In order to fully disconnect the UPS system, first press the Standby switch then disconnect the
mains lead
Ensure that no fluids or other foreign objects can enter the UPS system.

Maintenance, servicing and faults

The UPS system operates with hazardous voltage. Repair may be carried out only by qualified
maintenance personnel.

Caution

 - risk of electric shock. Even some the unit is disconnected with the mains power

supply (building wiring socket outlet), components inside the UPS system are still connected
to the battery and are still electrically live and dangerous.
Before carrying out any kind of servicing and/or maintenance, disconnect the batteries and
verify that no current is present and no hazardous voltage exist in the terminals of high capa-
bility capacitor such as BUS-capacitors.
Only persons adequately familiar with batteries and with the required precautionary measures
may exchange batteries and supervise operations. Unauthorized persons must be kept away
from the batteries.

Caution

 - risk of electric shock. The battery circuit is not isolated from the input voltage. Haz-

ardous voltages may occur between the battery terminals and the ground. Before touching
any operation, please verify that no voltage is present!
Batteries may cause electric shock and have a high short-circuit current. Please take the
precautionary measures specified below  when working with batteries:

- remove wristwatches, rings and other metal objects
- use only tools with insulated grips and handles.

When exchange batteries, install the same number and type of batteries.
Do not attempt to dispose of batteries by burning them. This could cause battery explosion.
Do not open or destroy batteries. Escaping electrolyte can cause injury to the skin and eyes. It
may be toxic.
Please replace the fuse only with a fuse of the same type and  amperage in order to avoid fire
hazards.

3

Summary of Contents for UQ11-RM

Page 1: ...ER MANUAL Uninterruptible Power Supply ERENK Y MAH ANKIRI SK NO 1 1 ATA EH R STANBUL TEL 90 216 574 1 574 FAX 90 216 574 71 14 E MAIL info powerguard com tr www powerguard com tr UQ11 RM 1 10Kva model...

Page 2: ...tem Description 4 3 1 Front Panel 4 3 2 Rear Panel 7 4 Maintenance 9 4 1 Operation environment 9 4 2 Battery Application 9 4 3 Troubleshooting 9 5 Technical Data 12 5 1 Electrical Specifications 12 5...

Page 3: ...store data and shut down your network operating system before the battery is fully discharged whether you re there or not It provides perfect protection specifically for fileservers minicomputers Inte...

Page 4: ...ated by any individuals with no previous technical experience Following for 1KR XL 2KR XL 3KR XL special Assure to connect with the earth reliably The building wiring socket outlet shockproof socket o...

Page 5: ...batteries and with the required precautionary measures may exchange batteries and supervise operations Unauthorized persons must be kept away from the batteries Caution risk of electric shock The bat...

Page 6: ...3 1 DISPLAY PANEL 3 SYSTEM DESCRIPTION 4...

Page 7: ...5...

Page 8: ...6...

Page 9: ...K S Intelligent slot Output terminal Surge protection Input breaker External battery socket Output socket Communication port Output fuse Input socket Communication port Surge protection Intelligent sl...

Page 10: ...rt socket Intelligent slot terminal External battery Fan Surge protection Port maintenance Input output Communication 6KR Input output terminal Parallel port Intelligent slot External battery socket b...

Page 11: ...et the breaker External Battery Socket Special cable is offered for the battery pack insert one end into the external battery socket on the UPS the other to the battery pack the same packs can be para...

Page 12: ...10...

Page 13: ...4 4 OPERATING MODE FOR ALL MODELS 11...

Page 14: ...S mode 5A 10A S mode 12A 15 A S mode 15A 50A 32A OUTPUT Power rating 1kVA 0 7k W 2kVA 1 4kW 3kVA 2 1kW 10kVA 7kW 6kVA 4 2kW C A V 0 4 2 0 3 2 0 2 2 e g a t l o V Frequency 50 60x 1 0 2 Hz Battery Mod...

Page 15: ...13...

Reviews: