6
LCD (Digital Meter) DISPLAY GUIDE
Item Descriptions
O/P Voltage "V":
Default display
O/P Current, Charging Current "A":
The O/P current will display after pressing "Display Key" for 1 second
while displaying "V".
Press & hold “Display Key” for 3 seconds while displaying “A” to
enable O/P current “zero calibration” (the period approx. 10 seconds)
Press “Display Key” for 2 seconds to disable “zero calibration.”
(For safety concerns, zero calibration is not recommended)
Battery Level "P":
The percentage of battery capacity at the moment will display after
pressing "Display Key" for 1 second while displaying "A".
Total Charging Capacity "AH" (Ampere-Hour):
AH calculation will be initiated when charging current >1A, "H"
twinkles when “AH" is operating.
Press and hold "Display Key" for 3 seconds while displaying "H" to
enable AH to zero. "H" stops twinkling when "AH" function stops
operating.
Timer for AH "t":
Start counting after "AH" function is operating. This is to allow users to
know AH value within certain period of time.
Charging End Time Setting "E":
Initiates when voltage >setting value or charging current <30% of
rating. Press & hold "Display Key" for 3 seconds while displaying "E"
to enable timer setting. (Upper Bar twinkle: increase; Bottom Bar
twinkle: decrease)
Press and hold "Display Key" for 3 seconds to save the new setting
value. The 3
rd
dot signal flashes light means the timer is starting and
while the timer stops, the 3
rd
dot signal solid lights.