background image

TIP Sheet #176  

82-E0263-T REV. 1

1-03

T.I.P. 

T

roubleshooting 

I

nformation on 

P

ower Gear

Step 6) Extend room out to half way, and then do a full retract to initialize the controller. 

NOTE:

  If the slide

-

out is initially positioned past the half way point, it only needs to be fully 

retracted to initialize the controller.  

NOTE:

  Maximum motor amperage draw during room extension should be less than Maximum 

motor amperage during room retraction. 

NOTE:  

For troubleshooting information, see Power Gear Tip Sheet #173. 

Hookup Instructions for S/O Sensing Controller: 

POWER GEAR 

COMPNONENTS 

FLEETWOOD 

HOOKUPS 

SENSING CONTROLLER WIRING 

CONNECTIONS AND MOTOR 

OPERATING CONDITIONS 

operation 

MOTOR

 

CW 

CCW

connection  MOTOR RED 

GREEN 

MTR RED 

MTR BLACK 

connection  MOTOR BLACK 

YELLOW 

MTR BLACK 

MTR RED 

connection  SWITCH OUT 

BLUE 

SW. OUT 

SW. OUT 

connection  SWITCH IN 

ORANGE 

SW. IN 

SW. IN 

conn12 VDC

RED 

BATT. 

BATT. 

connection GROUND 

WHITE 

GND. 

GND. 

Operation assumes the switch is being pushed to the "IN" position. 

Connections assume the "SWITCH IN PIN" refers to the pin directly below 
the "OUT" position on the switch and “SWITCH OUT PIN” refers to the pin 
directly below the “IN” position on the switch. 