TIP Sheet #176
82-E0263-T REV. 1
1-03
T.I.P.
T
roubleshooting
I
nformation on
P
ower Gear
Step 6) Extend room out to half way, and then do a full retract to initialize the controller.
NOTE:
If the slide
-
out is initially positioned past the half way point, it only needs to be fully
retracted to initialize the controller.
NOTE:
Maximum motor amperage draw during room extension should be less than Maximum
motor amperage during room retraction.
NOTE:
For troubleshooting information, see Power Gear Tip Sheet #173.
Hookup Instructions for S/O Sensing Controller:
POWER GEAR
COMPNONENTS
FLEETWOOD
HOOKUPS
SENSING CONTROLLER WIRING
CONNECTIONS AND MOTOR
OPERATING CONDITIONS
operation
MOTOR
CW
CCW
connection MOTOR RED
GREEN
MTR RED
MTR BLACK
connection MOTOR BLACK
YELLOW
MTR BLACK
MTR RED
connection SWITCH OUT
BLUE
SW. OUT
SW. OUT
connection SWITCH IN
ORANGE
SW. IN
SW. IN
conn12 VDC
RED
BATT.
BATT.
connection GROUND
WHITE
GND.
GND.
Operation assumes the switch is being pushed to the "IN" position.
Connections assume the "SWITCH IN PIN" refers to the pin directly below
the "OUT" position on the switch and “SWITCH OUT PIN” refers to the pin
directly below the “IN” position on the switch.