Important Instructions About Boiler Room:
Th
t
t b
i
t lik
t
t t
t
i th b il
The ceiling of the boiler room can be isolated for sound and heat isolation. The position and place of the boiler is important
for sound isolation of the boiler.
Boiler room must have a good lighting and control switches of lighting must be outside of the boiler room.
There must not be any other equipments such as aspirator, air condition central etc. in the boiler rooms. These kind of
equipments can make vacuum effect and defect boilers pull force. This can cause burner failures.
Children must not enter to the boiler room. A second key must be kept in safe place for urgent matters.
Gas alarm equipments must be placed to the proper highth as mentioned on standards.
No one except the responsible person should get in to the boiler room.
There must not be equipments like water pump,contactor etc.. in the boiler room.
Fuel tanks must be put in another place which is rounded by walls.Natural air conditioning is needed for this place.
There must not be any kind of explosive , burning and flammable materials in the boiler room.
There must not be any kind of explosive burning and flammable gases in the boiler room atmosphere
Boiler room must be air conditioned by natural or other ways.
Humidity must be prevented in boiler room.
Boiler room must have the requested dimensions .
There must not be any kind of explosive , burning and flammable gases in the boiler room atmosphere.
For feeding water to the boiler,water line must be arranged near the boiler. And for filling out the water of the boiler in
necesarry conditions, there must be a connection to drainage in the system.
For the efficiency of the burner and the boiler,boiler room must be kept clean and dry.
If there are any electric keys, cables etc. Which can cause short circuits must be fixed, renewed as soon as possible.
In Natural Gas or LPG use ; boiler room,flue,system and plumbing issues must be under parameters of EN standarts and
gas offices orders. Rima is not responsible for any failure or problems that will be occured because of inadequate or not
sufficiently qualified conditions of boiler room, plumbing and other systems.
The instructions of local gas delivery must be applied.
Before painting , keep flammable materials out.
Boiler must not be installed on carpet.
Before any welding operation in boiler room, boiler must be stopped and the gas flow must be stopped by turning of the gas
valve.
Do not touch the boiler when it is hot.
Switch off the boiler immediately if there is danger of burning or explosion ( elecricity problem, gas leakage, liquid gas , etc.).