9.3
Operation
with
double
cable (Fig 5)
Loosen the nuts
of
the
3 screws
located
on
the load hook with pulley (13)
and
remove the
cover plate located on the
side.
Place the
steel cable (7)
around the deviating
shaft and
reattach the
cover
plate
and
nuts. Please be
sure
that the load hook with pulley
(13)
is
installed properly
and
that the nuts
are securely
tightened.
Please insert the load hook (12)
attached
to the
cable
into the hook bracket (5)
of
the
mounting
casing (3).
10 CLEANING AND MAINTENANCE
Disconnect the power plug prior to performing any work on the device.
Clean the device using a damp cloth and some liquid soap. Never use cleaning agents or
solvents, these could damage the device's plastic parts.
Regularly inspect the total length of the steel cable (7) for damages as well as the
functionality of the limit bracket (Wind cable hoist until the stopper (10) activates the limit
bracket of the micro switch).
If the steel cable (7) is damaged (split or bent, fig 6), a professional must replace it using
original replacement parts.
During assembly of the cable, it is imperative to remember the stopper in order to ensure a
secure limit stop.
Inspect the free movement of all mechanical components after the power plug has been
disconnected.
Replace lost parts only with original parts.
Return the device to your seller to ensure professional recycling.
11 TECHNICAL DATA
Rated voltage
230v~
Rated frequency
50 Hz
Power rating:
500W
Rated current
2.18 A
Max. loading capacity
-for single cable
-for double cable
100 kg
200 kg
Cable speed
-for single cable
-For double cable
8m/min
4m/min
Hoisting height
-for single cable
-For double cable
12 m
6 m
Cable diameter
3,0 mm
Protection rating
IP54
Motor category
M1
Work duty
S3:20%-10min
Protection rating
I
Weight
10.5 kg