Page
4
of
6
3010002678
Owner’s Manual Slim Rack Bunk Lift System
*
This tip sheet and other
updated troubleshooting
information can be found on
our website at
www.powergearus.com.
FIGURE 5 FAULT CODES
Fault
Code
Fault
Type
Description
Possible Cause
Possible Solutions
1
Major
Stops not programmed
•
Stops have not been set
•
Stops were cleared
•
Stops were improperly set
Stops need to be programmed.
2
Minor
System Fault
•
Obstruction present
•
Excessive system drag
Run bunk lift in opposite direction. If
bunk continues to move in the
opposite direction, remove
obstruction, excessive weight in bunk
or repair of damaged component. If
bunk stops moving in opposite
direction, observe fault code and
refer to this chart.
4
Major
Motor Fault
•
Bad wire connection
•
Bad motor
Refer to TIP Sheet 82-S0530 for
troubleshooting.
*
6
Minor
Excessive Battery Voltage
Supply voltage to control is 17 V
DC or greater.
Consult manufacturer of unit
charging system for troubleshooting
assistance.
1217 E. 7
th
St.
Mishawaka, IN 46544
www.powergearus.com
M1 = Motor 1
M2 = Motor 2
M1
M1
M1
M2
M2
M2
BUNK
BUNK
BUNK
Possible Bunk Lift Locations
Proper designation of motor locations
B
A
C
K
F
R
O
N
T
Road side
Curb side