![Power Fist 8717035 Instructions Manual Download Page 9](http://html1.mh-extra.com/html/power-fist/8717035/8717035_instructions-manual_1587204009.webp)
V1.0
115V Mini Utility Pump
8717035
Visit www.princessauto.com for more information
9
an authorized technician. Only use identical replacement parts
when servicing.
3.
Only use accessories intended for use with this device.
4.
Maintain the device’s labels and name plates. These carry important
information. If unreadable or missing, contact Princess Auto Ltd.
for replacements.
WARNING! Only qualified service personnel should repair the device. An
improperly repaired device may present a hazard to the user and/or others.
REPLACING THE MOTOR BRUSHES
IMPORTANT! Motor brushes (sold separately) wear out during regular use
and must be replaced periodically.
1.
Unscrew the brush caps (A) at the motor’s sides.
2. Remove the brushes and spring assemblies (B) by pulling them away
from the brush holders.
3.
Install the new brushes. Ensure they are properly aligned.
4.
Reinstall the spring assemblies and caps.
REPLACING THE IMPELLER
1.
Remove the face plate screws (C), face plate (F) and gasket (D).
2. Remove the damaged or worn impeller (G).
3.
Clean the interior surface of the pump cavity. Remove any foreign
objects to allow the impeller to turn freely.
4.
Apply a thin coat of light lubricant on the interior surface of the pump
cavity and the exterior surface of the new impeller.
5.
Align the impeller with the motor shaft. Push into place while rotating
the blades in a clockwise direction.
6. Reinstall the gasket, face plate and face plate screws.
CLEANING
Flush the pump with running water to remove debris or buildup.
LUBRICATION
Inspect and lubricate the device when required. Only use light oil to
lubricate the device. Other lubricants may not be suitable and could damage
the device or cause a malfunction during use.