Powerhouse M 8539 Quick Start Manual Download Page 4

%

Battery

Voltage

Battery

Capacity

Battery

Start Power

Alternator

output

Battery Anatysing

TEST

SET

%

Pressing the Auto Charge function will automatically apply the fastest charge rate the battery connected can safely take.
With this mode selected`AUTO`is displayed on the LCD display

Charging is complete when 100% is displayed on the LCD screen 

Battery Charging Mode 

For standard battery charging at temperatures over 5C
Increases the battery voltage to 14.4v(standard vehicle)or 14.6v (start/stop vehicle).  

Winter Mode 

Used for charging batteries at low temperatures(-20C to +5C). Increases the battery voltage to 14.6v
(standard vehicle) or 14.8v(Start/Stop vehicle).

Recondition Mode 

Applies a controlled increased charging voltage to allow recovery of deeply discharged batteries

Maintenance Mode 

Applies to low 0.8A charging rate, ideal for long term seasonal connection

1.Press the navigation arrows to select the battery charging icon and press SET.

*Default charging modes

Battery analysing modes operate with and without AC mains supply. Connecting the battery clips to the battery
automatically activates the charger

2.Press the navigation arrows to select the required charging mode and press SET.
   Pressing EXIT at any stage takes you to the 

rst stage of the menu process.

Battery Voltage

Battery Start Power

Alternator Output

Battery Capacity

√*

Battery Voltage mode
Displays the battery voltage as a %of its capacity:  

Press the navitgation arrows to select the battery % icon and press SET.  

12.7v-100%       12.4v-80%         12.2v-60%         11.9v-40%         11.6v-20%
12.5v-90%         12.3v-70%         12.1v-50%         11.8v-30%         11.3v-10%

%

SET

+

1.  

Battery Start Power
Assesses battery cranking power and recovery. Measures the voltage drop during engine starting to identify potential
starting problems due to battery failure.

SET

+

1.

2.

3.

4.  

A1+              With A1 displayed press SET - measures static battery voltage

A2+              With A2 displayed start the vehicle engine.

Min battery voltage recorded during cranking displayed and good, check or bad status displayed
Good>8v, check 7-8v and bad <7v

SET

A

 

Assesses battery caranking power and recovery. Measures the voltage drop during engine starting to identify potential
starting problems due to battery failure.

SET

1.           +           = A1 displayed

2.            (Rev engine to 3000rpm*)+            Maintain revs during 10 second countdown

SET

3.  A2 displayed(Rev engine to 2000rpm**)+           Maintain revs during 10 second countdown

SET

4. Battery voltages then displayed for both 3000rpm and 2000rpm tests
    Good or bad status displayed

* 3000rpm with no battery loading. i.e. no lights AC, etc
**2000rpm with battery loading. i.e. no lights AC, etc 

 

8

Operation- Battery Charging

9

Operation- Battery Analysing

6

10

Operation- Battery Analysing

7

4.

5.  

Reviews: