Power Fist 8703159 User Manual Download Page 7

V4.0 

1-1/2 HP Totally Enclosed Air Over Electric Motor 

8703159 

Visit www.princessauto.com for more information 

ASSEMBLY & INSTALLATION 

MOUNTING  

Foot mounted: 

Foot mounted motors should be mounted to a rigid foundation 

to prevent excessive vibration. Shims may be used if the location is uneven.  

Flange mounted: 

Flange mounted motors should be properly seated and 

aligned. If improper rotation direction is detrimental to the load, check the 

rotation or ‘bump’ the motor prior to coupling the load to the motor shaft.  

V-belt drive: 

Mount the sheave pulley close to the motor housing. Allow 

clearance for end-to-end movement of the motor shaft. Do not over-tighten 

belts as this may cause premature bearing failure or shaft breakage.  

Direct coupled: 

Direct coupled motors should be carefully aligned and the shaft 

should rotate freely without binding or drag.  

BUILD A GUARD  

WARNING! Guards must be installed to form a safe and uncompromised 

perimeter around rotating parts such as couplings, pulleys, external fans 
and unused shaft extensions.  

After motor installation is complete, a guard of suitable dimensions must be 

constructed and installed around the motor. This guard must prevent personnel 

from coming in contact with any moving parts of the motor or drive assembly, but 

must allow sufficient cooling air to pass over the motor. If a motor mounted brake 

is installed, provide proper safeguards for personnel in case of brake failure.  
All parts should be permanently guarded to prevent accidental contact by personnel. 

Accidental contact with body parts or clothing can cause serious or fatal injury. 

When this motor is installed according to these instructions, it complies with the 

EEC Machinery Directive. Electromagnetic Compatibility (EMC) requirements for CE 

compliance are met when the incoming power is purely sinusoidal.  

ELECTRICAL INSTALLATION  

GROUNDING THE MOTOR  

Ground the motor according to CE and local codes. Consult the Canadian 

Electrical Code (CE) for information on grounding of motors and generators and 

Summary of Contents for 8703159

Page 1: ...V4 0 8703159 Please read and understand all instructions before use Retain this manual for future reference User Manual 1 1 2 HP Totally Enclosed Air Over Electric Motor...

Page 2: ...ion Type F Service Factor 1 4 Shaft Diameter 5 8 in Frame Type 56 Rotation Direction when facing the shaft Reversible Totally Enclosed Housing Yes Open Drip Proof Housing No Auto Overload Protection Y...

Page 3: ...personal injury or death if the proper precautions are not taken WARNING This notice indicates a specific hazard or unsafe practice that could result in severe personal injury or death if the proper p...

Page 4: ...clothing designed for the work environment and tool 4 Non skid footwear is recommended to maintain footing and balance in the work environment 5 Wear steel toe footwear or steel toe caps to prevent a...

Page 5: ...The Control of Hazardous energy lockout tag out 3 Connect Power and Ground to the motor according to the Canadian Electrical Code CE or IEC and local codes 4 Provide a permanent guard to prevent acci...

Page 6: ...eased chance of electrical shock if your body is grounded 3 Do not expose the tool to rain or wet conditions Water entering a power tool will increase the risk of electric shock 4 In the event of a po...

Page 7: ...a safe and uncompromised perimeter around rotating parts such as couplings pulleys external fans and unused shaft extensions After motor installation is complete a guard of suitable dimensions must b...

Page 8: ...observe this precaution could result in bodily injury Connect the motor as shown in the connection diagram on the motor nameplate Be sure to identify the proper wiring diagram for the motor you are i...

Page 9: ...qualified service personnel should repair the tool An improperly repaired tool may present a hazard to the user and or others CONDENSATE DRAINS The motor comes with one way sintered brass breather dr...

Page 10: ...e or circuit breaker is correct for the motor It should exceed the Motor s FLC by 25 percent 2 Let cool and then reset overloads Test the starter before starting motor again 3 Reset the thermal switch...

Page 11: ...ue is with the load attached to the motor Should the motor still not work have it serviced or replaced by a qualified technician 4 Begin by confirming all contacts are clean and tight Examine for obvi...

Page 12: ...motor to see if any parts are touching Check to see the motor s shaft is straight a Run the motor under normal load and check the amount of current it is drawing b Disconnect the motor from its load...

Page 13: ...V4 0 1 1 2 HP Totally Enclosed Air Over Electric Motor 8703159 Visit www princessauto com for more information 13...

Page 14: ...8703159 1 1 2 HP Totally Enclosed Air Over Electric Motor V4 0 14 For technical questions call 1 800 665 8685...

Page 15: ...us devez lire et comprendre toutes les instructions avant d utiliser l appareil Conservez ce manuel afin de pouvoir le consulter plus tard Manuel d utilisateur Moteur lectrique ventilation de 1 1 2CV...

Page 16: ...ervice 1 4 Diam tre de l arbre 5 8 po Type de ch ssis 56 Sens de rotation lorsqu on se trouve face l arbre R versible Bo tier totalement ferm Oui Bo tier ouvert abrit Non Protection automatique contre...

Page 17: ...a des blessures corporelles graves ou m me la mort si on omet de prendre les pr cautions n cessaires AVERTISSEMENT Cet avis indique un risque particulier ou une pratique non s curitaire qui pourrait e...

Page 18: ...s de gants lorsque vous utilisez un outil dans lequel le tissu pourrait demeurer coinc entra nant ainsi la main 3 Portez des v tements de protection con us pour l environnement de travail et pour l ou...

Page 19: ...taller d utiliser ou de proc der l entretien familiarisez vous avec les points suivants Publication NEMA MG 2 Norme de s curit dans la construction et guide de s lection d installation et d utilisatio...

Page 20: ...T EN LECTRICIT AVERTISSEMENT Ne touchez et ne manipulez pas un outil sous tension avec une partie du corps qui est mouill e ou humide La peau humide r duit la r sistance au courant lectrique augmentan...

Page 21: ...onctionner l outil si des pi ces sont manquantes Remplacez les pi ces manquantes avant l utilisation Le non respect de cet avertissement peut entra ner une d fectuosit et des blessures graves Retirez...

Page 22: ...tections appropri es pour le personnel en cas de bris du frein Toutes les pi ces doivent tre prot g es en permanence afin de pr venir tout contact accidentel par le personnel Un contact accidentel ave...

Page 23: ...ur la plaque signal tique du moteur Assurez vous d identifier le sch ma de c blage appropri qui correspond au moteur que vous installez Si vous avez de la difficult d terminer le sch ma de c blage qui...

Page 24: ...ss Auto Ltd pour les remplacer AVERTISSEMENT Seul un personnel d entretien qualifi doit effectuer la r paration de l outil l appareil Un outil appareil mal r par peut pr senter un risque pour l utilis...

Page 25: ...usible ou le disjoncteur V rifiez galement si la tension ou l intensit nominale du fusible ou du disjoncteur convient au moteur Celui ci devrait d passer le courant charge maximale du moteur de 25 2 L...

Page 26: ...is n atteint pas le moteur 1 V rifiez si la tension alimente le fusible ou le disjoncteur V rifiez galement si la tension ou l intensit nominale du fusible ou du disjoncteur convient au moteur Celui c...

Page 27: ...2 Un conducteur sous tension est branch au cadre du moteur 3 Surcharge du moteur encours de fonctionnement 1 Rebranchez ou remplacez le fil de masse et v rifiez si la mise la masse est efficace 2 Dem...

Page 28: ...our expulser les d bris par les orifices de ventilation Vibration ou bruit excessif 1 Jeu longitudinal excessif l int rieur du moteur 2 Roulements us s ou mal lubrifi s 1 Un moteur ou une charge en d...

Reviews: