DESCRIPTION OF PROGRAMMING PARAMETERS
Screen Description Default
value
Range
Function
Set
on
RUN
bA.34
Auto tuning
level for Ld
and Lq
33.3% 20.0 to 50.0%
Adjusts the autotuning level for Ld (active
energy axis) and Lq (reactive energy axis), for
the synchronous motors permanant magnet
motor control.
Note:
Visible parameter if dr.9 = PM Sensor-
less
NO
bA.35
Frecuencia
de autoajuste
para Ld y Lq
100.0% 80.0
–
150.0%
Adjusts the frequency of autotuning for Ld
(active energy axis) and Lq (reactive energy
axis), for the synchronous motors permanant
magnet motor control.
Note:
Visible parameter if dr.9 = PM Sensor-
less
NO
bA.41
[4]
User
Frequency 1 1500Hz 0.00 to dr.20
Set user frequency 1. When the output
frequency reaches this value, the drive will
provide the voltage set in parameter bA.42.
NO
bA.42
User Voltage
1
25%
0 to 100%
Set user voltage 1. The drive will provide the
frequency set in parameter when the
frequency configured in bA.41 is reached.
NO
bA.43
User
Frequency 2
3000Hz 0.00 to dr.20
Set user frequency 2. When the output
frequency reaches this value, the drive will
provide the voltage set in parameter bA.44.
NO
bA.44
User Voltage
2
50%
0 to 100%
Set user voltage 2. The drive will provide the
frequency set in parameter when the
frequency configured in bA.43 is reached.
NO
bA.45
User
Frequency 3 4500Hz 0.00 to dr.20
Set user frequency 3. When the output
frequency reaches this value, the drive will
provide the voltage set in parameter bA.46.
NO
bA.46
User Voltage
3
75%
0 to 100%
Set user voltage 3. The drive will provide the
frequency set in parameter when the
frequency configured in bA.45 is reached.
NO
bA.47
User
Frequency 4 000Hz 0.00 to dr.20
Set user frequency 4. When the output
frequency reaches this value, the drive will
provide the voltage set in parameter bA.48.
NO
[4] These parameters will only be displayed if bA.7 or M2.25 are set to 2 (V/F Us).
Summary of Contents for SD 300 Series
Page 1: ...SD300 GETTING STARTED MANUAL LOW VOLTAGE VARIABLE SPEED DRIVE ...
Page 2: ......
Page 3: ...Variable Speed Drive Getting Started Manual Edition February 2019 SD30IM01GI Rev G ...
Page 159: ...POWER ELECTRONICS SD300 DESCRIPTION OF PROGRAMMING PARAMETERS 157 Power off delay ...
Page 174: ...SD300 POWER ELECTRONICS 172 DESCRIPTION OF PROGRAMMING PARAMETERS TI configuration ...
Page 352: ......
Page 353: ......