9
9.
The Power Adapter comes packaged with your Aurora Logger with an Output Plug
attached. Cut the Output Plug using standard wire cutter and strip the two conductors
for connecting them to the Screw Terminal of the Aurora Logger. Attach the
conductor with white label, which is a po12 VDC cable, to Port 6 of the Aurora
Logger Screw Terminal. Attach the other solid black ground conductor to Port 5 of the
Aurora Logger Screw Terminal. See the figure below.
To Network via
Switch or Router
Screw Terminal Block
on Aurora Logger
Example
Inverter
Terminal Block
Positive (+)
Negative (-)
GND
120VAC/12DC
Converter/Adapter
Aurora Logger
Ground
+12VDC Power
Use Twisted Pair Wire
PVI-xxxx Indoor Series
PVI-x.x Outdoor Series
PVI-x.x Outdoor
Series (U.S.)
Termination Switch
Adapter
+12VDC Power
Ground