CLEANING
Check the manufacturer of the fluid for cleaning instructions to make sure
the cleaning solution used is compatible. The cleaning solution will become
contaminated with the original fluid pumped and may require special
disposal procedures.
DISPOSAL
Recycle a tool damaged beyond repair at the appropriate facility.
Contact your local municipality for a list of disposal facilities or by-laws for
electronic devices, batteries, oil or other toxic liquids.
IMPORTANT! DO NOT pollute the environment by allowing uncontrolled
discharge of waste oil.
TROUBLESHOOTING
Visit a Princess Auto Ltd. location for a solution if the tool does not function
properly or parts are missing. If unable to do so, have a qualified technician
service the tool.
Problem(s)
Possible Cause(s)
Suggested Solution(s)
Pump does not
dispense fluid.
1. Pump is drawing in air,
instead of fluid.
2. Suction tube inlet is
blocked.
1. Tighten all connections of
the suction tube and of the
suction tube at the pump
inlet.
2. Remove the suction tube and
clean the strainer at the tube
inlet.
Tool runs slowly.
Air flows slightly
from exhaust.
Airflow blocked by dirt.
1. Check air inlet filter for
blockage.
2. Operate tool in short bursts
to clear debris.
3. If tool still jammed, clean tool
and lubricate per lubrication
instructions.
Tool runs slowly.
Air flows slightly
from exhaust.
1. Air regulator in closed
position.
2. Damage or excessive
wearing of internal parts.
1. Open the air regulator to
desired airflow.
2a. Have a qualified technician
service the tool.
2b. Replace tool or parts.