Technical specifications.
4
Incandescent
Fluorescent
Exhaust fans /
small motors
LED
CFLs
Electronic
transformers
Standard iron core &
toroidal transformers
Compatible load types
Rated Loads
5AX
max
5A
max
3 Wire
with
Neutral
Mode
2 Wire
without
Neutral
5AX
max per channel,
10AX
total max load
5AX
max per channel,
channel 1 is 5A only.
See note below.
2 or 3 Wire Mode with Auto-Sensing.
5
2 Wire
without
Neutral
3 Wire
with
Neutral
NEUTRAL
LINE
LO
AD 1
LO
AD 4
LO
AD 3
LO
AD 2
NEUTRAL
ACTIVE
LO
AD 1
NEUTRAL
LINE
LO
AD 1
LO
AD 4
LO
AD 3
LO
AD 2
NEUTRAL
ACTIVE
Always use a Neutral wire where possible.
When operating without a neutral
connected, a small amount of power is used via LOAD 1 when switched off. This
may in some instances result with lights not completely turning off.
Dimmable
loads
might be fixed by increasing to at least 2 lights with a load >10W.
Non-Dimmable
loads may require a bypass/load correction device fitted if the load is insufficient.
Pair and setup with Zimi.
6
• Download the Zimi App.
• Choose ‘Add Device’.
• Follow the on screen instructions.
Zimi App Download
Point your phone
camera at the QR code
to open the app store.