Power Fist 8519209 User Manual Download Page 3

1/2 HP Stainless Steel Sewage Pump

Visit www.princessauto.com for more information 

3

8519209 

V 3.04

NOTE:

 Keep this manual for the safety warnings, precautions and operating, inspection and 

maintenance instructions.

Work Area

1.  Operate in a safe work environment. Keep your work area clean and well lit.

2.  Do not install in the presence of flammable gases or liquids.

3.  Keep anyone not wearing the appropriate safety equipment away from the work area.

4.  Always lock up tools and keep them out of the reach of children.

NOTE: 

Minimize distractions in the work environment. Distractions can cause you to lose control of  

the tool.

Personal Safety

CAUTION! Wear protective equipment approved by the Canadian Standards Association (CSA) or 

American National Standards Institute (ANSI) when using the tool.

1.  Dress properly, wear protective equipment. Use breathing, ear, eye, face, foot, hand and 

head protection. Always wear ANSI approved impact safety goggles, which must provide 

both frontal and side protection. Protect your hands with suitable gloves. Protect your head 

from falling objects by wearing a hard hat. Wear an ANSI approved dust mask or respirator 

when working around chemical dusts and mists. Wear ANSI approved earplugs. Protective, 

electrically non-conductive clothes and non-skid footwear are recommended when working. 

Wear steel-toed boots to prevent injury from falling objects.

2.  Control the tool, personal movement and the work environment to avoid personal injury or 

damage to the tool. Stay alert, watch what you are doing and use your common sense.

3.  Keep articles of clothing, jewelry, hair, etc., away from moving parts to avoid entanglement 

with a tool.

4.  Do not operate any machine / tool when tired or under the influence of drugs, alcohol 

or medications.

5.  Do not overreach when operating a tool. Proper footing and balance enables better control in 

unexpected situations.

SPECIFIC SAFETY PRECAUTION

WARNING! The pump motor is equipped with an automatic resetting thermal protector and may 

restart unexpectedly.

1.  Wear safety glasses when working with pumps.

2.  Do not run the pump if there is no water in the system.

3.  Do not power this device with anything other than a 115 volt power source.

4.  Connect this product to a grounded circuit equipped with a Ground Fault Circuit Interrupter 

(GFCI) device.

5.  Vent sewage or septic tank according to local codes.

6.  Do not install the pump in any location classified as hazardous by the National Electrical 

Code, ANSI / NFPA 80-1984 or the Canadian Electrical Code.

7.  Be sure that construction and access to septic sumps conform with all OSHA requirements.

8.  Risk of fire or explosion. Do not pump flammable or explosive fluids such as gasoline, fuel 

oil, kerosene, etc.

9.  Do not use in a flammable and / or explosive environment.

Summary of Contents for 8519209

Page 1: ...User Manual V 3 04 8519209 Please read and understand all instructions before use Retain this manual for future reference 1 2 HP Stainless Steel Sewage Pump...

Page 2: ...1 300 gallons per hour Flow Rate 20 Feet 700 gallons per hour Float Switch Vertical Cord Length 10 feet CUL CUL 248578 IMPORTANT SAFETY PRECAUTIONS WARNING Read and understand all instructions before...

Page 3: ...otwear are recommended when working Wear steel toed boots to prevent injury from falling objects 2 Control the tool personal movement and the work environment to avoid personal injury or damage to the...

Page 4: ...prevent pumping and or damage the motor 4 Do not handle or service the pump while it is connected to the power supply 5 Do not remove the grounding prong from the plug or modify the plug To protect a...

Page 5: ...CAUTION The motor housing transfers heat to the volute This pump is capable of operating with the motor housing partially exposed for extended periods while still providing sufficient motor cooling an...

Page 6: ...2 HP Stainless Steel Sewage Pump 6 For technical questions call 1 800 665 8685 V 3 04 8519209 Pump on level 7 to 8 in 18 cm to 20 32 cm Pump off level 4 to 5 in 10 cm to 13 cm TYPICAL INSTALLATION Fig...

Page 7: ...l power source to the pump and the control switch Do not lift the pump by the power cord WARNING Sudden starts If the power is on to the pump when the thermal overload resets the pump may start withou...

Page 8: ...ump does not turn on The pump is not plugged in Plug in the pump Circuit breaker shutoff or the fuse is removed Turn on the circuit breaker or replace the fuse Accumulation of buildup on the float Cle...

Page 9: ...mp from service and clean The pump is air locked Shut the power off for approximately 1 minute then restart the pump Repeat several times to clear the air from the pump The pump does not deliver the r...

Page 10: ......

Page 11: ...e et comprendre toutes les instructions avant d utiliser l appareil Conservez ce manuel afin de pouvoir le consulter plus tard Manuel d utilisateur V 3 04 8519209 Pompe pour eaux us es en acier inoxyd...

Page 12: ...dable Mat riau d impulseur Fonte D bit 5 pi 2 500 gal h D bit 10 pi 2 000 gal h D bit 15 pi 1 300 gal h D bit 20 pi 700 gal h Interrupteur flotteur Vertical Longueur du cordon 10 pi CUL CUL 248578 CON...

Page 13: ...protection Utilisez des protections pour les voies respiratoires les oreilles les yeux le visage les pieds les mains et la t te Portez toujours des lunettes de s curit tanches approuv es par l ANSI q...

Page 14: ...est identique 14 N exposez pas la pompe aux temp ratures de cong lation Le gel pourrait causer des dommages graves ce qui annulera la garantie 15 N introduisez pas de doigt ou d objet dans les orifice...

Page 15: ...n pr sence d quipement lectrique vitez que le corps entre en contact avec des surfaces mises la terre Il y a un risque plus lev de choc lectrique si votre corps est mis la terre AVERTISSEMENT Un lectr...

Page 16: ...UE Ne placez jamais la pompe directement sur des surfaces d argile de terre ou de gravier 2 Installez la pompe au moyen d un tuyau en ABS en PVC en poly thyl ne ou en acier galvanis Utilisez les bons...

Page 17: ...un couvercle scell vous ne pouvez observer le fonctionnement de l interrupteur flotteur Ce couvercle pr sentera habituellement un orifice de r serve qui est bouch au moyen d un bouchon de caoutchouc E...

Page 18: ...mpe de la source d nergie avant de proc der l entretien REMARQUE Cette pompe n est munie d aucune pi ce dont on peut proc der l entretien Le carter de moteur de la pompe est compl tement scell et ne d...

Page 19: ...pendant environ 1 minute et red marrez ensuite la pompe Recommencez plusieurs reprises afin d vacuer l air de la pompe L arriv e de liquide a atteint la capacit de la pompe Une pompe de capacit sup ri...

Page 20: ...r vous assurer qu elle correspond la tension indiqu e sur la plaque signal tique Le centrifugeur ou le tuyau de refoulement est ferm Enlevez la pompe afin de proc der son entretien et son nettoyage La...