16
TEMPERATURE CONTROL /OVERLOAD PROTECTION
When the temperature of battery is too high and the machine switches off automatically.
•
Switch the power tool off.
•
Allow the battery to cool down before continuing to work.
When the power tool is blocked and switches off automatically.
•
Remove the power tool from the workpiece.
•
As soon as the blockage is corrected, the power tool will continue to work at the set stroke rate.
IMPORTANT CHARGING NOTES
WARNING:
Battery packs are shipped in a low charge condition to prevent possible
problems. Therefore, you should charge them before first use.
•
Use only POWERSMART battery charger (Model#PS76018C)
•
Charge time is approximately 2.5hours, and is dependent upon the type of battery pack.
•
Make sure the power supply is normal household voltage, 120V, AC only, 60Hz.
•
Attach the battery pack to the charger by aligning the raised ribs on the battery pack with the grooves
in the charger, then slide the battery pack onto the charger.
•
Press down on the battery pack to be sure contacts on the battery pack engage properly with contacts
in the charger. Latches should snap into ensure charger is correctly connected.
•
Do not place the charger in an area of extreme heat or cold. It will work best at normal room
temperature.
•
The battery pack may become slightly warm to the touch while charging. This is normal and does not
indicate a problem.
•
The red LEDs will remain on while charging.
•
When the green LEDs is light, this indicates the battery is fully charged.
•
To remove the battery pack from the charger, depress latches and pull up on the battery pack.
•
When the battery pack is fully charged, remove it from the charger.
MAINTENANCE
WARNING:
In order to avoid personal injury and the risk of fire and electric shock,
remove the battery pack before adjusting, inspecting, or cleaning the power tool.
WARNING:
When servicing, use only identical replacement parts. Use of any other parts
could create a hazard or cause product damage.
Be alert for battery packs that are nearing their end of life. If you notice decreased tool performance
or significantly shorter running time between charges then it is time to replace the battery pack.
Failure to do so can cause the tool to operate improperly or damage the charger.
Clean the saw blade holder preferably with compressed air or a soft brush. Remove the saw blade
from the power tool for this. Ensure proper operation of the saw blade holder by applying a suitable
lubricant.
Ventilation openings and switch levers must be kept clean and free of foreign matter. Do not attempt
to clean by inserting pointed objects through opening.
Avoid using solvents when cleaning plastic parts. Most plastics are susceptible to damage from
various types of commercial solvents and may be damaged by their use. Use clean clothes to remove
dirt, oil, grease, etc.
Summary of Contents for 97615L
Page 2: ...2...