Powermate 200-2756 E103733 Operator'S & Parts Manual Download Page 13

13

200-2756

Oilless air compressors are factory lubricated for life and do not
require any oil.

The basic components of the air compressor are the electric
motor, pump, pressure switch, and tank.

The 

electric motor

(see 

A

) powers the pump. The electric

motor is equipped with an overload protector and an automatic
reset. If the motor becomes overheated, the overload protector
will shut it down to prevent damage to the motor. When the
motor sufficiently cools, it will automatically reset.

The 

pump

(see 

A

) compresses the air and discharges it

into the tank.

The 

tank

(see 

B

) stores the compressed air.

The 

pressure switch

(see 

C

) shuts down the motor when

the air pressure in the tank reaches the kick–out pressure. As
compressed air is used and the pressure level in the tank drops
to the kick–in pressure, the pressure switch restarts the motor
automatically, without warning, and the pump resumes
compressing air.

Les compresseurs d’air sans huile sont lubrifiés à l’usine et ne
requièrent aucun huilage.

Les éléments de base du compresseur d'air sont le moteur

électrique, la pompe, le manostat et le réservoir.

Le 

moteur électrique

(

A

) actionne la pompe. Le moteur

électrique est équipé d’un limiteur de surcharge à
réenclenchement automatique. Si le moteur surchauffe, le
limiteur coupe l’alimentation pour éviter d’endommager le
moteur. Lorsque le moteur est suffisamment refroidi, il
redémarre automatiquement.

La 

pompe

(

A

) comprime l'air.

Le 

réservoir

(

B

) contient l'air comprimé. 

Le 

manostat

(

C

) arrête le moteur quand la pression

atmosphérique dans le réservoir atteint la pression de kick-out.
Au fur et à mesure que l'air comprimé est utilisé et que le
niveau de pression dans le réservoir baisse jusqu'à la pression
d'ouverture, le manostat remet le moteur en marche
automatiquement, sans avertissement, et la pompe reprend la
compression d'air.

Los compresores de aire sin aceite se lubrican en fábrica para
toda su vida útil, y no requieren aceite.

Los componentes básicos del compresor de aire son el

motor eléctrico, la bomba, el interruptor de presión y el tanque.

El 

motor eléctrico

(vea 

A

) acciona la bomba. El motor

eléctrico está equipado con un protector contra sobrecargas y
un reajuste automático. Si el motor se sobrecalienta, el
protector contra sobrecargas lo apagará para evitar que sufra
daños. Cuando el motor se enfríe lo suficiente, volverá a
arrancar automáticamente.

La 

bomba

(vea 

A

) comprime el aire y lo descarga hacia el

tanque.

El

tanque

(vea 

B

) almacena el aire comprimido. 

El 

interruptor de presión

(vea 

C

) apaga el motor cuando

la presión de aire en el tanque alcanza la presión de la
desconexión. Al ir usándose el aire comprimido y bajar el nivel
de presión en el tanque hasta llegar al nivel preestablecido, el
interruptor de presión vuelve a arrancar el motor y la bomba
continúa comprimiendo el aire.

OVERVIEW \ VUE D’ENSEMBLE \ RESUMEN GENERAL

BASIC AIR COMPRESSOR COMPONENTS

ÉLÉMENTS DE BASE DU COMPRESSEUR D’AIR

COMPONENTES BÁSICOS DEL 

COMPRESOR DE AIRE

Fig. 1

Summary of Contents for 200-2756 E103733

Page 1: ...en este manual antes de utilizar esta unidad Si no cumple con las instrucciones de este manual podr a ocasionar lesiones personales da os a la propiedad y o la anulaci n de su garant a El fabricante N...

Page 2: ...e lectrique 16 Rallonges 16 Instructions de mise la terre 16 MODE D EMPLOI 18 Mise en marche quotidienne 18 Arr t 18 BOUTON DE R INITIALISATION 20 ENTRETIEN 21 Vidange du r servoir 21 V rification de...

Page 3: ...ication A moment of inattention while operating power tools may result in serious personal injury Dress properly Do not wear loose clothing or jewelry Contain long hair Keep your hair clothing and glo...

Page 4: ...he tool with air connected can result in unexpected firing and possible serious personal injury Always follow all safety rules recommended by the manufacturer of your air tool in addition to all safet...

Page 5: ...Des quipements de s curit assurant une protection compl mentaire seront requis dans certains environnements Par exemple la zone de travail peut inclure une exposition un niveau de bruit qui risque de...

Page 6: ...Si l appareil ne vas pas tre utilis pendant un certain temps il est recommand de laisser le robinet de purge ouvert jusqu la prochaine fois que vous utiliserez l outil Ceci permettra l humidit de dis...

Page 7: ...out dispositif de protection ou autre composant endommag doit tre v rifi soigneusement afin de d terminer s il peut continuer fonctionner correctement et remplir sa fonction pr vue Inspectez l alignem...

Page 8: ...En algunos entornos se requiere protecci n adicional Por ejemplo en el rea de trabajo puede haber exposici n a un nivel de ruido que puede da ar el o do El patr n y el operador deben asegurarse de con...

Page 9: ...e rociado debe estar bien ventilada No fume mientras est rociando con pistola ni roc e donde haya presentes chispas o flamas Mantenga los compresores tan lejos del rea de pintura y de vapores explosiv...

Page 10: ...otra condici n que pudiera afectar su funcionamiento Toda protecci n o pieza que est da ada debe repararse apropiadamente o reemplazarse en un centro de servicio autorizado Con el cumplimiento de esta...

Page 11: ...c motor exceeds a predetermined limit GLOSSAIRE TERMINOLOGIQUE Filtre air l ment poreux contenu l int rieur d un logement en m tal ou en plastique attach la culasse du cylindre du compresseur pour ret...

Page 12: ...resi n actual en el conducto La presi n del conducto se ajusta girando la perilla de regulaci n de presi n Motor el ctrico Es el dispositivo encargado de suministrar la fuerza rotatoria necesaria para...

Page 13: ...automatiquement La pompe A comprime l air Le r servoir B contient l air comprim Le manostat C arr te le moteur quand la pression atmosph rique dans le r servoir atteint la pression de kick out Au fur...

Page 14: ...e sont pas en service pour r duire les probl mes de lubrification de d marrage du moteur et de gel de l eau produite par condensation d Enlever le compresseur de la carton et le placer sur une surface...

Page 15: ...e manom tre mesure le niveau de pression d air dans le r servoir L utilisateur ne peut pas r gler ce manom tre et il n indique pas la pression dans la conduite R gulateur de pression d air voir D Le r...

Page 16: ...ment sur une prise de courant mise la terre N utilisez pas de rallonge sauf n cessit absolue Utilisez plut t un tuyau flexible plus long pour atteindre la zone o l air est n cessaire S il l utilisatio...

Page 17: ...iene un alambre de conexi n a tierra con su enchufe correspondiente El enchufe debe conectarse en un tomacorriente que est bien instalado y conectado a tierra de acuerdo con todos los c digos y ordena...

Page 18: ...ation La pompe et le moteur lectrique produisent des temp ratures lev es Pour viter les br lures et autres blessures NE touchez PAS le compresseur quand il est en marche Laissez le refroidir avant de...

Page 19: ...ta que sobrepase el ajuste deseado despu s gire a la derecha hasta alcanzar la presi n deseada No exceda la presi n de operaci n de la herramienta o del accesorio que est usando 5 Ajuste el regulador...

Page 20: ...caus par l un des facteurs suivants Tension faible Manque de ventilation ad quate la temp rature de la pi ce est trop lev e Le calibre du fil est incorrect ou le cordon de rallonge est trop long Pour...

Page 21: ...orrosion depuis l int rieur du r servoir cette condensation doit tre vacu e la fin de chaque journ e de travail Veillez porter des lunettes de protection Soulagez la pression atmosph rique dans le sys...

Page 22: ...de d charge pour lib rer toute la pression dans le r servoir vacuez toute l humidit du r servoir Couvrez tout l appareil pour le prot ger de l humidit et de la poussi re Tire de la v lvula de alivio t...

Page 23: ...arge enough SOLUTION POSSIBLE CAUSE Low pressure or not enough air or Compressor does not stop Air leaks from regulator or regulator does not regulate pressure Regulated pressure gauge reading drops w...

Page 24: ...La valve de robinet de vidange de r servoir est ouverte SOLUTION CAUSE POSSIBLE V rifier les raccords l eau savonneuse Resserrer ou tanch ifier les raccords NE PAS TROP SERRER Fuite des raccords Nett...

Page 25: ...es mayor que el volumen por minuto CFM y la presi n suministrados por el compresor necesita un compresor m s grande La mayor a de los accesorios est n clasificados a un 25 del volumen real por minuto...

Page 26: ...26 200 2756 PARTS DRAWING DESSIN DES PI CES ESQUEMA DE LA PIEZAS PL1582019 20 GALLON VERT AND PL1582619 26 GALLON VERT Item 44...

Page 27: ...essure Switch 26 Gal Interrupteur Man metro 26 032 0109 2 Gauge 1 5 Manom tre Man metro 27 019 0263 1 Regulator Round R gulateur Regulador 28 036 0084 1 Quick Connect Steel Raccord rapide Acoplador es...

Page 28: ...28 200 2756 PARTS DRAWING DESSIN DES PI CES ESQUEMA DE LA PIEZAS PP1581719 17 GALLON HORIZONTAL Item 43...

Page 29: ...Rondelle Arandela 24 094 0184 1 Vibration Pad Tampon Almohadilla 25 N A 1 Bolt m8 x 1 25 x 30mm Boulon Perno 26 112 0168 1 Handle Poign e Empu adura 27 N A 1 Handle Grip Rubber 1 Poign e de poign e Ap...

Page 30: ...30 200 2756 PARTS DRAWING DESSIN DES PI CES ESQUEMA DE LA PIEZAS PUMP MOTOR ASSY F2B2 040 0420...

Page 31: ...1 Screw m5 x 0 8 x 25 Vis Tornillo 11 N A 1 Nut m5 x 0 8 crou Tuerca 12 N A 1 Screw m6 x 1 x 35mm Vis Tornillo 13 1 Eccentric Excentrique Exc ntrico 14 027 0051 1 Fan Ventilateur Ventilador 15 N A 1...

Page 32: ...z la date d achat au dessus de dans les espaces r serv cet effet Conservez votre re u et ce manuel pour r f rence ult rieure Quand vous avez besoin des services de l usine s il vous pla t contactez au...

Reviews: