Grounding Instructions 

 

Electrical connections must be made by a qualified electrician in compliance with 

all relevant codes. This machine must be properly grounded to help prevent electrical shock and 
possible fatal injury.

 

In the event of a malfunction or breakdown, grounding provides a path of least resistance for electric 
current to reduce the risk of electric shock. This tool is equipped with an electric cord having an 
equipment-grounding conductor and a grounding plug. The plug must be plugged into a matching outlet 
that is properly installed and grounded in accordance with all local codes and ordinances. 

Do not modify the plug provided. If it will not fit the outlet, have the proper outlet installed by a qualified 
electrician. 

Improper connection of the equipment-grounding conductor can result in a risk of electric shock. The 
conductor, with insulation having an outer surface that is green with or without yellow stripes, is the 
equipment-grounding conductor. If repair or replacement of the electric cord or plug is necessary, do not 
connect the equipment-grounding conductor to a live terminal. 

Check with a qualified electrician or service personnel if the grounding instructions are not completely 
understood, or if in doubt as to whether the tool is properly grounded. Use only three wire extension cords 
that have three-prong grounding plugs and three-pole receptacles that accept the tool’s plug. 

Repair or replace a damaged or worn cord immediately. 

115 Volt Operation 

The Air Filtration Unit is ready to run at 115 volt operation. It is intended for use on a circuit that has an 
outlet and a plug similar to the one illustrated in Figure A. A temporary adapter, which looks like the 
adapter as illustrated in Figure B, may be used to connect this plug to a two-pole receptacle, as shown in 
Figure B if a properly grounded outlet is not available. The temporary adapter should only be used until a 
properly grounded outlet can be installed by a qualified electrician. 

This adapter is not applicable in 

Canada. 

The green colored rigid ear, lug, or tab, extending from the adapter, must be connected to a 

permanent ground such as a properly grounded outlet box, as shown in Figure B. 

        

 

Figure 

A      Figure 

 

If an extension cord is necessary, make sure the cord rating is suitable for the Air Filtration Unit’s listed 
amperage. An undersize cord will cause a drop in line voltage resulting in loss of power and overheating. 

Use the chart in Figure C as a general guide in choosing the correct size cord. If in doubt, use the next 
heavier gauge. The smaller the gauge number, the heavier the cord. 

 

Cord Length (115V operation) 

Cord Gauge

 

25 16 

AWG 

50 16 

AWG 

100 14 

AWG 

150 12 

AWG 

Figure C

Summary of Contents for PM1200

Page 1: ...ions and Parts Manual Air Filtration System Model PM1200 WMH TOOL GROUP Inc 2420 Vantage Drive Elgin Illinois 60124 Part No M 1791330 Ph 800 274 6848 Revision A 12 07 www powermatic com Copyright 2007 WMH Tool Group Inc ...

Page 2: ...or examination postage prepaid to a location designated by us For the name of the location nearest you please call 1 800 274 6848 You must provide proof of initial purchase date and an explanation of the complaint must accompany the merchandise If our inspection discloses a defect we will repair or replace the product or refund the purchase price at our option We will return the repaired product o...

Page 3: ...ns 7 Unpacking 8 Contents of the Shipping Container 8 Assembly 8 Installation 8 Controls and Features 8 Operation 9 Changing Filters 9 Transmitter Replacement 10 Hole Dimensions 10 Replacement Parts 11 Parts Breakdown for PM1200 Air Filtration System 12 Parts List for PM1200 Air Filtration System 13 Electrical Connections 14 ...

Page 4: ...e machine is properly grounded 10 Disconnect the filtration unit from the power source unplug before servicing or changing filters 11 Form a habit of checking to see that adjusting wrenches rags etc are removed from the machine before turning it on 12 If ceiling mounted bottom of filtration unit must be at least 7 feet from the floor 13 If ceiling mounted mounts must be anchored to building struct...

Page 5: ...ssories may be hazardous 24 Do not stand on the filtration unit Serious injury could occur if the unit tips over Familiarize yourself with the following safety notices used in this manual This means that if precautions are not heeded it may result in minor injury and or possible machine damage This means that if precautions are not heeded it may result in serious injury or possibly even death ...

Page 6: ...com Specifications Model Number PM1200 Stock Number 1791330 Efficiency of Outer Filter 99 of 5 micron particles Efficiency of Inner Filter 85 of 1 micron particles Remote Transmitter radio frequency Blower Speeds 3 Timer Settings hours 1 to 9 Cabinet Material 20 gauge steel Overall Dimensions L x W x H in 33 x 25 x 13 Sound Rating 3 28 feet High Speed 65 dB Medium Speed 58 dB Low Speed 52 dB Air F...

Page 7: ...t as to whether the tool is properly grounded Use only three wire extension cords that have three prong grounding plugs and three pole receptacles that accept the tool s plug Repair or replace a damaged or worn cord immediately 115 Volt Operation The Air Filtration Unit is ready to run at 115 volt operation It is intended for use on a circuit that has an outlet and a plug similar to the one illust...

Page 8: ...d position then tighten the hex nut against the cabinet with a 10mm wrench Installation The unit must be anchored to a building structure which will support a minimum of 100 pounds Never mount to surfaces such as dry wall false ceiling grids etc If mounting to ceiling make sure chain and ceiling hooks are properly rated for hanging this unit Clearance should be at least 7 feet from bottom of unit ...

Page 9: ...d or replaced periodically depending upon the amount of use and the environment of your shop Using clogged filters will diminish the overall efficiency of the unit The outer filter is disposable but its life can be extended by occasional use of a shop vac or compressed air to clean off the dust For maximum efficiency however a dirty outer filter should be discarded and replaced with a new one An o...

Page 10: ...smitter will need to be programmed for your Air Filtration Unit This is easily done as follows Figures 4 and 5 1 Start the Air Filtration Unit 2 On the Air Filtration Unit s control panel press and hold the Speed and Timer buttons simultaneously for 4 seconds until you hear a beep 3 Turn on the remote transmitter 4 You should now be able to operate the machine using the remote transmitter Figure 3...

Page 11: ...To order parts or reach our service department call 1 800 274 6848 Monday through Friday see our website for business hours www powermatic com Having the Model Number and Serial Number of your machine available when you call will allow us to serve you quickly and accurately ...

Page 12: ...12 Parts Breakdown for PM1200 Air Filtration System ...

Page 13: ...Switch Label 1 17 7 PM1200 1707 Thermos Switch 5A 1 17 8 TS 1533042 Phillips Pan Head Machine Screw M5x12 1 17 9 PM1200 1709 Wiring Nut P2 1 17 10 PM1200 1710 Strain Relief 1 17 11 PM1200 1711 Power Cord 18AWGx3C 1 18 PM1200 18 Tapping Screw M4x6 4 19 PM1200 19 Concave Handle 2 20 PM1200 20 RF Transmitter Assembly 1 20 1 PM1200 2001 RF Transmitter 1 20 2 PM1200 2002 Holder 1 20 3 PM1200 2003 Wood ...

Page 14: ...nt Filters Stock No Description 1791082 Inner Filter PM1200 1791083 Outer Filter PM1200 1791084 Charcoal Diffusion Filter PM1200 optional 1791085 Washable Electrostatic Filter PM1200 optional Electrical Connections ...

Page 15: ...15 ...

Page 16: ...16 WMH Tool Group Inc 2420 Vantage Drive Elgin Illinois 60124 Phone 800 274 6848 www wmhtoolgroup com ...

Reviews: