PowerBoss 5,500 Watt Storm-Plus Generator
TROUBLESHOOTING
Problem
Cause
Solution
Engine is running, but
no AC output is
available.
1. Circuit breaker is open.
2. Poor connection or defective cord set.
3. Connected device is bad.
4. Fault in generator.
1. Reset circuit breaker.
2. Check and repair.
3. Connect another device that is in good
condition.
4. Contact Generac service facility.
Engine runs good but
bogs down when
loads are connected.
1. Short circuit in a connected load.
2. Generator is overloaded.
3. Engine speed is too slow.
4. Shorted generator circuit.
1. Disconnect shorted electrical load.
2. See “Don’t Overload the Generator” on
page 9.
3. Contact Briggs service facility.
4. Contact Generac service facility.
Engine will not start;
or starts and runs
rough.
1. Rocker switch set to “Off”.
2. Fuel valve is in the “Closed” position.
3. Low oil level.
4. Dirty air cleaner.
5. Out of gasoline.
6. Stale
gasoline.
7. Spark plug wire not connected to
spark plug.
8. Bad spark plug.
9. Water
in
gasoline.
10. Overchoking.
11. Excessively rich fuel mixture.
12. Intake valve stuck open or closed.
13. Engine has lost compression.
1. Set switch to “On”.
2. Turn fuel valve to the “Open” position.
3. Fill crankcase to proper level.
4. Clean or replace air cleaner.
5. Fill fuel tank.
6. Drain gas tank and fill with fresh fuel.
7. Connect wire to spark plug.
8. Replace spark plug.
9. Drain gas tank; fill with fresh fuel.
10. Set choke to “Off” position.
11. Contact Briggs service facility.
12. Contact Briggs service facility.
13. Contact Briggs service facility.
Engine shuts down
during operation.
1. Out of gasoline.
2. Fault in engine.
1. Fill fuel tank.
2. Contact Briggs service facility.
Engine lacks power.
1. Load is too high.
2. Dirty
air
filter.
3. Engine needs to be serviced.
1. See “Don’t Overload the Generator” on
page 9.
2. Replace
air
filter.
3. Contact Briggs service facility.
Engine “hunts” or
falters.
1. Choke is opened too soon.
2. Carburetor is running too rich or too
lean.
1. Move choke to halfway position till engine
runs smoothly.
2. Contact Briggs service facility.
Summary of Contents for 5500 Storm-Plus
Page 13: ...PowerBoss 5 500 Watt Storm Plus Generator 13 NOTES...
Page 14: ...14 PowerBoss 5 500 Watt Storm Plus Generator SCHEMATIC...
Page 15: ...PowerBoss 5 500 Watt Storm Plus Generator 15 WIRING DIAGRAM...
Page 16: ...16 PowerBoss 5 500 Watt Storm Plus Generator EXPLODED VIEW MAIN UNIT...
Page 29: ...29 PowerBoss 5 500 Watt Storm Plus Generador NOTAS...