SETTING RS-485 ADDRESS AND GRID TYPE

LED INDICATORS AND LCD

START-UP AND GRID CONNECTION

 ADJUSTMENT OF DISCONNECT PARAMETERS

ARC FAULT DETECTION -A MODELS ONLY

TECHNICAL DATA TABLE

POWER DERATING

BCM.00163.0_AA

A two-line Liquid Crystal Display (LCD) located in the center of the front panel (Figure 8) provides inverter 

operating status and statistics, service messages, and alarm and fault indicators.
Three LED indicator lights on the left side of the display show system status:

• 

POWER LED

 (green) indicates the inverter is operating normally.

• 

ALARM LED

 (yellow) indicates a fault condition has been detected; a description will appear in the 

two-line display.

• 

GFI LED

 (red) indicates the inverter has detected a ground fault in the DC side of the PV system.

LED INDICATORS

PROGRAMMING

CONTROLS

TWO LINE

LCD DISPLAY

Figure 8: LED Indicators, controls, and two-line display

During operation the display cycles through available data points, updating every five seconds. Screens 

may be scrolled manually by pressing the UP and DOWN programming control keys (Figure 8).
Pressing the ESC key gives access to three main menus: 

Statistics - Settings - Info.

Use the UP and DOWN keys to scroll between the menus and press ENTER to make a selection. To return 

to the preceding menu, press the ESC key.
The 

Statistics

Settings

 and 

Info

 menus can be accessed with just the array connected. Some parameters 

(e.g. current, voltage, power, partial energy, lifetime energy etc.) are available only after grid connection.  

Based on individual installations, the following parameters may need to be configured 

prior to initial grid connection:

Based on individual installations, the following parameters may need to be configured prior to initial  

grid connection:

• 

The RS-485 bus address for daisy chain (Section 

9

),

• 

AC grid type if different from default (Section 

9

),

• 

Adjustments to default frequency and disconnection time (Section 

10

).

Complete descriptions of the data available on the display menus can be found in the full manual on the 

CD accompanying this guide or on the Power-One website.

For –A models only, an autotest circuit is included in the module design of Power-One’s DC ARC FAULT 

DETECTOR and INTERRUPTOR (AFDI) solution.  The AFDI performs a self-test when the system is started, 

(ie every morning when sunlight is sufficient for grid connection).   The inverter display shows the results 

of the self-test as described in section 

11

.

During normal operation, (while the inverter in connected to the grid), the input current is continually 

measured and analyzed. If a DC arc fault is detected, the inverter is disconnected from the AC grid and 

the error message 

“ARC FAULT E050”

 will be shown on the inverter display.

Press and hold the ESC  key for three seconds to clear the error which will start the self-test. If self-test 

results are OK (section 

11

), the inverter will re-connect to the AC grid. If the DC arc fault is still present, 

the self test will result in error message 

“AF Self Test E053”

.  Refer to the Troubleshooting section in the 

full technical manual for possible solutions to clear the error.

When the AFD protection trips continously an electrical arcing has taken place. In this 

case Power-One recommends a complete and accurate check of DC connections.

The AF self test can be manually started anytime using the disconnect procedure below:

1. 

Turn off the inverter (switching off both DC and AC switches) and,

2.

 Turn on both the DC and AC switches waiting for display communication of self-test result.

Once the inverter has been wired and connected to the grid, use the following procedures to disconnect:

1. 

Disconnect from the AC Grid by turning OFF the external AC switch or turning OFF the Over 

Current Protection Device (circuit breaker).

2.

 Disconnect the inverter from the PV array by turning OFF the external DC disconnect switch.

NOTE: When possible, turn off the AC switch first, however, there is no specific order for turning off 

the two switches.

WARNING: After shutdown, wait at least 10 minutes before removing guards or covers 

in order to allow devices inside the unit to cool and any electrostatic charges and 

parasitic voltages to be discharged.

When removing the inverter covers, always check voltage levels at the DC input 

terminals and the AC output cables to ensure no hazardous voltages are present.

When multiple units have been connected in a daisy chain, the individual address will need to be 

assigned 

prior to grid connection

 using the display menu. The grid default type, 240V Split Phase, can 

also be changed 

prior to grid connection

 using the display menu.

With only the array connected, set the inverter’s DC disconnect switch to ON. GREEN 

POWER LED will flash and YELLOW ALARM LED will be steady. The LCD will read 

“Missing 

Grid”

. Press ESC to open the menus. Use the DOWN key to scroll to 

Settings

, and press 

ENTER.

The Settings menu requires an access password.

Upon selecting 

SETTINGS

 the password screen will display; the default 

password is 

0000

.

Pressing ENTER four times loads four zeroes on the display and opens 

the submenu (Figure 9).

The LCD has two visible text lines and the UP and DOWN control 

keys are used to scroll through the menu items. An arrow on the left 

side of the display highlights the current selection. Move the arrow 

UP or DOWN to the desired selection and press ENTER to access the 

associated submenu (Figure 9). To return to the preceding menu, press 

the ESC key.

Address

 and 

Set Vgrid

 are described below for use in installation. 

Complete descriptions of the submenus can be found in the full 

manual.

Figure 9: Settings submenus

Address:

 Scroll to Address and press Enter to open the 

submenu. Address values are assigned manually using any 

value in the range [2 to 64]. Press the UP and DOWN keys to 

scroll through numbers and ENTER to select. Auto address = 1 

and can be used only once; default address is set at 2.

Set VGrid:

 Scroll DOWN to Set VGrid and press ENTER to 

open the submenu. To choose a grid connection different 

from the 240V Split-phase default, use the UP or DOWN 

key to move the arrow to the desired selection and 

press ENTER. A second display screen will open; press  

ENTER to confirm selection or ESC to cancel.

An inverter not in direct sunlight will output its maximum rated power up to at least 40C (almost 120F).  

Power reduction and temperature at which it occurs depend on many operating parameters other than 

ambient temperature, such as input voltage, grid voltage, and power available from the photovoltaic 

modules.  The inverter can decrease power output during certain periods of the day according to these 

parameters.

PVI-5000-OUTD-US

Operating ambient temperature at full power (without derating):   -25 °C...+ 60 °C

PVI-6000-OUTD-US

Operating ambient temperature at full power (without derating):   -25 °C...+ 60 °C

To adjust frequency and disconnect times to meet local utility requirements, modifications are made 

using the Aurora Manager-TL software. The software, with instructions to download and install on a 

PC, can be found on the CD included with this inverter. If an internet connection is available, check the 

product page at www.power-one.com/renewable-energy to download the most recent version of the 

software.

Prior to connecting to the grid, with the inverter’s DC disconnect switch set to ON

, a computer, with 

Aurora Manager-TL software installed, should be connected to the inverter via an RS-485-USB adapter 

(not included). The USB driver files and instructions for installation can be found on the CD included 

with the inverter or Power-One website. PC-inverter connection cable required is standard USB 2.0 cable, 

terminals type A and B.

Launch the application from the computer desktop icon. At 

Select Mode

 screen, enter the address 

assigned a single inverter and press 

Start

. For multiple inverters press 

Scan

 to search 

All Inverters

.

Grid parameters will be displayed. Default settings cause automatic disconnection from the grid in 

160ms when line frequency is outside the range of 59.3 Hz < f < 60.5 Hz. 

Press the Write button

 to 

change values of desired parameters to those required by the local utility.

After frequency and disconnect time values have been adjusted, turn DC power OFF and 

ON to save new data. Changes to parameters must be made to meet the requirements of 

the local utility. Entry of improper values could cause inverter to shut down.

Cond

.

Simulated utility source

Max.time (sec) at 60Hz

a

 

before cessation of current 

to the simulated utility

Voltage (V)

Frequency (Hz)

A

<0.50 V

nor

 

b

Rated (60Hz)

0.16 (Fixed)

B

0.50 V

nor

 

b

  ≤ V < 0.88 V

nor

 

(Adjustable)

Rated (60Hz)

2 (Fixed)

C

1.10 V

nor

 

b

 < V<1.20 V

nor

 (*) 

(Adjustable)

Rated (60Hz)

1 (Fixed)

D

1.20V

nor

 ≤ V (*)

Rated (60Hz)

0.16 (Fixed)

E

Rated

f > 60.5 Hz (Default)

(Adj. 60.2 to 63.0 Hz)

0.16 (Default)

(Adj. 0.16 to 300 sec)

F

Rated

f < 59.3 Hz (Default)

(Adj. 59.8 to 57.0 Hz)

0.16 (Default)

(Adj. 0.16 to 300 sec)

G

Rated

 f< 57.0 Hz

0.16 (Fixed)

H

Rated

f > 63.0 Hz

0.16 (Fixed)

Table 2: Voltage/Frequency tolerances for Utility Interaction required by UL1741

The procedure for START-UP is as follows:

• 

Set the inverter’s DC disconnect switch to ON.

• 

Set the AC disconnect switch to the inverter to ON.

Once both disconnects are closed, the inverter starts the grid connection sequence. These screens are 

initially displayed at start-up:

While the system checks for grid connection (Missing Grid) to be 

established, the ALARM LED turns steady YELLOW and the POWER 

LED flashes GREEN.

When waiting for sunlight (Waiting Sun) the POWER LED turns 

steady GREEN.  As soon as conditions are met, the inverter is 

connected to the grid.

For –A versions ONLY

, the display shows the AFD board self-test 

running and results upon connection. If the self-test results are 

OK, the inverter will continue to Next connections.

If a potential problem on the AFD board is detected, the self-test 

will result in error. Refer to the Troubleshooting section in the full 

technical manual for possible solutions to clear the error.

All versions

 will display the following screens during connection: the time (seconds) remaining to 

complete the output voltage and frequency values check, and whether the values are within range.

A final display screen for insulation resistance (RISO) is displayed.  

If all items described above test OK, the inverter is connected to 

the grid and displays the message, 

“Inverter OK”

, along with the 

date and time.

Clock malfunctioning, or other non-function related faults that do 

not interfere with operation, may be shown instead of the date 

and time.

*  A

ll da

ta is subjec

t t

o change without notic

**I

nv

er

ter c

an apply tha

t much curr

en

t – Br

eak

er will op

en

3

A

U

RO

RA

 UN

O

St

an

da

rd

 - 

W

ith

 D

Sw

itc

- F

lo

at

in

Ar

ra

an

Ar

c F

au

lt 

D

et

ec

tio

(A

FD

)  

    

    

    

  

    

   P

VI

-5

00

0-

O

U

TD

-U

S-

    

    

    

    

    

    

    

    

    

    

    

   P

VI

-6

00

0-

O

U

TD

-U

S-

A

TE

CHNI

C

A

D

AT

A

VA

LUE

S

PV

I-5000

-O

U

TD

-US

PV

I-6000

-O

U

TD

-US

Nominal 

O

utput 

Po

w

er

W

5000

6000

M

aximum 

O

utput 

Po

w

er

W

5000

6000

Ra

ted 

Grid 

AC

 V

oltage

V

208

240

277

208

240

277

Input 

Side (D

C)

N

um

ber of 

Inde

pende

nt MPPT

 

Channels

2

2

M

aximum 

Usable 

Po

w

er

 

for 

Each 

Channel

W

4000

4000

Absolu

te 

M

aximum

 V

oltage 

(V

max)

V

600

600

Sta

rt- 

Up

 V

oltage

 (V

sta

rt)

V

200   (ad

j. 120-350 )

200   (ad

j. 120-350 )

Full 

Po

w

er 

MPPT

 V

oltage 

Range 

V

200-530

200-530

O

pe

ra

ting MPPT

 V

oltage 

Range 

V

0.7x

Vsta

rt

-580

0.7x

Vsta

rt

-580

M

aximum 

Cur

re

nt (

Idcmax) 

for 

both MPPT in 

Pa

rallel

A

36

36

M

aximum 

Usable 

Cur

re

nt 

per 

Channel

A

18

18

M

aximum 

Sho

rt 

Ci

rcuit 

Cur

re

nt 

Limit 

per 

Channel

A

22

22

N

um

ber of

 W

ire 

Landing

 Terminals 

Per 

Channel

Pairs

Pairs

Ar

ra

W

iring

 Termin

ation

Te

rminal bloc

k, 

Pr

essu

re Clam

p, 

AWG8

-A

WG4

O

utput 

Side (

AC

)

Grid 

Conne

ction

 Ty

pe

1Ø/2W

Spli

t-Ø/3W

1Ø/2W

1Ø/2W

Spli

t-Ø/3W

1Ø/2W

Adjustable

Voltage 

Range 

(V

min

-V

max) 

V

183-228 

211-264 

244-304 

183-228 

211-264 

244-304 

Grid 

Fr

equen

cy

Hz

60

60

Adjustable 

Grid 

Fr

equen

cy 

Range

Hz

57-60.5

57-60.5

M

aximum 

Cur

re

nt (

Iacmax)

A

RMS

27

23

20

30

28

24

Po

w

er 

Fa

ct

or

> 0.995

> 0.995

Total

 H

armonic 

D

is

to

rtion 

At 

Ra

ted 

Po

w

er

%

< 2

< 2

Co

ntribu

to

ry 

Fault 

Cur

re

nt**

A

pk

/A

RMS

36.25/25.63

36.5/25.81

31.75/22.45

36.25/25.63

36.5/25.81

31.75/22.45

Grid

 W

iring

 Termin

ation

 Ty

pe

Te

rminal bloc

k, 

Pr

essu

re Clamp

, A

WG8 - 

AWG4

Pr

ot

ec

tion D

evi

ces

Input Re

verse 

Polari

ty 

Pr

ot

ec

tion

Yes

Yes

O

ver

-V

oltage 

Pr

ot

ec

tion

 Ty

pe

Va

ris

to

r, 2 

for each channel

Va

ris

to

r, 2 

for each channel

PV 

Ar

ra

Gr

ound 

Fault De

te

ction

Pr

e sta

rt

-up 

Riso and dynamic GFDI 

(R

equi

res 

Flo

ating 

Ar

ra

ys)

Pr

e sta

rt

-up 

Riso and dynamic GFDI 

(R

equi

res 

Flo

ating 

Ar

ra

ys)

O

utput

An

ti-

Islanding 

Pr

ot

ec

tion

M

eets UL 1741/IEEE1547 

requi

reme

nts

M

eets UL 1741/IEEE1547 

requi

reme

nts

O

ver

-V

oltage 

Pr

ot

ec

tion

 Ty

pe

Va

ris

to

r, 2 

(L

1

 - L

2

 / L

1

 - G)

Va

ris

to

r, 2 

(L

1

 - L

2

 / L

1

 - G)

M

aximum 

AC

 O

CPD 

Ra

ting

A

35

30

25

40

35

30

E M

aximum 

E

%

97.1

97.1

CEC

 E

%

96

96.5

96.5

96

96.5

96.5

O

pe

ra

ting 

Pe

rf

orman

ce

Stand-

by 

Consumption

W

RMS

< 8

< 8

N

ig

ht time 

consumption 

W

RMS

< 0.6

< 0.6

Communi

ca

tion

User-

In

te

rfa

ce 

16 cha

ra

ct

ers x 2 lines 

LCD displ

ay

Remo

te 

M

oni

toring (1xR

S485 inc

l.)

AU

RO

RA

-UNIVERSAL (op

t.)

W

ired 

Lo

cal 

M

oni

toring  (1xR

S485 inc

l.)

PVI-US

B-RS485_232 (op

t.), PVI-DES

KT

OP (op

t.)

W

ireless 

Lo

cal 

M

oni

toring

PVI-DES

KT

OP (op

t.) with PVI-

RADIOMODULE (op

t.)

En

vi

ronme

ntal

Ambie

nt 

Air 

O

pe

ra

ting

 Tem

pe

ra

tu

re 

Range

°F (°

C)

-13 

to +140 (-25 

to +60)

-13 

to +140 (-25 

to +60)

with de

ra

ting ab

ov

e 122 (50)

Ambie

nt 

Air 

St

or

age

 Tem

pe

ra

tu

re 

Range

°F (°

C)

-40 

to 176 (-40 

to +80)

-40 

to 176 (-40 

to +80)

Rel

ati

ve 

H

umidi

ty

% RH

0-100  

condensing

0-100  

condensing

Ac

oustic 

Noise 

Emission 

Le

vel

db 

(A

) @1m

< 50

< 50

M

aximum 

O

pe

ra

ting 

Altitude without De

ra

ting

ft(m)

 6560 (2000) 

 6560 (2000) 

M

echani

cal 

S

Enclosu

re 

ra

ting

NE

M

A 4X

NE

M

A 4X

Co

oling

Na

tu

ral 

Co

nv

ec

tion

Na

tu

ral 

Co

nv

ec

tion

D

imensions (

H

 x

 W x 

D)

in (mm)

41.4 x 12.8 x 

8.6 (1052 x 325 x 218)

W

eig

ht

lb (kg)

< 59.5 (27.0)

< 59.5 (27.0)

Shipping

 W

eig

ht

lb (kg)

< 78 (35.4)

< 78 (35.4)

M

ou

nting 

Sy

st

em

W

all b

racket

W

all b

racket

Conduit 

Conne

ctions

Tr

ade Si

ze Kos: (2ea x 1/2”) 

and (2ea x 1-1/4

”, 3 pla

ces sid

e, f

ro

nt

, r

ear)

Tr

ade Si

ze Kos: (2ea x 1/2”) 

and (2ea x 1-1/4

”, 3 pla

ces sid

e, f

ro

nt

, r

ear)

D

Swi

tch 

Ra

ting

 (P

er 

Co

nta

ct)

A/V

25 / 600

25 / 600

Sa

fe

ty

Isol

ation 

Le

vel

Tr

ans

fo

rme

rless (

Flo

ating 

Ar

ra

y)

Tr

ans

fo

rme

rless (

Flo

ating 

Ar

ra

y)

Sa

fe

ty and 

EM

Standa

rd

UL 1741, CSA - C22.2 N. 107.1-01

UL 1741, CSA - C22.2 N. 107.1-01

Sa

fe

ty 

App

ro

val

c

CSA

us

c

CSA

us

W

ar

ra

nt

y

Standa

rd

 W

ar

ra

nt

y

years

10

10

Ex

tended

 W

ar

ra

nt

y

years

15 & 20 

15 & 20 

Av

ailable 

M

odels

Standa

rd -

 W

ith D

Swi

tch - 

Flo

ating 

Ar

ra

y

PVI-5000

-OUT

D

-US

PVI-6000

-OUT

D

-US

 

Reviews: