![Power Products ALPHA C-20 Operating Manual Download Page 11](http://html1.mh-extra.com/html/power-products/alpha-c-20/alpha-c-20_operating-manual_1587613011.webp)
3. OPERATING GUIDE
ALPHA C-20/25 CHARGER – OPERATING MANUAL V1.0
Page 11
3.4 CHARGE TIME
3.4.1 TIMER UNIT SETTING
The Alpha C-25 has a built in timer, allowing charge time settings from 1 to 999
minutes.
3.4.2 CHARGE TIME SETTING
The charge time will be set based on the state of charge of the battery and at
which rate the battery is being charged.
A list of recommended charge times for the most common batteries can be in
Appendix C, but always refer to your battery manufacturer's maintenance manual
for the most accurate information.
C. SET TIMER
Set the timer by adjusting the thumb-dial to
the required charge time.
D. SELECT CHARGE MODE
Turn the Charge Mode Select knob to the
desired mode: 1) Constant potential 14.7
volts; 2) Constant current; or 3) Constant
potential 28.5 volts. If two batteries are to be
charged simultaneously, they will both be
charged using the selected charge mode.