A.  General Introduction 

We are experts in DC to AC Power Inverter and Solar Inverter. Our engineers are making use of 
advanced technological design that results in an inverter that is more excellent, smarter and 
easier to use than any other inverter with similar power ratings. We have been developed to 
provide you with years of trouble free operation. We provide a Pure Sine Wave output with very 
high quality power, often with less spikes and surges than grid-supplied power. 

Please take a few minutes to read this manual carefully. 

 
B.  Application 

Pure Sine Wave Power Inverters provide 150, 350, 650, 1200, 1800, 3000 and 6000 watts of 
Pure Sine Wave AC power from a DC source. 

 

C.  Features 

Capable of driving inductive loads, i.e., electric 
tools and appliances

 

Microprocessor-based design with accurate 
and stable frequency

 

Does not affect other equipment like TV, 
radio…etc

 

Standard outputs adjustable 100~120Vac, 
200~240Vac, 50/60Hz

 

Standard specially-designed AC and DC line 
filters

 

Panel indicators for battery voltage & load level 
(%)

 

Specific chassis for harsh environments

 

Standard inputs 12V, 24V (48V Custom design)

 

No problem with microwave ovens

 

Very low harmonic distortion, THD<3%

 

Standard low battery cut-off

 

Quick

 

response, standby functions

 

Great overload performance

 

Very efficient stand-by circuit

 

State-of-Art auto load sense

 

Can be used anywhere

 

Pure sine wave at 50~60Hz

 

Simplified system design

 

Lowest installation cost

 

Remote control unit 

Extremely efficient 

Green Power 

Easily mounted 

Reliable 

No noise 

 

 

D.  Safety Instructions 

 

 

 

 

 

 

1. 

General Safety Precautions

 

  Do not expose the Inverter to rain, snow, spray, bilge or dust.  

  To reduce risk of hazard, do not cover or obstruct the ventilation openings.  

  Do not install the Inverter in a zero-clearance compartment. Overheating may result.  

  To avoid a risk of fire and electronic shock, make sure that existing wiring is in good electrical 

condition and that wire is not undersized.  

  Do not operate the Inverter with damaged or substandard wiring.    

 
 

                    

 

WARNING! 

Before installing and using your inverter, read the Safety Instructions! 

 

Summary of Contents for 0150LN

Page 1: ...ser Manual Before install and use your Inverter read the User Manual and safety instructions 12V 24V 48Vdc Input 115V 230Vac Output 150W 6000W Output cont Cooler housing design Anytime Anywhere Power...

Page 2: ...ns 3 E Front View Main Functions 5 F Rear View Main Functions 7 G Pre Installation Information 8 H Electrical Requirements 8 I Installation Requirements 8 J Connection and Testing 10 K Operation 11 L...

Page 3: ...ard specially designed AC and DC line filters Panel indicators for battery voltage load level Specific chassis for harsh environments Standard inputs 12V 24V 48V Custom design No problem with microwav...

Page 4: ...ash immediately with soap and water If acid gets into eyes immediately flood eyes with running cold water for at least 20 minutes and get medical attention immediately NEVER smoke or allow a spark or...

Page 5: ...5 E Front View Main Functions 0150LN 0350LN 0650L 1200L 1800L 3000L 6000L...

Page 6: ...r Temp Over Temperature Protection Under Volt Under Voltage Protection Over Load Over Load Protection Power Power ON Run Green Power Indicates current operating condition of the inverter 3 AC outlet O...

Page 7: ...7 F Rear View Main Functions 0150LN 0350LN 0650L 1200L 1800L 3000L 6000L...

Page 8: ...plash on the inverter free of salt or moisture laden air Temperature Ambient air temperature should be between 0 and 40 Safety Do not install in a battery compartment or other areas where flammable fu...

Page 9: ...e inverter to a suitable surface paying close attention to the mounting requirements previously mentioned in this manual 2 AC Wiring Important to satisfy warranty requirements and conditions a qualifi...

Page 10: ...terminal on the inverter The connection to the negative NEG terminal of the Inverter should be the last connection made A spark when making this final connection is normal 3 Before proceeding further...

Page 11: ...olts to 16 volts for 12V models and 20 volts to 32 volts for 24V models and 42 volts to 62 volts for 48V models from 150Watts up to 6000Watts 2 Over voltage indicator The over voltage indicator indica...

Page 12: ...n is indicated by the inverter turning off after every eight to ten seconds then back on again The AC Status lamp will also be flashing orange There are two possible solutions Increase the sensitivity...

Page 13: ...mptoms Possible Cause Solution Low output voltage Using average reading Use true RMS and cable 110V 95 105VAC Voltmeter See page 7 Point 6 7 of manual 220V 190 210VAC Load LED flashes Overload Reduce...

Page 14: ...16 VDC 20 32 VDC 42 62 VDC 20 32VDC 42 62VDC Green Power Recovery Time 1 Second LED Status Indication RUN trip Green power LED All in one Power ON OFF RUN STAND BY High Low Battery Shutdown Over Tempe...

Reviews: