Power Bright PW1500-12 User Manual Download Page 3

                   WARNINGS: INVERTER OUTPUT 

                  This is a heavy-duty device that produces voltages similar to        
                   commercial AC power.  

  Danger of shock or electrocution - treat inverter output the same 

as commercial AC power.  

  Do not use the inverter near flammable materials or in any 

locations that may accumulate flammable fumes or gases. This 
is an electrical device that can briefly spark when electrical 
connections are made or broken. 

  Do not allow water or other liquids to contact the inverter. 

  Do not use appliances with damaged or wet cords. 

 

                   CAUTIONS: INVERTER OPERATING ENVIROMENT 

        Surrounding air temperature should be between -20°C and       

        40°C – ideally between 15°C and 25°C (60 - 80°F).  

  Keep the inverter away from direct sunlight, if at all possible. 

  Keep the area surrounding the inverter clear to ensure free air 

circulation around the unit. Do not place items on or over the 
inverter during operation. The unit will shut down if the internal 
temperature gets too hot. Restart the inverter after it cools.  

 This 

PowerBright

TM

 inverter will only operate from a 12V power 

source. Do not attempt to connect the inverter to any other 
power source, including any AC power source 

  Do not reverse DC input polarity – this will void the warranty. 

 

                   APPLIANCE CAUTIONS 

        DO NOT plug in battery chargers for cordless power tools if    

        the charger carries a warning that dangerous voltages are 

present at the battery terminals. 

  Certain chargers for small nickel-cadmium or nickel-metal-

hydride batteries can be damaged if powered by this inverter. 
Two types of appliances are susceptible to damage: Small, 
battery-operated appliances such as flashlights, cordless razors 
and toothbrushes that plug directly into an AC receptacle. 

  DO NOT use this inverter with the above two types of equipment. 

  The majority of portable appliances do not have this problem. 

Most portable appliances use separate transformers or chargers 
that plug into AC receptacles to supply a low-voltage DC or AC 

Summary of Contents for PW1500-12

Page 1: ......

Page 2: ...BrightTM PW1500 12 PW2300 12 will operate a particular appliance or a combination of appliances run a test All inverters are designed to automatically shut down in the event of a power overload This p...

Page 3: ...g operation The unit will shut down if the internal temperature gets too hot Restart the inverter after it cools This PowerBrightTM inverter will only operate from a 12V power source Do not attempt to...

Page 4: ...monitor the temperature of the battery charger for approximately 10 minutes If the battery charger becomes abnormally warm immediately disconnect it from the inverter WARNING DANGER OF BATTERY EXPLOS...

Page 5: ...terms of power requirements You will need to determine how much power your tool or appliance requires to start up starting load and it s continued running power requirements continuous load Power cons...

Page 6: ...xceeds 1500 watts 2300 watts this light will turn ORANGE RED and the inverter will automatically shut down When this occurs turn off the inverter and determine the cause of the overload before turning...

Page 7: ...nd any DC appliances powered by the battery bank Follow these steps 1 List the maximum wattage that the inverter has to provide as above 2 Estimate the number of hours the appliances will be in use be...

Page 8: ...h power inverter is important Operating a high power inverter will routinely discharge batteries and they will require frequent recharging Batteries used to start engines are not designed to repeatedl...

Page 9: ...in the following procedure minimizes the danger of sparking near the battery bank 1 Prepare all cable set ends with ring terminals at the battery ends 2 Install one fuse holder with fuse on the Pos c...

Page 10: ...and filtered to minimize signal interference some interference with your television picture may be unavoidable especially in weak signal areas Here are some suggestions that may improve reception 1 F...

Page 11: ...n is a modified sine wave as shown in the diagram below a pure sine wave Consequently most meters will not read the RMS outpvoltage of the inverter use any multimeter identified as True RM Best Use Of...

Page 12: ...k for adequate ventilation Re duce the load on the inverter to rated continuous power Unit may be defective See warranty and call customer service PROBLEM Low Battery Alarm on all the time Reason Solu...

Page 13: ...h OFF 0 5 ADC Battery low alarm 10 5 0 5 V DC Battery low shutdown 10 0 5 V DC AC output sockets 2 North American Standard 15 amps Internal fuses 6 x 25 Amp spade type Fuses 8 x 25 Amp spade type Fuse...

Page 14: ...cident in shipment unreasonable use misuse neglect improper service commercial use repairs by unauthorized personnel or other causes not arising out of defects in materials or workmanship This warrant...

Page 15: ...ge de puissance Cette protection emp che d endommager l onduleur ainsi que vos appareils Branchez l appareille avec la plus haute puissance d abord puis les autres appareils Si une combinaison d appar...

Page 16: ...polarit d entr e DC ce ci annulera la garantie MISES EN GARDE APPAREIL Ne pas brancher les chargeurs de batterie pour outils lectriques sans fil si le chargeur est passible d une mise en garde que de...

Page 17: ...recommande d installer un fusible de type ANL connecter au c ble positif de la batterie Ce Fusible prot ge les piles contre les cours circuit des c bles DC qui peuvent causer les piles exploser Les f...

Page 18: ...u il peut tre calcul e partir d amp res amp res Cette information est habituellement estampill e ou imprim sur la plupart des appareils et quipements Si cette information n est pas indiqu e sur l appa...

Page 19: ...puissance continue de l appareil s d passe 1500 watts 2300 watts ce feu passera ORANGE ROUGE et l onduleur s arr tera automatiquement Lorsque cela se produit teignez l onduleur et d terminer la cause...

Page 20: ...ts Le courant amp res est la suivante 2000 10 200 amp res 12 V DC Ajouter la charge toute appareils tre aliment par la banque de batterie Le calibrage de la batterie Pour d terminer le minimum amp re...

Page 21: ...nt pas con ues plusieurs reprises de charge et de d charge PowerBrightTM recommande l utilisation de Charge Profonde ou marines L paisseur des C bles Lorsque vous connectez l onduleur une batterie Si...

Page 22: ...Branchez le c ble n gatif l onduleur au borne n gatif de l onduleur 8 Isolez les deux extr mit s de c bles tre connect s au terminaux POS de l onduleur 9 Connectez le c ble positif au bornes Positif d...

Page 23: ...ur la t l vision 4 Bobiner le cordon d alimentation de la t l vision et les c bles d entr e 12 volts qui alimente l onduleur 5 connecter une Filtre Ferrite au cordon d alimentation de la t l vision Pl...

Page 24: ...aux solaires ou oliennes Ne laissez pas les batteries au plomb acide rester cong di pour de longues p riodes de temps ils perdent de la capacit amp res heures Proposition 65 de la Californie sur l lim...

Page 25: ...rer vous d avoir une ventilation ad quate r duire la charge la puissance nominale continue Unit peut tre d fectueuse Consulter notre garantie et appeler notre service a la client le PROBLEME alarme de...

Page 26: ...pas de charge 0 15 ADC Alarme de Batterie faible 10 5 0 5 V DC Arr t Batterie faible 10 0 5 V DC AC 4 prises de courant 2 standard Nord Am ricain 15 amp res Fusible interne 6 x 25 Amp spade type Fuses...

Page 27: ...tructions crites fournies ou si le produits a t endommag par accident en cours d exp dition utilisation d raisonnable utilisation abusive n gligence l utilisation commerciale par des r parations de pe...

Page 28: ......

Reviews: