7  USE OF THE COMPRESSOR 

7.1 

Voltage 

The  compressor  is  equipped  with  a  mains  cable  with  shock-proof  plug.  Before  you  use  the 
machine, make sure that the mains voltage complies with the specifications on the rating plate. 
Long supply cables, extensions, cable reels etc. cause a drop in voltage and can impede motor 
start-up. In the case of low temperatures below +5°C, motor start-up is jeopardized as a result 
of stiffness. 

7.2 

Switching ON/OFF 

To switch on the equipment set the On/Off push the switch (ref. 1). Push the On/Off switch (ref. 
1) again to switch off the equipment. 

7.3 

Adjusting the pressure 

 

You can adjust the pressure on the pressure gauge (ref. 6) using the pressure regulator 
(ref. 3). 

 

The set pressure can be taken from the quick lock coupling (ref.4). 

As soon as the tank pressure is built up, the motor switches off 
automatically. 

The motor switches automatically on as soon as the tank pressure 
becomes too low. 

7.4 

Safety valve 

The safety valve has been set for the highest permitted pressure of the pressure vessel. It is 
prohibited to adjust the safety valve or remove its seal 
Actuate the safety valve from time to time to ensure that it works when required. Therefore you 
need to remove the protection cover. 

7.5 

Fitting the air filter 

Remove the transportation stop with a screwdriver or similar and screw the air filter (Ref. I) 
securely to the equipment (Fig. 1a-1b). If supplied, insert the  suction tube inside the filter 
cover (Fig. 1c). 

8  CLEANING AND MAINTENANCE 

8.1 

Maintenance 

Never clean the machine and its components with solvents, flammable or toxic liquids. Us only 
a damp cloth making sure you have unplugged the compressor from the current outlet. 
After approx. 2 hours of use, the condensate that has formed must be drained from the receiver. 
First of all, vent all the air using the accessory connected, as described above. Back off vent 
valve 5 located underneath the compressor (switched off beforehand) by two turns, taking care 
to maintain the compressor in a vertical position. After draining all the water, draw up the valve 
tightly. 

Warning: if the water that condenses is not drained, it may corrode the 
receiver, reducing its capacity and impairing safety. 

As it is a contaminating product, condensate must be DISPOSED of in 
accordance with laws on protection of the environment and current 
legislation 

Summary of Contents for POWX1724S

Page 1: ...fety 3 5 3 Personal safety 3 5 4 Power tool use and care 4 5 5 Service 4 6 SPECIFIC SAFETY WARNINGS 4 6 1 Do s 4 6 2 Don ts 5 7 USE OF THE COMPRESSOR 6 7 1 Voltage 6 7 2 Switching ON OFF 6 7 3 Adjusting the pressure 6 7 4 Safety valve 6 7 5 Fitting the air filter 6 8 CLEANING AND MAINTENANCE 6 8 1 Maintenance 6 9 TECHNICAL DATA 7 10 NOISE 7 11 WARRANTY 7 12 ENVIRONMENT 8 13 DECLARATION OF CONFORMI...

Page 2: ... PACKAGE CONTENT LIST Remove all packing materials Remove remaining packaging and transit supports if existing Check the completeness of the packing content Check the appliance the power cord the power plug and all accessories for transportation damages Keep the packaging materials as far as possible till the end of the warranty period Dispose it into your local waste disposal system afterwards WA...

Page 3: ...g a power tool will increase the risk of electric shock Do not abuse the cord Never use the cord for carrying pulling or unplugging the power tool Keep cord away from heat oil sharp edges or moving parts Damaged or entangled cords increase the risk of electric shock When operating a power tool outdoors use an extension cord suitable for outdoor use Use of a cord suitable for outdoor use reduces th...

Page 4: ... tool s operation If damaged have the power tool repaired before use Many accidents are caused by poorly maintained power tools Keep cutting tools sharp and clean Properly maintained cutting tools with sharp cutting edges are less likely to stick and are easier to control Use the power tool accessories and tool bits etc in accordance with these instructions and in the manner intended for the parti...

Page 5: ... 15 means 1 5 minutes On 8 5 minutes OFF In case of overheating the thermal cutout of the motor is released automatically cutting off the power when the temperature is too high due to excess current take off The motor restarts automatically when normal temperature conditions are restored 6 2 Don ts Never direct the jet of air towards persons animals or your body Never let the compressor come into ...

Page 6: ...ohibited to adjust the safety valve or remove its seal Actuate the safety valve from time to time to ensure that it works when required Therefore you need to remove the protection cover 7 5 Fitting the air filter Remove the transportation stop with a screwdriver or similar and screw the air filter Ref I securely to the equipment Fig 1a 1b If supplied insert the suction tube inside the filter cover...

Page 7: ...ut by an authorised customer service centre for Powerplus tools You can always obtain more information at the number 00 32 3 292 92 90 Any transportation costs shall always be borne by the customer unless agreed otherwise in writing At the same time no claim can be made on the warranty if the damage of the device is the result of negligent maintenance or overload Definitely excluded from the warra...

Page 8: ... accompanied by proof of purchase 12 ENVIRONMENT Should your appliance need replacement after extended use do not discard it with the household rubbish but dispose of it in an environmentally safe way Waste produced by electrical machine items should not be handled like normal household rubbish Please recycle where recycle facilities exist Check with your Local Authority or retailer for recycling ...

Page 9: ...ication of the apparatus voids this declaration European Directives including if applicable their amendments up to the date of signature 2011 65 EU 2014 30 EU 2006 42 EC 2000 14 EC Annex VI LwA measured 76dB A guaranteed 79dB A Testing Authority Eurofins Italy European harmonized standards including if applicable their amendments up to the date of signature EN1012 1 2010 EN60204 1 2018 EN55014 1 2...

Reviews: