background image

Power-Flo Pumps & Systems • 877-24PUMPS • www.powerflopumps.com

ISP No: PFSWC75 - 8/1/15

 

 

 

 

 

 

OWNER’S  MANUAL

Series: PFSWCPC75

3/4 HP • 1750 RPM • 60 Hz

Submersible Sewage Pump

Summary of Contents for PFSWCPC75

Page 1: ...Power Flo Pumps Systems 877 24PUMPS www powerflopumps com ISP No PFSWC75 8 1 15 OWNER S MANUAL Series PFSWCPC75 3 4 HP 1750 RPM 60 Hz Submersible Sewage Pump...

Page 2: ...approved 3 conductor cord and 3 prong grounded plug Do not remove the ground pin under any circumstances The 3 prong plug must be directly inserted into a properly installed and grounded 3 prong grou...

Page 3: ...tic 115V SJTW 16AWG 3C 230V SJTW 18AWG 3C 10 Ft cord with Piggy back plug On Off points are adjusteable Attaches to discharge piping WARRANTY 3 year MODEL HP Hz Volts Ph RPM FL AMPS Cord Length Wt PFS...

Page 4: ...Power Flo Pumps Systems 877 24PUMPS www powerflopumps com 4 Performance Dimensions PFSWCPC75Series Submersible Sewage Pumps Models PFSWCPC75201451F10 PFSWCPC75201452F10...

Page 5: ...ethered Mechanical Normally Open N O Reinforced thermoplastic 115V SJOW 16AWG 2C 230V SJOW 18AWG 2C 10 Ft cord w Piggy back plug On point 16 5 Off point 8 7 WARRANTY 3 year MODEL HP Hz Volts Ph RPM FL...

Page 6: ...Power Flo Pumps Systems 877 24PUMPS www powerflopumps com 6 PFSWCPC75Series Submersible Sewage Pumps Performance Dimensions Models PFSWCPC75201451T10 PFSWCPC75201452T10...

Page 7: ...inch solids The pump is built with overload thermal protections and auto reset The pump is equipped with a 3 prong grounding type power cord and tethered or vertical float switch This pump operates a...

Page 8: ...ord plug to be submerged Step 3 DO NOT use extension cords They are a fire hazard and can reduce voltage sufficiently to prevent pumping and or damage motor Step 4 DO NOT handle or service pump while...

Page 9: ...will void the warranty and may damage the pump An automatic overload protector in the motor will protect motor from burning out due to overheating overloading When motor cools down overload protector...

Page 10: ...pump and control switch Submerge pump in a disinfectant solution bleach for at least one hour before disassembling pump Put the pump upside down Note Pump is oil filled to void the oil leakage don t...

Page 11: ...Reposition the pump and make sure switch moves freely Pump operates but pumps little or no water 1 Debris caught in impeller or pipe 2 Check valve stuck or installed backward 3 Anti airlock hole bloc...

Page 12: ...tances including but not limited to the following sand gravel cement mud tar hydrocarbons hydrocarbon derivatives oil gasoline solvents etc or other abrasive or corrosive substances washtowelsorfemini...