Output Voltage & Frequency Adjust 

A. In this screen, press Enter-key to 

enter the following steps for 

output voltage and frequency 

adjustment. 

 

 

 

B. The cursor (

) will pop up to 

indicate the output voltage and 

frequency newly selected. 

 

C. Use Up or Down-key to adjust 

the output voltage (if 220V 

configure, 220V, 230V, and 240V 

is selectable; if 110V configure, 

110V, 115V, and 120V is 

selectable). Press Enter-key to 

confirm voltage and then the 

cursor will move to frequency 

selection. The output frequency 

(50Hz or 60Hz) can be adjusted 

by the same key operation. 

 

D. Once the correct voltage is 

selected, press Enter-key again 

to save the selection. 

 

 

 

 

Summary of Contents for LC Series

Page 1: ...r Charge Controller Battery Charger UPS USER S MANUAL 800W 1600W 2400W 4000W 6000W 8000W 1 CONTENTS 1 INTRODUCTION 2 2 SAFTY INSTRUCTION 3 3 CABLE CONNECTION 5 4 SYSTEM DESCRIPTION 6 5 SOLAR INVERTER OPERATION 12 6 TROUBLE SHOOTING GUIDE 17 7 OPERATION MODES OF THE SOLAR INVERTER 19 8 SPECIFICATION OF SOLAR INVERTER 21 ...

Page 2: ... Mounted design 1 3 Important Notices 1 Read instructions carefully before operating the Solar Inverter 2 Solar Inverter power connect instruction should be followed 3 Please don t open the case to prevent danger 5 Retain the load within the rating of Solar Inverter to prevent faults 6 Keep the Solar Inverter clean and dry 3 2 SAFTY INSTRUCTION 2 1 Transporting 1 Disconnect all power cables if nec...

Page 3: ...lease take the precautionary measures specified below and any other measures necessary when working with batteries remove wristwatches rings and other metal objects use only tools with insulated grips and handles 5 3 CABLE CONNECTION 3 1 Inspection 1 The system may be installed and wired only by qualified electricians in accordance with applicable safety regulations 2 When installing the electrica...

Page 4: ...y It is pressed with the Down key to turn on the Solar Inverter In battery operation mode press it with Up key at the same time to disable the buzzer Beside it is pressed to confirm and enter the item selected 5 Fault LED red To indicate the Solar Inverter is in fault condition because of inverter shutdown or over temperature 7 6 Warning LED yellow To indicate the Solar Inverter is in the status o...

Page 5: ...8 1600W 2400W Rack Mount Type 9 800W Wall Mounted Type ...

Page 6: ...10 1600W 2400W Wall Mounted Type 11 4000W 6000W 8000W Wall Mounted Type ...

Page 7: ...the AC source is connected the LCD Display shall light up immediately to display first the main menu of greeting context and the Normal LED is blinking to indicate ready to switch on the inverter 2 By pressing the Enter key and the Down key simultaneously for 3 seconds the Solar Inverter will start up after two beeps and Normal LED lights up to indicate the power is from its inverter to the load 3...

Page 8: ...output voltage and frequency newly selected C Use Up or Down key to adjust the output voltage if 220V configure 220V 230V and 240V is selectable if 110V configure 110V 115V and 120V is selectable Press Enter key to confirm voltage and then the cursor will move to frequency selection The output frequency 50Hz or 60Hz can be adjusted by the same key operation D Once the correct voltage is selected p...

Page 9: ... SOLAR INVERTER STATUS POSSIBLE CAUSE ACTION 1 AC utility power is normal Solar Inverter is running normally but fault LED lits up Buzzer beeps continuously 1 Charger PCB is damaged 2 Fan is damaged 3 Unknown 1 Replace the charger PCB 2 Replace the fan 3 Restart UPS 3 AC utility power is normal but Solar Inverter is overloaded Warning LED lits up and buzzer beeps per second Overload 100 load 125 P...

Page 10: ...Solar Inverter will shut down automatically Please save data or turn off the loads soon 8 AC utility power fails Solar Inverter has shut down automatically Battery runs out Solar Inverter will restart up when AC utility power is restored 19 7 OPERATION MODES OF THE SOLAR INVERTER 7 1 Solar Inverter System Block Diagram 7 2 Normal Operation There are two main loops when AC utility is normal the AC ...

Page 11: ...y 50Hz 60Hz 45Hz 70Hz Line Low Transfer 120VAC 2 60VAC 2 Line Low Return 130VAC 2 65VAC 2 Line High Transfer 275VAC 2 135VAC 2 Input Voltage Range Line High Return 260VAC 2 130VAC 2 Voltage 220Vac 230V or 240VAC re settable via LCD panel 110Vac 115V or 120VAC re settable via LCD panel Voltage Regulation Batt Mode 3 RMS for entire battery voltage range Frequency 50Hz or 60Hz Frequency Regulation Ba...

Page 12: ...l WxHxD mm Wall Mounted 298 400 150 298 450 190 298 450 190 Feature on SLU models only Specifications are subjected to change without prior notice 23 Model PM 4000LC PM 4000SLU PM 6000LC PM 6000SLU PM 8000LC PM 8000SLU Capacity VA Watt 5KVA 4000W 6KVA 6000W 8KVA 8000W Nominal Voltage 220Vac 110Vac 220Vac only Acceptable Voltage Range 120 275Vac 60 135Vac 120 275Vac Frequency 50Hz 60Hz 45Hz 70Hz Li...

Page 13: ...current Temperature Model LED Normal Green Warning Yellow Fault Red Battery Mode Beeping every 4 seconds Low Battery Beeping every second Inverter Fault Beeping Continuously Audible Alarm Overload Beeping twice per second Operation Temperature 0 40 degree C 32 104 degree F Relative Humidity 0 95 non dondensing Environment Audible Noise Less than 55dBA at 1M Net Weigh Kgs 49 20 51 40 55 00 Physical...

Reviews: