9.2 

Cleaning of air vents 

The machine should be kept clean so as to let cooling air pass freely through the machine 
vents. 

9.3 

Greasing of couplings 

To ensure an easy connection and that o-rings do not dry up; the couplings should be greased 
regularly. 

10 STORAGE 

The machine should be stored in a frost-free room! 
Pump, hose and accessories should always be emptied of water prior to storing as follows: 
1. 

Stop the machine (turn 

the start/stop switch “O” and detach water hose and nozzle. 

2. 

Restart the machine and activate the trigger of the trigger gun. Let the machine run until 
no more water runs through the trigger gun 

3. 

Stop the machine, unplug and wind up hose and cable. 

4. 

Place trigger gun, lance, nozzles  and other accessories in the holders of the machine. 
The hook can be used for storage of the hose and cord 

Should the machine by mistake be frozen, it will be necessary to check it for damage. 

WARNING: Never start up a frozen machine. Frost damages are not covered 
by the guarantee! 

11 TROUBLE SHOOTING 

SYMPTOM 

CAUSE 

RECOMMENDED ACTION 

Machine refuses to 
start 

Machine not plugged in  

Plug in machine. 

Defective socket  

Try another socket. 

Defective extension cable  

Try without the extension cable. 

Fluctuating pressure 

Pump is sucking air 

Check that hoses and connections 
are airtight. 

Valves dirty, worn out or stuck 

Contact your nearest service centre 

Water supply not sufficient 

Increase water pressure, check for 
blockage of garden hose and/or 
change to bigger hose. 

Pump seals worn 

Contact your nearest service centre 

Machine stops 

Incorrect mains voltage 

Check that the mains voltage 
corresponds to specification on the 
name plate 

Thermal sensor activated  

Leave the machine for 5 minutes to 
cool down 

Nozzle partially blocked  

Clean the nozzle with a needle and 
by spraying water backwards 
through the nozzle 

Amperage increase 

Try without the extension cable. 

Machine pulsating 

Air in inlet hose/pump  

Allow machine to run with open 
trigger until regular working pressure 
resumes. 

Inadequate supply of mains 
water  

Increase water pressure, check for 
blockage of garden hose and/or 
change to bigger hose. 

Summary of Contents for POWXG90400

Page 1: ...y of storage hook and gun holder 4 5 2 Assembly of the gun Fig 1 4 6 OPERATION 4 6 1 Connection of garden hose Fig 2 4 6 2 Mounting of high pressure hose Fig 3 5 6 3 Mounting of lance and nozzle 5 6 4...

Page 2: ...s Keep the packaging materials as far as possible till the end of the warranty period Dispose it into your local waste disposal system afterwards WARNING Packing materials are no toys Children must no...

Page 3: ...or wet unplug it immediately Do not put it in water Tires and tire valves may be damaged by the high pressure jet and then burst Never use the machine in an environment where there could be a danger o...

Page 4: ...d A thermal sensor protects the motor against overloading The machine will restart after a few minutes when the thermal sensor has cooled 5 ASSEMBLY This section will explain in details how to make yo...

Page 5: ...ature 50 C 3 Turn on the water 6 5 Start stop of the machine The trigger gun and lance is affected by a thrust during operation therefore always hold it firmly with both hands IMPORTANT Point the nozz...

Page 6: ...zna d wi ku mo e przekracza 85 dB A w takim wypadku nale y zastosowa rodki indywidualnej ochrony s uchu aw vibration level 2 1 m s K 1 5 m s 9 MAINTENANCE AND CLEANING WARNING Always disconnect the el...

Page 7: ...frozen machine Frost damages are not covered by the guarantee 11 TROUBLE SHOOTING SYMPTOM CAUSE RECOMMENDED ACTION Machine refuses to start Machine not plugged in Plug in machine Defective socket Try...

Page 8: ...blocked Clean the filter Hose kinked Straighten out hose Machine often starts and stops by itself Pump and or trigger gun is leaking Contact your nearest service centre No water supply Connect inlet w...