lock 

washer) (mounting bracket assembly)

  4 - M6 Eye Bolts
  4 - Flange Nuts (eye bolt assembly)
  4 - Rubber Feet
  4 - Double Sided Tape (Rubber Feet Assembly)
  1 - Owner's Manual (not shown)

NOTE:

 Contact the customer service center if any of these 

parts are missing. 

NOTE: 

After unit is assembled dispose of all packaging 

material in an environmentally safe way.

Air Filtration 

System

Remote Control

3 in 1 M6 Bolts (8)

Eye Bolt (4)

Mounting Brackets (4)

Figure 1

2

ASSEMBLY

SPECIFIC SAFETY RULES

2

2

•  To reduce the risk of electrical shock, do not expose air 

filtration to water or rain. 

•  Never duct a machine directly into the air 

filtration system.

•  Do not use air filtration system without filters in place.
•  To avoid a potentially dangerous situation, do 

not use this machine to filter flammable vapors or 
smoke. This air filtration system is designed and 
intended for the filtration of air borne wood dust only. 
It is neither designed nor intended for any other 
purpose whatsoever.

•  Use the machine for filtering wood dust only. Not for 

use filtering sheet rock dust, silica, lead paint dust, 
asbestos, bio-hazards, smoke, toxic fumes, spray paint 
or flammable liquids.

•  Failure to follow these rules may result in serious 

personal injury/or property damage. 

Rubber Feet (4)

Double Stick Tape (4)

     CAUTION

The air filtration system is too heavy to be lifted by one 
person. Obtain assistance from others before trying to lift 
or move.

Flange Nuts (4)

Summary of Contents for AF1045

Page 1: ...r safety instructions operating procedures and warranty Put it and the original sales invoice in a safe dry place for future reference 20 0805 Visit us on the web at powertecproducts com QUESTION 1 84...

Page 2: ...Speed 63 dB MOTOR SPECIFICATIONS This air filtration system is supplied with a 1 5 HP motor installed The 120 Volt AC universal motor has the following specifications Motor Amperage 3A Voltage 120 Her...

Page 3: ...your workshop childproof with padlocks master switches or remove switch keys to prevent any unintentional use of power tools 1 SAFETY RULES TOOL MAINTENANCE Turn the machine OFF and disconnect the ma...

Page 4: ...n 1 M6 Bolts include bolt flat washer and lock washer mounting bracket assembly 4 M6 Eye Bolts 4 Flange Nuts eye bolt assembly 4 Rubber Feet 4 Double Sided Tape Rubber Feet Assembly 1 Owner s Manual n...

Page 5: ...up on the clips located at the top and bottom of the cabinet and remove the outer filter Pull the inner filter from the cabinet Remove the four Phillips head screws securing the inner grate and remove...

Page 6: ...o right and 24 1 2 from front to rear With assistance raise and secure the air filtration system eye bolts to the four hanging lines Figure 7 Anchor not supplied Chain Cable or Steel Strapping Lines n...

Page 7: ...t fingers to touch the terminals of plug when installing or removing from outlet Inspect tool cords periodically and if damaged have it repaired by an authorized service facility The conductor with in...

Page 8: ...e HI LED light will illuminate to indicate the selected speed FILTRATION TIMING NOTE The filtration timing can ONLY be controlled with the remote The TIMER button controls the timer setting The 1 HR 2...

Page 9: ...filter The arrow on the outer filter indicates the air flow direction ensure the filter is positioned properly Figure 13 Clip Inner Outer Arrow REMOTE CONTROL BATTERY REPLACEMENT Remove the battery co...

Page 10: ...ck circuit for proper voltage 2 Motor capacitor has failed 2 Replace motor capacitor 3 Control panel circuit board has failed 3 Inspect or replace control panel circuit board System has vibration or i...

Page 11: ...NOTE 9 NOTES...

Page 12: ...AIR FILTRATION SYSTEM PARTS ILLUSTRATION 10 PARTS LIST 10...

Page 13: ...g Washer 6 mm 14 24 1045 024 Flat Washer 6 mm 10 25 1045 025 Housing 1 26 1045 026 Mounting Bracket 4 27 1045 027 Hex Head Bolt M6X12 8 Key Part Description Qty 28 1045 028 Handle 2 29 1045 029 Flange...

Page 14: ...rranty service you must present the proof of purchase documentation which includes a date of purchase POWERTEC will either repair or replace any defective part at our option at no charge to you The re...

Page 15: ...NOTE...

Page 16: ...Southern Technologies LLC Waukegan IL 60087...

Reviews: