 7 

5.0

  Electrical connections 

 

Electrical  connections  should 

be made by a qualified electrician in compliance 
with  all  relevant  codes.  Failure  to  comply  may 
cause serious injury.  

The PM1250 Electrostatic AFS is prewired for single 
phase,  120V  power.  It  is  provided  with  a  plug 
designed for use on a circuit with a grounded outlet 
that looks like the one pictured in Figure 5-1. 

It is recommended that the PM1250 be connected 
to a dedicated 15 amp circuit with circuit breaker or 
fuse.  If  fuses  are  used,  they  should  be  time-delay 
fuse  marked  “D”. 

Local  codes  take  precedence 

over recommendations. 

IMPORTANT: 

This  electrostatic  unit  must  be 

electrically grounded for proper operation, as well as 
for safety reasons (see below). 

5.1

  GROUNDING INSTRUCTIONS 

1. All Grounded, Cord-connected Tools: 

This machine must be grounded. In the event of a 
malfunction  or  breakdown,  grounding  provides  a 
path of least resistance for electric current to reduce 
the risk of electric shock. This tool is equipped with 
an  electric  cord  having  an  equipment-grounding 
conductor and a grounding plug. The plug must be 
plugged  into  a  matching  outlet  that  is  properly 
installed and grounded in accordance with all local 
codes and ordinances. 

Do not modify the plug provided - if it will not fit the 
outlet, have the proper outlet installed by a qualified 
electrician. 

Improper  connection  of  the  equipment-grounding 
conductor can result in a risk of electric shock. The 
conductor  with  insulation  having  an  outer  surface 
that  is  green  with  or  without  yellow  stripes  is  the 
equipment-grounding  conductor.  If  repair  or 
replacement  of  the  electric  cord  or  plug  is 
necessary, do not connect the equipment-grounding 
conductor to a live terminal. 

 

Check 

with 

qualified 

electrician or service personnel if the grounding 
instructions are not completely understood, or if 
in  doubt  as  to  whether  the  tool  is  properly 
grounded. Failure to comply may cause serious 
or fatal injury. 

Use only 3-wire extension cords that have 3-prong 
grounding plugs and 3-pole receptacles that accept 
the tool's plug. 

Repair  or  replace  damaged  or  worn  cord 
immediately. 

2. Grounded, cord-connected tools intended for use 
on a supply circuit having a nominal rating less than 
150
 volts: 

This tool is intended for use on a circuit that has an 
outlet that looks like the one illustrated in Figure 5-
1.  

 

Figure 5-1 

5.2

  Extension cords 

The  use  of  extension  cords  is  discouraged.  Try  to 
position machines within reach of the power source. 
If an extension cord must be used, make sure it is 
heavy enough to carry the current your product will 
draw. An undersized cord will cause a drop in line 
voltage resulting in loss of power and overheating. 
Table  2  shows  correct  size  to  use  depending  on 
cord  length  and  nameplate  ampere  rating.  If  in 
doubt, use the next heavier gauge. The smaller the 
gauge number, the heavier the cord. 

Ampere 
Rating 

Volts 

Total length of cord in feet 

More 
Than 

Not 
More 
Than 

120 

25 

50 

100 

150 

 

AWG 

0

0

 

18 

16 

16 

14 

0

10 

 

18 

16 

14 

12 

10 

12 

 

16 

16 

14 

12 

12 

16 

 

14 

12 

Not 
Recommended 

 

Extension Cord Recommendations 

Table 2 

 

 

Summary of Contents for 1791331

Page 1: ...matic com Copyright 2021 Powermatic This product earned the ENERGY STAR by meeting strict energy efficiency guidelines set by the US EPA US EPA does not endorse any manufacturer claims of healthier indoor air from the use of this product The energy efficiency of this ENERGY STAR qualified model is measured based on a ratio between the model s CADR for dust and the electrical energy it consumes or ...

Page 2: ...ould occur if the unit tips over 12 Do not use this air filtration unit with a damaged cord or plug If the unit is not working as it should has been dropped damaged left outdoors or dropped into water return it to a service center 13 If ceiling mounted bottom of filtration unit must be at least 7 feet from the floor 14 If ceiling mounted mounts must be anchored to building structure which will sup...

Page 3: ... receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help This device complies with Industry Canada s license exempt RSSs Operation is subject to the following two conditions 1 This device may not cause interference and 2 This device must accept any interference including inte...

Page 4: ...peration and maintenance procedures for the PM1250 Electrostatic Air Filtration System This manual contains instructions on installation safety precautions general operating procedures maintenance instructions and parts breakdown Your machine has been designed and constructed to provide consistent long term operation if used in accordance with the instructions set forth in this document If there a...

Page 5: ...ge draw High speed 0 31 A Medium speed 0 19 A Low speed 0 13 A Filter diameter 543 mm 21 3 in Approximate filter life 3000 operating hours Programmed cleaning alert flashing red indicator 1000 operating hours Remote control batteries 2 AAA Overall dimensions WxHxD 27 x 25 5 8 x 15 in 688 x 650 x 380 mm Shipping dimensions LxWxH 29 x 28 1 2 x 14 in 738 x 725 x 355 mm Net weight approx 38 lb 17 3 kg...

Page 6: ...rent at time of publication but because of our policy of continuous improvement Powermatic reserves the right to change specifications at any time and without prior notice without incurring obligations 4 1 PM1250 mounting hole pattern Figure 4 1 ...

Page 7: ...e conductor with insulation having an outer surface that is green with or without yellow stripes is the equipment grounding conductor If repair or replacement of the electric cord or plug is necessary do not connect the equipment grounding conductor to a live terminal Check with a qualified electrician or service personnel if the grounding instructions are not completely understood or if in doubt ...

Page 8: ...utton to start unit Speed indicator light glows green and default speed is selected 3 Press and release Speed button until desired speed indicator is green 4 Press Timer button until desired timer indicator is green If Timer button is not pressed again for 3 seconds the selected time indicator will flash multiple times then stay green 5 Unit will count down from the corresponding time and will aut...

Page 9: ...e unit To install cleaned or replacement filter 6 Center filter onto stator and turn it clockwise about 1 8 of a turn until it fully engages you will feel a hard stop 7 Install cover and rotate clockwise until it fully engages A lock unlock graphic is molded into left and right edges of the cover as a guide Note A sensor prevents unit from starting if cover is not installed properly 8 Plug in unit...

Page 10: ...10 Figure 8 1 Assembly Figure 8 2 Controls Figure 8 3 Remote control Figure 8 4 Filter replacement ...

Page 11: ...Motor imbalance Have motor tested by qualified personnel replace if needed Unit not responding to remote control Weak batteries in remote control Replace batteries Radio frequency interference Identify sources of interference and eliminate them or relocate unit Remote control or machine control panel malfunction Contact Powermatic customer service Unit not working efficiently not cleaning air Filt...

Page 12: ... J1000 01 Display Board 1 11 2102 J1000 01 Mid Frame 1 12 2114 J1000 01 Control Button Set 1 13 1812 J1000 01 Control PCBA 1 14 2205 J1000 01 Grounding Connector 1 15 7201 J1000 01 High Voltage Unit 1 16 2105 J1000 01 Power Box Top 1 17 1811 J1000 01 Power PCBA 1 18 2106 J1000 01 Power Box Bottom 1 19 1813 J1000 02 Switch PCBA 1 20 1821 J1000 01 Motor 35W DC 140V 165V 1 21 2110 J1000 01 Motor Cove...

Page 13: ...13 11 1 2 PM1250 Electrostatic AFS Exploded View ...

Page 14: ...14 12 0 Electrical connections for PM1250 ...

Page 15: ...f a product requires further inspection the Technical Service representative will explain and assist with any additional action needed Powermatic has Authorized Service Centers located throughout the United States For the name of an Authorized Service Center in your area call 1 800 274 6846 or use the Service Center Locator on the Powermatic website More Information Powermatic is constantly adding...

Page 16: ...16 427 New Sanford Road LaVergne Tennessee 37086 Phone 800 274 6848 www powermatic com ...

Reviews: